title: "SMA America: SC-2200-US {385V} Inverter (2,079,000W)"
url: https://epri-peac.com/solar-equipment/inverters/sma-america/sma-america-sc-2200-us-385v/
description: "CEC specs for SMA America: SC-2200-US {385V}: 2,079,000W AC, 385V, 3900A OCPD, and NEC 705.12 checks. Verified US government and CEC engineering data."
---

CEC Grid-Support Inverter

# SMA America: SC-2200-US {385V} — CEC Inverter Specifications

Manufacturer: [**SMA America**](https://epri-peac.com/solar-equipment/brands/sma-america/) Registry: **CEC Verified Engineering Specification**

SMA America: SC-2200-US {385V} outputs 2,079,000 W AC at 385 V, 3-phase (3117.8 A continuous, 3,900 A OCPD), ranking #1,423 of 2,343 CEC inverters at 96.58% efficiency with a 570-950 V MPPT window and 950 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 2,079,000 W

- **AC Voltage** : 385 V, 3-phase

- **Min PV Breaker** : 3,900 A (parallel Cu feeders)

- **CEC Efficiency** : 96.58%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does SMA America: SC-2200-US {385V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 385 V, 3-phase grid-support overview for SMA America: SC-2200-US {385V}. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Rated at 2,079,000 W AC (3117.8 A continuous), SMA America: SC-2200-US {385V} ranks #1,423 of 2,343 CEC units at 96.58% efficiency (-0.26 pts vs the 96.84% 385 V median). Minimum 75 C copper conductor sizing for its 3,900 A circuit is parallel Cu feeders per NEC Table 310.16. Cold-weather string Voc must remain under 950 V DC at record local winter lows.

## Where Does SMA America: SC-2200-US {385V} Fall Across Listed CEC Models?

Marks SMA America: SC-2200-US {385V} (2,079,000 W AC) across the California Energy Commission inverter AC capacity distribution. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

## What Dataset Percentiles Define SMA America: SC-2200-US {385V}?

Benchmarks SMA America: SC-2200-US {385V} continuous AC output, 96.58% CEC weighted efficiency, and 3,900 A OCPD breaker demand.

## What Do the Dataset Ranks Show for SMA America: SC-2200-US {385V}?

Four key NEC 705.12 and California Energy Commission metrics defining SMA America: SC-2200-US {385V} by SMA America. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Eff #1,423 / 2,343

### 96.58% CEC Weighted Efficiency

-0.26 pts vs the 96.84% 385 V median; overall power rank #98 (2,079,000 W, top 4.2%; higher than 95.8% of peers).

NEC 705.12 Check

### 3,900 A Required Backfeed OCPD

125% x 3117.8 A = 3897.2 A -> 3,900 A standard OCPD using parallel Cu feeders (75 C).

MPPT Window

### 570 V - 950 V (Max 950 V DC)

Tracking span of 380.0 V; listed since 2019-02-15 (grid-tied PV inverter).

Commercial / 3-Phase Fit

### Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 385 V, 3-phase switchgear (200A Bus / 200A Main (385V) to 1,200A Bus / 1,200A Main (385V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 2079000.0W / 385 V 3-phase -> 3117.8 A | Breaker >= 1.25 * 3117.8 = 3897.2 A -> 3,900 A

CEC Inverters.csv for SMA America: SC-2200-US {385V}: Paco=2079000.0 W, Vac=385 V, Vdcmax=950.0 V, Eff=96.58%.

**Result:** Min 3,900 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (385V): Supply-Side Tap (705.11) / Dedicated Switchboard.

## What Are the Published CEC Specifications for SMA America: SC-2200-US {385V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for SMA America: SC-2200-US {385V}. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Official California Energy Commission (NREL SAM) test parameters for SMA America: SC-2200-US {385V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 2,079,000 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 385 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 950 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 570 V - 950 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 3237.15 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 96.58% | Calculated AC/DC conversion ratio from CEC test protocol |
| **CEC Listing Date & Hybrid** | 2019-02-15 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |

## What Switchgear Limits Apply to SMA America: SC-2200-US {385V} (385 V, 3-phase)?

Evaluates SMA America: SC-2200-US {385V} (3,900 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates SMA America: SC-2200-US {385V} (3900 A required OCPD at 385 V, 3-phase) across standard distribution busbars.

| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **200A Bus / 200A Main (385V)** | 40 A | 3,900 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **400A Bus / 400A Main (385V)** | 80 A | 3,900 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **600A Bus / 600A Main (385V)** | 120 A | 3,900 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **800A Bus / 800A Main (385V)** | 160 A | 3,900 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **1,200A Bus / 1,200A Main (385V)** | 240 A | 3,900 A | Supply-Side Tap (705.11) / Dedicated Switchboard |

