title: "SMA America: SC 4200 UP-US 630V Inverter (3,832,828W)"
url: https://epri-peac.com/solar-equipment/inverters/sma-america/sma-america-sc-4200-up-us-630v-3850a-630v/
description: "CEC specs for SMA America: SC 4200 UP-US 630V 3850A {630V}: 3,832,828W AC, 630V, 4400A OCPD, and NEC 705.12 checks. Source-verified US engineering data."
---

CEC Grid-Support Inverter

# SMA America: SC 4200 UP-US 630V 3850A {630V} — CEC Inverter Specifications

Manufacturer: [**SMA America**](https://epri-peac.com/solar-equipment/brands/sma-america/) Registry: **CEC Verified Engineering Specification**

SMA America: SC 4200 UP-US 630V 3850A {630V} outputs 3,832,828 W AC at 630 V, 3-phase (3512.6 A continuous, 4,400 A OCPD), ranking #282 of 2,343 CEC inverters at 98.13% efficiency with a 921-1,200 V MPPT window and 1,200 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 3,832,828 W

- **AC Voltage** : 630 V, 3-phase

- **Min PV Breaker** : 4,400 A (parallel Cu feeders)

- **CEC Efficiency** : 98.13%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does SMA America: SC 4200 UP-US 630V 3850A {630V} Compare Against Peer CEC Listings?

CEC efficiency rank (#282), 921-1,200 V MPPT tracking, and panel fit for SMA America: SC 4200 UP-US 630V 3850A {630V}.

Operating at 630 V, 3-phase, SMA America: SC 4200 UP-US 630V 3850A {630V} converts DC array energy at 98.13% CEC weighted efficiency (top 12.2%; higher than 87.8% of peers) with a 1,200 V max DC input and 3901.8 A max input current for NEC 690.7 string safety. Compare this 3,832,828 W hybrid battery-capable inverter directly with Power Electronics: FS4010K {630V} (4,058,537 W). Commercial 630 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (630V) or NEC 705.11 supply-side tap.

## Where Does SMA America: SC 4200 UP-US 630V 3850A {630V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting SMA America: SC 4200 UP-US 630V 3850A {630V} at 3,832,828 W continuous AC output.

## What Dataset Percentiles Define SMA America: SC 4200 UP-US 630V 3850A {630V}?

Dataset percentiles comparing SMA America: SC 4200 UP-US 630V 3850A {630V} against 2,343 certified grid-support inverters nationwide. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

## What Do the Dataset Ranks Show for SMA America: SC 4200 UP-US 630V 3850A {630V}?

Engineering highlights for SMA America: SC 4200 UP-US 630V 3850A {630V} covering efficiency, parallel Cu feeders feeder, and panel compatibility.

Eff #282 / 2,343

### 98.13% CEC Weighted Efficiency

+0.19 pts vs the 97.94% 630 V median; overall power rank #15 (3,832,828 W, top 0.6%; higher than 99.4% of peers).

NEC 705.12 Check

### 4,400 A Required Backfeed OCPD

125% x 3512.6 A = 4390.8 A -> 4,400 A standard OCPD using parallel Cu feeders (75 C).

MPPT Window

### 921 V - 1,200 V (Max 1,200 V DC)

Tracking span of 279.0 V; active in CEC directory (hybrid battery-capable inverter).

Commercial / 3-Phase Fit

### Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 630 V, 3-phase switchgear (200A Bus / 200A Main (630V) to 1,200A Bus / 1,200A Main (630V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 3832828.0W / 630 V 3-phase -> 3512.6 A | Breaker >= 1.25 * 3512.6 = 4390.8 A -> 4,400 A

CEC Inverters.csv for SMA America: SC 4200 UP-US 630V 3850A {630V}: Paco=3832828.0 W, Vac=630 V, Vdcmax=1200.0 V, Eff=98.13%.

**Result:** Min 4,400 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (630V): Supply-Side Tap (705.11) / Dedicated Switchboard.

## What Are the Published CEC Specifications for SMA America: SC 4200 UP-US 630V 3850A {630V}?

California Energy Commission Solar Equipment List parameters for SMA America: SC 4200 UP-US 630V 3850A {630V} (hybrid battery-capable inverter) interconnection.

Official California Energy Commission (NREL SAM) test parameters for SMA America: SC 4200 UP-US 630V 3850A {630V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 3,832,828 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 630 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 1,200 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 921 V - 1,200 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 3901.8 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 98.13% | Calculated AC/DC conversion ratio from CEC test protocol |
| **Inverter Topology** | Hybrid: Yes (Battery Capable) | CEC Solar Equipment List grid-support certification |

## What Switchgear Limits Apply to SMA America: SC 4200 UP-US 630V 3850A {630V} (630 V, 3-phase)?

Panelboard and switchgear backfeed allowances for SMA America: SC 4200 UP-US 630V 3850A {630V} (4,400 A OCPD). Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Evaluates SMA America: SC 4200 UP-US 630V 3850A {630V} (4400 A required OCPD at 630 V, 3-phase) across standard distribution busbars.

| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **200A Bus / 200A Main (630V)** | 40 A | 4,400 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **400A Bus / 400A Main (630V)** | 80 A | 4,400 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **600A Bus / 600A Main (630V)** | 120 A | 4,400 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **800A Bus / 800A Main (630V)** | 160 A | 4,400 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **1,200A Bus / 1,200A Main (630V)** | 240 A | 4,400 A | Supply-Side Tap (705.11) / Dedicated Switchboard |

## Which CEC PV Module Strings Pair With SMA America: SC 4200 UP-US 630V 3850A {630V}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for SMA America: SC 4200 UP-US 630V 3850A {630V}.

