Manufacturer: [**SMA America**](https://epri-peac.com/solar-equipment/brands/sma-america/) Registry: **CEC Verified Engineering Specification**

SMA America: SHP 172-US-21 {660V} outputs 172,000 W AC at 660 V, 3-phase (150.5 A continuous, 200 A OCPD), ranking #60 of 2,343 CEC inverters at 98.57% efficiency with a 968-1,200 V MPPT window and 1,200 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 172,000 W

- **AC Voltage** : 660 V, 3-phase

- **Min PV Breaker** : 200 A (3/0 AWG Cu)

- **CEC Efficiency** : 98.57%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does SMA America: SHP 172-US-21 {660V} Compare Against Peer CEC Listings?

CEC efficiency rank (#60), 968-1,200 V MPPT tracking, and panel fit for SMA America: SHP 172-US-21 {660V}. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Operating at 660 V, 3-phase, SMA America: SHP 172-US-21 {660V} converts DC array energy at 98.57% CEC weighted efficiency (top 2.7%; higher than 97.3% of peers) with a 1,200 V max DC input and 160.235 A max input current for NEC 690.7 string safety. Compare this 172,000 W grid-tied PV inverter directly with KACO new energy GmbH: KACO blueplanet 150 TL3 M1 WM OD IIQ0 {660V} (151,228 W). Commercial 660 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (660V) or NEC 705.11 supply-side tap.

## Where Does SMA America: SHP 172-US-21 {660V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting SMA America: SHP 172-US-21 {660V} at 172,000 W continuous AC output. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

## What Dataset Percentiles Define SMA America: SHP 172-US-21 {660V}?

Dataset percentiles comparing SMA America: SHP 172-US-21 {660V} against 2,343 certified grid-support inverters nationwide. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

## What Do the Dataset Ranks Show for SMA America: SHP 172-US-21 {660V}?

Engineering highlights for SMA America: SHP 172-US-21 {660V} covering efficiency, 3/0 AWG Cu feeder, and panel compatibility.

Eff #60 / 2,343

### 98.57% CEC Weighted Efficiency

+0.36 pts vs the 98.21% 660 V median; overall power rank #261 (172,000 W, top 11.1%; higher than 88.9% of peers).

NEC 705.12 Check

### 200 A Required Backfeed OCPD

125% x 150.5 A = 188.1 A -> 200 A standard OCPD using 3/0 AWG Cu (75 C).

MPPT Window

### 968 V - 1,200 V (Max 1,200 V DC)

Tracking span of 232.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

### Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 660 V, 3-phase switchgear (200A Bus / 200A Main (660V) to 1,200A Bus / 1,200A Main (660V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 172000.0W / 660 V 3-phase -> 150.5 A | Breaker >= 1.25 * 150.5 = 188.1 A -> 200 A

CEC Inverters.csv for SMA America: SHP 172-US-21 {660V}: Paco=172000.0 W, Vac=660 V, Vdcmax=1200.0 V, Eff=98.57%.

**Result:** Min 200 A breaker & 3/0 AWG Cu (75 C); 1,200A Bus / 1,200A Main (660V): PASS (120% Commercial Busbar).

## What Are the Published CEC Specifications for SMA America: SHP 172-US-21 {660V}?

California Energy Commission Solar Equipment List parameters for SMA America: SHP 172-US-21 {660V} (grid-tied PV inverter) interconnection. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Official California Energy Commission (NREL SAM) test parameters for SMA America: SHP 172-US-21 {660V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 172,000 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 660 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 1,200 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 968 V - 1,200 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 160.235 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 98.57% | Calculated AC/DC conversion ratio from CEC test protocol |
| **Inverter Topology** | Hybrid: No (Grid-Tied PV) | CEC Solar Equipment List grid-support certification |

## What Switchgear Limits Apply to SMA America: SHP 172-US-21 {660V} (660 V, 3-phase)?

Panelboard and switchgear backfeed allowances for SMA America: SHP 172-US-21 {660V} (200 A OCPD). Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Evaluates SMA America: SHP 172-US-21 {660V} (200 A required OCPD at 660 V, 3-phase) across standard distribution busbars.

| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **200A Bus / 200A Main (660V)** | 40 A | 200 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **400A Bus / 400A Main (660V)** | 80 A | 200 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **600A Bus / 600A Main (660V)** | 120 A | 200 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **800A Bus / 800A Main (660V)** | 160 A | 200 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **1,200A Bus / 1,200A Main (660V)** | 240 A | 200 A | PASS (120% Commercial Busbar) |