## Which CEC PV Module Strings Pair With SMA America: SC-2200-US {385V}?

Sample PV string lengths aligned within 570-950 V MPPT and 950 V DC max at -10 C. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sampled CEC PV modules aligned within 570.0-950.0 V MPPT and 950.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 14 to 16 panels | 9.44 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 18 to 22 panels | 9.68 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 17 to 21 panels | 8.93 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 20 to 23 panels | 4.6 kW |

## Which Competing Grid-Support Inverters Compare to SMA America: SC-2200-US {385V}?

Competing CEC grid-support inverters near 2,079,000 W AC and 385 V, 3-phase, led by Power Electronics: FS2250CU15O3 {600V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Power Electronics: FS2250CU15O3 {600V}**](https://epri-peac.com/solar-equipment/inverters/power-electronics/power-electronics-fs2250cu15o3-600v/) Power Electronics | 2,420,370 W | +341370 W | 600.0 V | 1200.0 V | 97.82% |
| [**SINENG ELECTRIC CO LTD: EH-1725-HA-UD-US {690V}**](https://epri-peac.com/solar-equipment/inverters/sineng-electric-co-ltd/sineng-electric-co-ltd-eh-1725-ha-ud-us-690v/) SINENG ELECTRIC CO LTD | 1,726,700 W | -352300 W | 690.0 V | 1500.0 V | 98.32% |
| [**INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C480 {480V}**](https://epri-peac.com/solar-equipment/inverters/ingeteam-power-technology-sa/ingeteam-power-technology-sa-ingecon-sun-storage-3660tl-u-c480-480v/) INGETEAM POWER TECHNOLOGY SA | 2,467,620 W | +388620 W | 480.0 V | 1300.0 V | 96.63% |
| [**Schneider Electric USA Inc: CS1666-3-NA {575V}**](https://epri-peac.com/solar-equipment/inverters/schneider-electric-usa-inc/schneider-electric-usa-inc-cs1666-3-na-575v/) Schneider Electric USA Inc | 1,666,000 W | -413000 W | 575.0 V | 1200.0 V | 97.54% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for SMA America: SC-2200-US {385V}?

Check SMA America: SC-2200-US {385V} (2,079,000 W AC, 3,900 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 385 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (385V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 950 V DC on SMA America: SC-2200-US {385V}.

### SMA America: SC-2200-US {385V} Panel & Wire Spec

Size 75 C copper conductors at parallel Cu feeders on a 3,900 A OCPD breaker (3117.8 A continuous).

### Alternative Inverter Comparison

Compare efficiency (96.58%) and MPPT window (570-950 V) directly against Power Electronics: FS2250CU15O3 {600V} (2,420,370 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for SMA America: SC-2200-US {385V} by SMA America covering breaker sizing, MPPT limits, and 385 V, 3-phase interconnection.

### What breaker and wire size does SMA America: SC-2200-US {385V} require?

At 2,079,000 W continuous AC (385 V, 3-phase), continuous current is 3117.8 A; 125% NEC 690.8/705.12 sizing requires a 3,900 A breaker and parallel Cu feeders (75 C) wire.

### What commercial switchgear or feeder sizing does SMA America: SC-2200-US {385V} require?

At 2,079,000 W AC and 385 V, 3-phase, continuous line current is 3117.8 A, requiring a 3,900 A OCPD and 1,200A Bus / 1,200A Main (385V) or NEC 705.11 interconnection.

### How does SMA America: SC-2200-US {385V} compare to Power Electronics: FS2250CU15O3 {600V}?

SMA America: SC-2200-US {385V} delivers 2,079,000 W AC at 96.58% CEC efficiency with a 950 V DC ceiling, while Power Electronics: FS2250CU15O3 {600V} outputs 2,420,370 W at 385 V, 3-phase.

## Related Pages

Explore SMA America hardware, Power Electronics: FS2250CU15O3 {600V}, utility rates, and NEC 705.12 sizing calculators alongside SMA America: SC-2200-US {385V}.

[All SMA America Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/sma-america/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From SMA America

- [All SMA America Specs](https://epri-peac.com/solar-equipment/brands/sma-america/)
- [SMA America: SC 4600 UP-US 690V 3850A {690V}](https://epri-peac.com/solar-equipment/inverters/sma-america/sma-america-sc-4600-up-us-690v-3850a-690v/)
- [SMA America: SC 4400 UP-US 660V 3850A {660V}](https://epri-peac.com/solar-equipment/inverters/sma-america/sma-america-sc-4400-up-us-660v-3850a-660v/)
- [SMA America: SC 4200 UP-US 630V 3850A {630V}](https://epri-peac.com/solar-equipment/inverters/sma-america/sma-america-sc-4200-up-us-630v-3850a-630v/)
- [SMA America: SC 4000 UP-US 600V 3850A {600V}](https://epri-peac.com/solar-equipment/inverters/sma-america/sma-america-sc-4000-up-us-600v-3850a-600v/)
- [SMA America: SC 3060 UP-US 690V 2566A {690V}](https://epri-peac.com/solar-equipment/inverters/sma-america/sma-america-sc-3060-up-us-690v-2566a-690v/)