title: "SMA America: STP 50-US-41 {480V} Inverter (50,000W)"
url: https://epri-peac.com/solar-equipment/inverters/sma-america/sma-america-stp-50-us-41-480v/
description: "CEC specs for SMA America: STP 50-US-41 {480V}: 50,000W AC, 480V, 80A OCPD, and NEC 705.12 checks. Verified US government and CEC engineering data."
---

CEC Grid-Support Inverter

# SMA America: STP 50-US-41 {480V} — CEC Inverter Specifications

Manufacturer: [**SMA America**](https://epri-peac.com/solar-equipment/brands/sma-america/) Registry: **CEC Verified Engineering Specification**

SMA America: STP 50-US-41 {480V} outputs 50,000 W AC at 480 V, 3-phase (60.1 A continuous, 80 A OCPD), ranking #576 of 2,343 CEC inverters at 97.43% efficiency with a 500-800 V MPPT window and 800 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 50,000 W

- **AC Voltage** : 480 V, 3-phase

- **Min PV Breaker** : 80 A (4 AWG Cu)

- **CEC Efficiency** : 97.43%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does SMA America: STP 50-US-41 {480V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 480 V, 3-phase grid-support overview for SMA America: STP 50-US-41 {480V}.

Rated at 50,000 W AC (60.1 A continuous), SMA America: STP 50-US-41 {480V} ranks #576 of 2,343 CEC units at 97.43% efficiency (-0.59 pts vs the 98.02% 480 V median). Minimum 75 C copper conductor sizing for its 80 A circuit is 4 AWG Cu per NEC Table 310.16. Cold-weather string Voc must remain under 800 V DC at record local winter lows.

## Where Does SMA America: STP 50-US-41 {480V} Fall Across Listed CEC Models?

Marks SMA America: STP 50-US-41 {480V} (50,000 W AC) across the California Energy Commission inverter AC capacity distribution.

## What Dataset Percentiles Define SMA America: STP 50-US-41 {480V}?

Benchmarks SMA America: STP 50-US-41 {480V} continuous AC output, 97.43% CEC weighted efficiency, and 80 A OCPD breaker demand.

## What Do the Dataset Ranks Show for SMA America: STP 50-US-41 {480V}?

Four key NEC 705.12 and California Energy Commission metrics defining SMA America: STP 50-US-41 {480V} by SMA America.

Eff #576 / 2,343

### 97.43% CEC Weighted Efficiency

-0.59 pts vs the 98.02% 480 V median; overall power rank #438 (50,000 W, top 19.3%; higher than 80.7% of peers).

NEC 705.12 Check

### 80 A Required Backfeed OCPD

125% x 60.1 A = 75.1 A -> 80 A standard OCPD using 4 AWG Cu (75 C).

MPPT Window

### 500 V - 800 V (Max 800 V DC)

Tracking span of 300.0 V; listed since 2022-11-01 (grid-tied PV inverter).

Commercial / 3-Phase Fit

### PASS (120% Commercial Busbar)

Evaluated for 480 V, 3-phase switchgear (200A Bus / 200A Main (480V) to 1,200A Bus / 1,200A Main (480V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 50000.0W / 480 V 3-phase -> 60.1 A | Breaker >= 1.25 * 60.1 = 75.1 A -> 80 A

CEC Inverters.csv for SMA America: STP 50-US-41 {480V}: Paco=50000.0 W, Vac=480 V, Vdcmax=800.0 V, Eff=97.43%.

**Result:** Min 80 A breaker & 4 AWG Cu (75 C); 1,200A Bus / 1,200A Main (480V): PASS (120% Commercial Busbar).

## What Are the Published CEC Specifications for SMA America: STP 50-US-41 {480V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for SMA America: STP 50-US-41 {480V}.

Official California Energy Commission (NREL SAM) test parameters for SMA America: STP 50-US-41 {480V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 50,000 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 480 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 800 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 500 V - 800 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 70.7829 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 97.43% | Calculated AC/DC conversion ratio from CEC test protocol |
| **CEC Listing Date & Hybrid** | 2022-11-01 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |

## What Switchgear Limits Apply to SMA America: STP 50-US-41 {480V} (480 V, 3-phase)?

Evaluates SMA America: STP 50-US-41 {480V} (80 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates SMA America: STP 50-US-41 {480V} (80 A required OCPD at 480 V, 3-phase) across standard distribution busbars.

| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **200A Bus / 200A Main (480V)** | 40 A | 80 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **400A Bus / 400A Main (480V)** | 80 A | 80 A | PASS (120% Commercial Busbar) |
| **600A Bus / 600A Main (480V)** | 120 A | 80 A | PASS (120% Commercial Busbar) |
| **800A Bus / 800A Main (480V)** | 160 A | 80 A | PASS (120% Commercial Busbar) |
| **1,200A Bus / 1,200A Main (480V)** | 240 A | 80 A | PASS (120% Commercial Busbar) |