## Which Competing Grid-Support Inverters Compare to SMA America: SHP 172-US-21 {660V}?

Four alternative CEC inverters matched to SMA America: SHP 172-US-21 {660V} (172,000 W AC), led by KACO new energy GmbH: KACO blueplanet 150 TL3 M1 WM OD IIQ0 {660V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**KACO new energy GmbH: KACO blueplanet 150 TL3 M1 WM OD IIQ0 {660V}**](https://epri-peac.com/solar-equipment/inverters/kaco-new-energy-gmbh/kaco-new-energy-gmbh-kaco-blueplanet-150-tl3-m1-wm-od-iiq0-660v/) KACO new energy GmbH | 151,228 W | -20772 W | 660.0 V | 1300.0 V | 98.78% |
| [**KACO new energy GmbH: KACO blueplanet 150 TL3 M1 WM OD IIQX {660V}**](https://epri-peac.com/solar-equipment/inverters/kaco-new-energy-gmbh/kaco-new-energy-gmbh-kaco-blueplanet-150-tl3-m1-wm-od-iiqx-660v/) KACO new energy GmbH | 151,228 W | -20772 W | 660.0 V | 1300.0 V | 98.78% |
| [**EPC Power Corp: 50-200100 {660V}**](https://epri-peac.com/solar-equipment/inverters/epc-power-corp/epc-power-corp-50-200100-660v/) EPC Power Corp | 515,072 W | +343072 W | 660.0 V | 1500.0 V | 98.47% |
| [**INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1715TL U B660 {660V}**](https://epri-peac.com/solar-equipment/inverters/ingeteam-power-technology-sa/ingeteam-power-technology-sa-ingecon-sun-1715tl-u-b660-660v/) INGETEAM POWER TECHNOLOGY SA | 1,390,614 W | +1218614 W | 660.0 V | 1200.0 V | 97.22% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for SMA America: SHP 172-US-21 {660V}?

Check SMA America: SHP 172-US-21 {660V} (172,000 W AC, 200 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 660 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (660V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,200 V DC on SMA America: SHP 172-US-21 {660V}.

### SMA America: SHP 172-US-21 {660V} Panel & Wire Spec

Size 75 C copper conductors at 3/0 AWG Cu on a 200 A OCPD breaker (150.5 A continuous).

### Alternative Inverter Comparison

Compare efficiency (98.57%) and MPPT window (968-1,200 V) directly against KACO new energy GmbH: KACO blueplanet 150 TL3 M1 WM OD IIQ0 {660V} (151,228 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for SMA America: SHP 172-US-21 {660V} by SMA America covering breaker sizing, MPPT limits, and 660 V, 3-phase interconnection.

### What breaker and wire size does SMA America: SHP 172-US-21 {660V} require?

At 172,000 W continuous AC (660 V, 3-phase), continuous current is 150.5 A; 125% NEC 690.8/705.12 sizing requires a 200 A breaker and 3/0 AWG Cu (75 C) wire.

### What commercial switchgear or feeder sizing does SMA America: SHP 172-US-21 {660V} require?

At 172,000 W AC and 660 V, 3-phase, continuous line current is 150.5 A, requiring a 200 A OCPD and 1,200A Bus / 1,200A Main (660V) or NEC 705.11 interconnection.

### How does SMA America: SHP 172-US-21 {660V} compare to KACO new energy GmbH: KACO blueplanet 150 TL3 M1 WM OD IIQ0 {660V}?

SMA America: SHP 172-US-21 {660V} delivers 172,000 W AC at 98.57% CEC efficiency with a 1,200 V DC ceiling, while KACO new energy GmbH: KACO blueplanet 150 TL3 M1 WM OD IIQ0 {660V} outputs 151,228 W at 660 V, 3-phase.

## Related Pages

Explore SMA America hardware, KACO new energy GmbH: KACO blueplanet 150 TL3 M1 WM OD IIQ0 {660V}, utility rates, and NEC 705.12 sizing calculators alongside SMA America: SHP 172-US-21 {660V}.

[All SMA America Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/sma-america/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From SMA America

- [All SMA America Specs](https://epri-peac.com/solar-equipment/brands/sma-america/)
- [SMA America: SC 4600 UP-US 690V 3850A {690V}](https://epri-peac.com/solar-equipment/inverters/sma-america/sma-america-sc-4600-up-us-690v-3850a-690v/)
- [SMA America: SC 4400 UP-US 660V 3850A {660V}](https://epri-peac.com/solar-equipment/inverters/sma-america/sma-america-sc-4400-up-us-660v-3850a-660v/)
- [SMA America: SC 4200 UP-US 630V 3850A {630V}](https://epri-peac.com/solar-equipment/inverters/sma-america/sma-america-sc-4200-up-us-630v-3850a-630v/)
- [SMA America: SC 4000 UP-US 600V 3850A {600V}](https://epri-peac.com/solar-equipment/inverters/sma-america/sma-america-sc-4000-up-us-600v-3850a-600v/)
- [SMA America: SC 3060 UP-US 690V 2566A {690V}](https://epri-peac.com/solar-equipment/inverters/sma-america/sma-america-sc-3060-up-us-690v-2566a-690v/)