title: "SMA America: SBSE58-US-50 {240V} Inverter (5,776W)"
url: https://epri-peac.com/solar-equipment/inverters/sma-america/sma-america-sbse58-us-50-240v/
description: "CEC specs for SMA America: SBSE58-US-50 {240V}: 5,776W AC, 240V, 35A OCPD, and NEC 705.12 checks. Verified US government and CEC engineering data."
---

CEC Grid-Support Inverter

# SMA America: SBSE58-US-50 {240V} — CEC Inverter Specifications

Manufacturer: [**SMA America**](https://epri-peac.com/solar-equipment/brands/sma-america/) Registry: **CEC Verified Engineering Specification**

SMA America: SBSE58-US-50 {240V} outputs 5,776 W AC at 240 V (24.1 A continuous, 35 A OCPD), ranking #595 of 2,343 CEC inverters at 97.41% efficiency with a 136-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 5,776 W

- **AC Voltage** : 240 V

- **Min PV Breaker** : 35 A (8 AWG Cu)

- **CEC Efficiency** : 97.41%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does SMA America: SBSE58-US-50 {240V} Compare Against Peer CEC Listings?

CEC efficiency rank (#595), 136-480 V MPPT tracking, and panel fit for SMA America: SBSE58-US-50 {240V}. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

SMA America: SBSE58-US-50 {240V} from SMA America outputs 24.1 A continuous AC at 240 V (5,776 W AC, rank #1,435). Paired with 8 AWG Cu conductors and a 35 A OCPD, its 97.41% CEC efficiency compares closely with Delta Electronics: E6-TL-US {240V} (5,760 W). Keep NEC 690.7 winter string Voc below 480 V DC.

## Where Does SMA America: SBSE58-US-50 {240V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting SMA America: SBSE58-US-50 {240V} at 5,776 W continuous AC output. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

## What Dataset Percentiles Define SMA America: SBSE58-US-50 {240V}?

Dataset percentiles comparing SMA America: SBSE58-US-50 {240V} against 2,343 certified grid-support inverters nationwide. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

## What Do the Dataset Ranks Show for SMA America: SBSE58-US-50 {240V}?

Engineering highlights for SMA America: SBSE58-US-50 {240V} covering efficiency, 8 AWG Cu feeder, and panel compatibility. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Eff #595 / 2,343

### 97.41% CEC Weighted Efficiency

+0.73 pts vs the 96.68% 240 V median; overall power rank #1,435 (5,776 W, below CEC median; higher than 38.8% of peers).

NEC 705.12 Check

### 35 A Required Backfeed OCPD

125% x 24.1 A = 30.1 A -> 35 A standard OCPD using 8 AWG Cu (75 C).

MPPT Window

### 136 V - 480 V (Max 480 V DC)

Tracking span of 344.0 V; active in CEC directory (hybrid battery-capable inverter).

Panel Fit (240V)

### PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 5775.9W / 240 V -> 24.1 A | Breaker >= 1.25 * 24.1 = 30.1 A -> 35 A

CEC Inverters.csv for SMA America: SBSE58-US-50 {240V}: Paco=5775.9 W, Vac=240 V, Vdcmax=480.0 V, Eff=97.41%.

**Result:** Min 35 A breaker & 8 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

## What Are the Published CEC Specifications for SMA America: SBSE58-US-50 {240V}?

California Energy Commission Solar Equipment List parameters for SMA America: SBSE58-US-50 {240V} (hybrid battery-capable inverter) interconnection. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Official California Energy Commission (NREL SAM) test parameters for SMA America: SBSE58-US-50 {240V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 5,776 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 480 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 136 V - 480 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 15.2429 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 97.41% | Calculated AC/DC conversion ratio from CEC test protocol |
| **Inverter Topology** | Hybrid: Yes (Battery Capable) | CEC Solar Equipment List grid-support certification |

## Can a Residential Panel Meet 120% Busbar Limits for SMA America: SBSE58-US-50 {240V}?

Panelboard and switchgear backfeed allowances for SMA America: SBSE58-US-50 {240V} (35 A OCPD). All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Evaluates SMA America: SBSE58-US-50 {240V} (35 A required OCPD at 240 V) across standard distribution busbars.

| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **100A Bus / 100A Main** | 20 A | 35 A | Needs Derate / Tap 705.11 |
| **150A Bus / 150A Main** | 30 A | 35 A | Needs Derate / Tap 705.11 |
| **200A Bus / 200A Main** | 40 A | 35 A | PASS (120% Rule) |
| **200A Bus / 175A Main** | 65 A | 35 A | PASS (120% Rule) |
| **225A Bus / 200A Main** | 70 A | 35 A | PASS (120% Rule) |

