---
title: "SMA America: SHP FLEX-US-21 {660V} Inverter (172,810W)"
url: https://epri-peac.com/solar-equipment/inverters/sma-america/sma-america-shp-flex-us-21-660v/
description: "CEC specs for SMA America: SHP FLEX-US-21 {660V}: 172,810W AC, 660V, 200A OCPD, and NEC 705.12 checks. Verified US government and CEC engineering data."
---

CEC Grid-Support Inverter

# SMA America: SHP FLEX-US-21 {660V} — CEC Inverter Specifications

Manufacturer: [**SMA America**](https://epri-peac.com/solar-equipment/brands/sma-america/) Registry: **CEC Verified Engineering Specification**

SMA America: SHP FLEX-US-21 {660V} outputs 172,810 W AC at 660 V, 3-phase (151.2 A continuous, 200 A OCPD), ranking #60 of 2,343 CEC inverters at 98.57% efficiency with a 968-1,200 V MPPT window and 1,200 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 172,810 W

- **AC Voltage** : 660 V, 3-phase

- **Min PV Breaker** : 200 A (3/0 AWG Cu)

- **CEC Efficiency** : 98.57%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does SMA America: SHP FLEX-US-21 {660V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 660 V, 3-phase grid-support overview for SMA America: SHP FLEX-US-21 {660V}.

Ranking #260 of 2,343 CEC inverters (top 11.1%; higher than 88.9% of peers), SMA America: SHP FLEX-US-21 {660V} is a grid-tied PV inverter delivering 172,810 W continuous AC at 660 V, 3-phase (151.2 A continuous). Commercial 660 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (660V) or NEC 705.11 supply-side tap. Weighted CEC efficiency reaches 98.57% (+0.36 pts vs the 98.21% 660 V median) against peers like KACO new energy GmbH: KACO blueplanet 150 TL3 M1 WM OD IIQ0 {660V} (151,228 W).

## Where Does SMA America: SHP FLEX-US-21 {660V} Fall Across Listed CEC Models?

Marks SMA America: SHP FLEX-US-21 {660V} (172,810 W AC) across the California Energy Commission inverter AC capacity distribution.

## What Dataset Percentiles Define SMA America: SHP FLEX-US-21 {660V}?

Benchmarks SMA America: SHP FLEX-US-21 {660V} continuous AC output, 98.57% CEC weighted efficiency, and 200 A OCPD breaker demand.

## What Do the Dataset Ranks Show for SMA America: SHP FLEX-US-21 {660V}?

Four key NEC 705.12 and California Energy Commission metrics defining SMA America: SHP FLEX-US-21 {660V} by SMA America.

Eff #60 / 2,343

### 98.57% CEC Weighted Efficiency

+0.36 pts vs the 98.21% 660 V median; overall power rank #260 (172,810 W, top 11.1%; higher than 88.9% of peers).

NEC 705.12 Check

### 200 A Required Backfeed OCPD

125% x 151.2 A = 189.0 A -> 200 A standard OCPD using 3/0 AWG Cu (75 C).

MPPT Window

### 968 V - 1,200 V (Max 1,200 V DC)

Tracking span of 232.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

### Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 660 V, 3-phase switchgear (200A Bus / 200A Main (660V) to 1,200A Bus / 1,200A Main (660V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 172810.0W / 660 V 3-phase -> 151.2 A | Breaker >= 1.25 * 151.2 = 189.0 A -> 200 A

CEC Inverters.csv for SMA America: SHP FLEX-US-21 {660V}: Paco=172810.0 W, Vac=660 V, Vdcmax=1200.0 V, Eff=98.57%.

**Result:** Min 200 A breaker & 3/0 AWG Cu (75 C); 1,200A Bus / 1,200A Main (660V): PASS (120% Commercial Busbar).

## What Are the Published CEC Specifications for SMA America: SHP FLEX-US-21 {660V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for SMA America: SHP FLEX-US-21 {660V}.

Official California Energy Commission (NREL SAM) test parameters for SMA America: SHP FLEX-US-21 {660V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 172,810 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 660 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 1,200 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 968 V - 1,200 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 160.995 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 98.57% | Calculated AC/DC conversion ratio from CEC test protocol |
| **Inverter Topology** | Hybrid: No (Grid-Tied PV) | CEC Solar Equipment List grid-support certification |

## What Switchgear Limits Apply to SMA America: SHP FLEX-US-21 {660V} (660 V, 3-phase)?

Evaluates SMA America: SHP FLEX-US-21 {660V} (200 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates SMA America: SHP FLEX-US-21 {660V} (200 A required OCPD at 660 V, 3-phase) across standard distribution busbars.

| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **200A Bus / 200A Main (660V)** | 40 A | 200 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **400A Bus / 400A Main (660V)** | 80 A | 200 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **600A Bus / 600A Main (660V)** | 120 A | 200 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **800A Bus / 800A Main (660V)** | 160 A | 200 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **1,200A Bus / 1,200A Main (660V)** | 240 A | 200 A | PASS (120% Commercial Busbar) |