## Which CEC PV Module Strings Pair With SMA America: STP 50-US-41 {480V}?

Sample PV string lengths aligned within 500-800 V MPPT and 800 V DC max at -10 C. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Sampled CEC PV modules aligned within 500.0-800.0 V MPPT and 800.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 12 to 14 panels | 8.26 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 15 to 18 panels | 7.92 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 15 to 17 panels | 7.22 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 18 to 19 panels | 3.8 kW |

## Which Competing Grid-Support Inverters Compare to SMA America: STP 50-US-41 {480V}?

Competing CEC grid-support inverters near 50,000 W AC and 480 V, 3-phase, led by ABB: TRIO-500-TL-OUTD-US-480 {480V}. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**ABB: TRIO-500-TL-OUTD-US-480 {480V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-trio-500-tl-outd-us-480-480v/) ABB | 50,000 W | Tie (0 W) | 480.0 V | 800.0 V | 98.27% |
| [**Canadian Solar Inc: CSI-50KTL-CT {480V}**](https://epri-peac.com/solar-equipment/inverters/canadian-solar-inc/canadian-solar-inc-csi-50ktl-ct-480v/) Canadian Solar Inc | 50,000 W | Tie (0 W) | 480.0 V | 850.0 V | 98.36% |
| [**Canadian Solar Inc: CSI-50KTL-GS {480V}**](https://epri-peac.com/solar-equipment/inverters/canadian-solar-inc/canadian-solar-inc-csi-50ktl-gs-480v/) Canadian Solar Inc | 50,000 W | Tie (0 W) | 480.0 V | 720.0 V | 98.43% |
| [**Canadian Solar Inc: CSI-50KTL-GS-FL {480V}**](https://epri-peac.com/solar-equipment/inverters/canadian-solar-inc/canadian-solar-inc-csi-50ktl-gs-fl-480v/) Canadian Solar Inc | 50,000 W | Tie (0 W) | 480.0 V | 720.0 V | 98.47% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for SMA America: STP 50-US-41 {480V}?

Check SMA America: STP 50-US-41 {480V} (50,000 W AC, 80 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 800 V DC on SMA America: STP 50-US-41 {480V}.

### SMA America: STP 50-US-41 {480V} Panel & Wire Spec

Size 75 C copper conductors at 4 AWG Cu on an 80 A OCPD breaker (60.1 A continuous).

### Alternative Inverter Comparison

Compare efficiency (97.43%) and MPPT window (500-800 V) directly against ABB: TRIO-500-TL-OUTD-US-480 {480V} (50,000 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for SMA America: STP 50-US-41 {480V} by SMA America covering breaker sizing, MPPT limits, and 480 V, 3-phase interconnection.

### What breaker and wire size does SMA America: STP 50-US-41 {480V} require?

At 50,000 W continuous AC (480 V, 3-phase), continuous current is 60.1 A; 125% NEC 690.8/705.12 sizing requires an 80 A breaker and 4 AWG Cu (75 C) wire.

### What commercial switchgear or feeder sizing does SMA America: STP 50-US-41 {480V} require?

At 50,000 W AC and 480 V, 3-phase, continuous line current is 60.1 A, requiring an 80 A OCPD and 1,200A Bus / 1,200A Main (480V) or NEC 705.11 interconnection.

### How does SMA America: STP 50-US-41 {480V} compare to ABB: TRIO-500-TL-OUTD-US-480 {480V}?

SMA America: STP 50-US-41 {480V} delivers 50,000 W AC at 97.43% CEC efficiency with a 800 V DC ceiling, while ABB: TRIO-500-TL-OUTD-US-480 {480V} outputs 50,000 W at 480 V, 3-phase.

## Related Pages

Explore SMA America hardware, ABB: TRIO-500-TL-OUTD-US-480 {480V}, utility rates, and NEC 705.12 sizing calculators alongside SMA America: STP 50-US-41 {480V}.

[All SMA America Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/sma-america/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From SMA America

- [All SMA America Specs](https://epri-peac.com/solar-equipment/brands/sma-america/)
- [SMA America: SC 4600 UP-US 690V 3850A {690V}](https://epri-peac.com/solar-equipment/inverters/sma-america/sma-america-sc-4600-up-us-690v-3850a-690v/)
- [SMA America: SC 4400 UP-US 660V 3850A {660V}](https://epri-peac.com/solar-equipment/inverters/sma-america/sma-america-sc-4400-up-us-660v-3850a-660v/)
- [SMA America: SC 4200 UP-US 630V 3850A {630V}](https://epri-peac.com/solar-equipment/inverters/sma-america/sma-america-sc-4200-up-us-630v-3850a-630v/)
- [SMA America: SC 4000 UP-US 600V 3850A {600V}](https://epri-peac.com/solar-equipment/inverters/sma-america/sma-america-sc-4000-up-us-600v-3850a-600v/)
- [SMA America: SC 3060 UP-US 690V 2566A {690V}](https://epri-peac.com/solar-equipment/inverters/sma-america/sma-america-sc-3060-up-us-690v-2566a-690v/)