## Which CEC PV Module Strings Pair With SMA America: SBSE58-US-50 {240V}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for SMA America: SBSE58-US-50 {240V}. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Sampled CEC PV modules aligned within 136.0-480.0 V MPPT and 480.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 4 to 8 panels | 4.72 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 5 to 11 panels | 4.84 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 4 to 10 panels | 4.25 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 5 to 11 panels | 2.2 kW |

## Which Competing Grid-Support Inverters Compare to SMA America: SBSE58-US-50 {240V}?

Four alternative CEC inverters matched to SMA America: SBSE58-US-50 {240V} (5,776 W AC), led by Delta Electronics: E6-TL-US {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Delta Electronics: E6-TL-US {240V}**](https://epri-peac.com/solar-equipment/inverters/delta-electronics/delta-electronics-e6-tl-us-240v/) Delta Electronics | 5,760 W | -16 W | 240.0 V | 480.0 V | 97.35% |
| [**Delta Electronics: M6-TL-US {240V}**](https://epri-peac.com/solar-equipment/inverters/delta-electronics/delta-electronics-m6-tl-us-240v/) Delta Electronics | 5,760 W | -16 W | 240.0 V | 480.0 V | 97.37% |
| [**Delta Electronics: E6_BDI {240V}**](https://epri-peac.com/solar-equipment/inverters/delta-electronics/delta-electronics-e6-bdi-240v/) Delta Electronics | 5,823 W | +47 W | 240.0 V | 480.0 V | 97.63% |
| [**Base Power Inc: MIN 6000TL-XH-US {240V}**](https://epri-peac.com/solar-equipment/inverters/base-power-inc/base-power-inc-min-6000tl-xh-us-240v/) Base Power Inc | 5,918 W | +142 W | 240.0 V | 480.0 V | 97.26% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for SMA America: SBSE58-US-50 {240V}?

Check SMA America: SBSE58-US-50 {240V} (5,776 W AC, 35 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Requires a 35 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on SMA America: SBSE58-US-50 {240V}.

### SMA America: SBSE58-US-50 {240V} Panel & Wire Spec

Size 75 C copper conductors at 8 AWG Cu on a 35 A OCPD breaker (24.1 A continuous).

### Alternative Inverter Comparison

Compare efficiency (97.41%) and MPPT window (136-480 V) directly against Delta Electronics: E6-TL-US {240V} (5,760 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for SMA America: SBSE58-US-50 {240V} by SMA America covering breaker sizing, MPPT limits, and 240 V interconnection.

### What breaker and wire size does SMA America: SBSE58-US-50 {240V} require?

At 5,776 W continuous AC (240 V), continuous current is 24.1 A; 125% NEC 690.8/705.12 sizing requires a 35 A breaker and 8 AWG Cu (75 C) wire.

### Does SMA America: SBSE58-US-50 {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 35 A at 240 V means PASS (120% Rule).

### How does SMA America: SBSE58-US-50 {240V} compare to Delta Electronics: E6-TL-US {240V}?

SMA America: SBSE58-US-50 {240V} delivers 5,776 W AC at 97.41% CEC efficiency with a 480 V DC ceiling, while Delta Electronics: E6-TL-US {240V} outputs 5,760 W at 240 V.

## Related Pages

Explore SMA America hardware, Delta Electronics: E6-TL-US {240V}, utility rates, and NEC 705.12 sizing calculators alongside SMA America: SBSE58-US-50 {240V}.

[All SMA America Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/sma-america/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From SMA America

- [All SMA America Specs](https://epri-peac.com/solar-equipment/brands/sma-america/)
- [SMA America: SC 4600 UP-US 690V 3850A {690V}](https://epri-peac.com/solar-equipment/inverters/sma-america/sma-america-sc-4600-up-us-690v-3850a-690v/)
- [SMA America: SC 4400 UP-US 660V 3850A {660V}](https://epri-peac.com/solar-equipment/inverters/sma-america/sma-america-sc-4400-up-us-660v-3850a-660v/)
- [SMA America: SC 4200 UP-US 630V 3850A {630V}](https://epri-peac.com/solar-equipment/inverters/sma-america/sma-america-sc-4200-up-us-630v-3850a-630v/)
- [SMA America: SC 4000 UP-US 600V 3850A {600V}](https://epri-peac.com/solar-equipment/inverters/sma-america/sma-america-sc-4000-up-us-600v-3850a-600v/)
- [SMA America: SC 3060 UP-US 690V 2566A {690V}](https://epri-peac.com/solar-equipment/inverters/sma-america/sma-america-sc-3060-up-us-690v-2566a-690v/)