## Which Competing Grid-Support Inverters Compare to SMA America: SHP FLEX-US-21 {660V}?

Competing CEC grid-support inverters near 172,810 W AC and 660 V, 3-phase, led by KACO new energy GmbH: KACO blueplanet 150 TL3 M1 WM OD IIQ0 {660V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**KACO new energy GmbH: KACO blueplanet 150 TL3 M1 WM OD IIQ0 {660V}**](https://epri-peac.com/solar-equipment/inverters/kaco-new-energy-gmbh/kaco-new-energy-gmbh-kaco-blueplanet-150-tl3-m1-wm-od-iiq0-660v/) KACO new energy GmbH | 151,228 W | -21582 W | 660.0 V | 1300.0 V | 98.78% |
| [**KACO new energy GmbH: KACO blueplanet 150 TL3 M1 WM OD IIQX {660V}**](https://epri-peac.com/solar-equipment/inverters/kaco-new-energy-gmbh/kaco-new-energy-gmbh-kaco-blueplanet-150-tl3-m1-wm-od-iiqx-660v/) KACO new energy GmbH | 151,228 W | -21582 W | 660.0 V | 1300.0 V | 98.78% |
| [**EPC Power Corp: 50-200100 {660V}**](https://epri-peac.com/solar-equipment/inverters/epc-power-corp/epc-power-corp-50-200100-660v/) EPC Power Corp | 515,072 W | +342262 W | 660.0 V | 1500.0 V | 98.47% |
| [**INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1715TL U B660 {660V}**](https://epri-peac.com/solar-equipment/inverters/ingeteam-power-technology-sa/ingeteam-power-technology-sa-ingecon-sun-1715tl-u-b660-660v/) INGETEAM POWER TECHNOLOGY SA | 1,390,614 W | +1217804 W | 660.0 V | 1200.0 V | 97.22% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for SMA America: SHP FLEX-US-21 {660V}?

Check SMA America: SHP FLEX-US-21 {660V} (172,810 W AC, 200 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 660 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (660V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,200 V DC on SMA America: SHP FLEX-US-21 {660V}.

### SMA America: SHP FLEX-US-21 {660V} Panel & Wire Spec

Size 75 C copper conductors at 3/0 AWG Cu on a 200 A OCPD breaker (151.2 A continuous).

### Alternative Inverter Comparison

Compare efficiency (98.57%) and MPPT window (968-1,200 V) directly against KACO new energy GmbH: KACO blueplanet 150 TL3 M1 WM OD IIQ0 {660V} (151,228 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for SMA America: SHP FLEX-US-21 {660V} by SMA America covering breaker sizing, MPPT limits, and 660 V, 3-phase interconnection.

### What breaker and wire size does SMA America: SHP FLEX-US-21 {660V} require?

At 172,810 W continuous AC (660 V, 3-phase), continuous current is 151.2 A; 125% NEC 690.8/705.12 sizing requires a 200 A breaker and 3/0 AWG Cu (75 C) wire.

### What commercial switchgear or feeder sizing does SMA America: SHP FLEX-US-21 {660V} require?

At 172,810 W AC and 660 V, 3-phase, continuous line current is 151.2 A, requiring a 200 A OCPD and 1,200A Bus / 1,200A Main (660V) or NEC 705.11 interconnection.

### How does SMA America: SHP FLEX-US-21 {660V} compare to KACO new energy GmbH: KACO blueplanet 150 TL3 M1 WM OD IIQ0 {660V}?

SMA America: SHP FLEX-US-21 {660V} delivers 172,810 W AC at 98.57% CEC efficiency with a 1,200 V DC ceiling, while KACO new energy GmbH: KACO blueplanet 150 TL3 M1 WM OD IIQ0 {660V} outputs 151,228 W at 660 V, 3-phase.

## Related Pages

Explore SMA America hardware, KACO new energy GmbH: KACO blueplanet 150 TL3 M1 WM OD IIQ0 {660V}, utility rates, and NEC 705.12 sizing calculators alongside SMA America: SHP FLEX-US-21 {660V}.

[All SMA America Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/sma-america/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From SMA America

- [All SMA America Specs](https://epri-peac.com/solar-equipment/brands/sma-america/)
- [SMA America: SC 4600 UP-US 690V 3850A {690V}](https://epri-peac.com/solar-equipment/inverters/sma-america/sma-america-sc-4600-up-us-690v-3850a-690v/)
- [SMA America: SC 4400 UP-US 660V 3850A {660V}](https://epri-peac.com/solar-equipment/inverters/sma-america/sma-america-sc-4400-up-us-660v-3850a-660v/)
- [SMA America: SC 4200 UP-US 630V 3850A {630V}](https://epri-peac.com/solar-equipment/inverters/sma-america/sma-america-sc-4200-up-us-630v-3850a-630v/)
- [SMA America: SC 4000 UP-US 600V 3850A {600V}](https://epri-peac.com/solar-equipment/inverters/sma-america/sma-america-sc-4000-up-us-600v-3850a-600v/)
- [SMA America: SC 3060 UP-US 690V 2566A {690V}](https://epri-peac.com/solar-equipment/inverters/sma-america/sma-america-sc-3060-up-us-690v-2566a-690v/)