Sampled CEC PV modules aligned within 921.0-1200.0 V MPPT and 1200.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 28 panels (fixed) | 12.32 kW |

## Which Competing Grid-Support Inverters Compare to SMA America: SC 4200 UP-US 630V 3850A {630V}?

Four alternative CEC inverters matched to SMA America: SC 4200 UP-US 630V 3850A {630V} (3,832,828 W AC), led by Power Electronics: FS4010K {630V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Power Electronics: FS4010K {630V}**](https://epri-peac.com/solar-equipment/inverters/power-electronics/power-electronics-fs4010k-630v/) Power Electronics | 4,058,537 W | +225709 W | 630.0 V | 1200.0 V | 97.83% |
| [**Sungrow Power Supply Co Ltd: SG3600UD {630V}**](https://epri-peac.com/solar-equipment/inverters/sungrow-power-supply-co-ltd/sungrow-power-supply-co-ltd-sg3600ud-630v/) Sungrow Power Supply Co Ltd | 3,606,980 W | -225848 W | 630.0 V | 1300.0 V | 97.27% |
| [**Gamesa Electric: PV4000 {630V}**](https://epri-peac.com/solar-equipment/inverters/gamesa-electric/gamesa-electric-pv4000-630v/) Gamesa Electric | 3,597,332 W | -235496 W | 630.0 V | 1300.0 V | 97.62% |
| [**Gamesa Electric: PV4300 {630V}**](https://epri-peac.com/solar-equipment/inverters/gamesa-electric/gamesa-electric-pv4300-630v/) Gamesa Electric | 4,260,428 W | +427600 W | 630.0 V | 1300.0 V | 97.6% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for SMA America: SC 4200 UP-US 630V 3850A {630V}?

Check SMA America: SC 4200 UP-US 630V 3850A {630V} (3,832,828 W AC, 4,400 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 630 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (630V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,200 V DC on SMA America: SC 4200 UP-US 630V 3850A {630V}.

### SMA America: SC 4200 UP-US 630V 3850A {630V} Panel & Wire Spec

Size 75 C copper conductors at parallel Cu feeders on a 4,400 A OCPD breaker (3512.6 A continuous).

### Alternative Inverter Comparison

Compare efficiency (98.13%) and MPPT window (921-1,200 V) directly against Power Electronics: FS4010K {630V} (4,058,537 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for SMA America: SC 4200 UP-US 630V 3850A {630V} by SMA America covering breaker sizing, MPPT limits, and 630 V, 3-phase interconnection.

### What breaker and wire size does SMA America: SC 4200 UP-US 630V 3850A {630V} require?

At 3,832,828 W continuous AC (630 V, 3-phase), continuous current is 3512.6 A; 125% NEC 690.8/705.12 sizing requires a 4,400 A breaker and parallel Cu feeders (75 C) wire.

### What commercial switchgear or feeder sizing does SMA America: SC 4200 UP-US 630V 3850A {630V} require?

At 3,832,828 W AC and 630 V, 3-phase, continuous line current is 3512.6 A, requiring a 4,400 A OCPD and 1,200A Bus / 1,200A Main (630V) or NEC 705.11 interconnection.

### How does SMA America: SC 4200 UP-US 630V 3850A {630V} compare to Power Electronics: FS4010K {630V}?

SMA America: SC 4200 UP-US 630V 3850A {630V} delivers 3,832,828 W AC at 98.13% CEC efficiency with a 1,200 V DC ceiling, while Power Electronics: FS4010K {630V} outputs 4,058,537 W at 630 V, 3-phase.

## Related Pages

Explore SMA America hardware, Power Electronics: FS4010K {630V}, utility rates, and NEC 705.12 sizing calculators alongside SMA America: SC 4200 UP-US 630V 3850A {630V}.

[All SMA America Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/sma-america/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From SMA America

- [All SMA America Specs](https://epri-peac.com/solar-equipment/brands/sma-america/)
- [SMA America: SC 4600 UP-US 690V 3850A {690V}](https://epri-peac.com/solar-equipment/inverters/sma-america/sma-america-sc-4600-up-us-690v-3850a-690v/)
- [SMA America: SC 4400 UP-US 660V 3850A {660V}](https://epri-peac.com/solar-equipment/inverters/sma-america/sma-america-sc-4400-up-us-660v-3850a-660v/)
- [SMA America: SC 4000 UP-US 600V 3850A {600V}](https://epri-peac.com/solar-equipment/inverters/sma-america/sma-america-sc-4000-up-us-600v-3850a-600v/)
- [SMA America: SC 3060 UP-US 690V 2566A {690V}](https://epri-peac.com/solar-equipment/inverters/sma-america/sma-america-sc-3060-up-us-690v-2566a-690v/)
- [SMA America: SC 2930 UP-US 660V 2566A {660V}](https://epri-peac.com/solar-equipment/inverters/sma-america/sma-america-sc-2930-up-us-660v-2566a-660v/)