Manufacturer: [**SMA America**](https://epri-peac.com/solar-equipment/brands/sma-america/) Registry: **CEC Verified Engineering Specification**

SMA America: SBSE115-US-50 {240V} outputs 11,483 W AC at 240 V (47.8 A continuous, 60 A OCPD), ranking #721 of 2,343 CEC inverters at 97.25% efficiency with a 200-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 11,483 W

- **AC Voltage** : 240 V

- **Min PV Breaker** : 60 A (6 AWG Cu)

- **CEC Efficiency** : 97.25%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does SMA America: SBSE115-US-50 {240V} Compare Against Peer CEC Listings?

How SMA America SMA America: SBSE115-US-50 {240V} compares on 97.25% efficiency, MPPT span, and 120% busbar interconnection. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

SMA America certifies SMA America: SBSE115-US-50 {240V} (hybrid battery-capable inverter, active in CEC directory) at 11,483 W AC (5,707 W above the 5,776 W 240 V median). Its 480 V DC ceiling pairs with an MPPT window of 200-480 V (span 280.0 V). Under NEC 690.8/705.12, 125% sizing demands 6 AWG Cu conductors on a 60 A OCPD.

## Where Does SMA America: SBSE115-US-50 {240V} Fall Across Listed CEC Models?

Position of SMA America: SBSE115-US-50 {240V} (11,483 W AC) relative to the 7,680 W CEC median inverter. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

## What Dataset Percentiles Define SMA America: SBSE115-US-50 {240V}?

Percentile placement of SMA America: SBSE115-US-50 {240V} across AC power class, conversion efficiency, and backfeed breaker size. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

## What Do the Dataset Ranks Show for SMA America: SBSE115-US-50 {240V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for SMA America: SBSE115-US-50 {240V}. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Eff #721 / 2,343

### 97.25% CEC Weighted Efficiency

+0.57 pts vs the 96.68% 240 V median; overall power rank #769 (11,483 W, top 32.8%; higher than 67.2% of peers).

NEC 705.12 Check

### 60 A Required Backfeed OCPD

125% x 47.8 A = 59.8 A -> 60 A standard OCPD using 6 AWG Cu (75 C).

MPPT Window

### 200 V - 480 V (Max 480 V DC)

Tracking span of 280.0 V; active in CEC directory (hybrid battery-capable inverter).

Panel Fit (240V)

### Needs Derate / Tap 705.11

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 11483.0W / 240 V -> 47.8 A | Breaker >= 1.25 * 47.8 = 59.8 A -> 60 A

CEC Inverters.csv for SMA America: SBSE115-US-50 {240V}: Paco=11483.0 W, Vac=240 V, Vdcmax=480.0 V, Eff=97.25%.

**Result:** Min 60 A breaker & 6 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.

## What Are the Published CEC Specifications for SMA America: SBSE115-US-50 {240V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for SMA America: SBSE115-US-50 {240V}. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Official California Energy Commission (NREL SAM) test parameters for SMA America: SBSE115-US-50 {240V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 11,483 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 480 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 200 V - 480 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 29.1538 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 97.25% | Calculated AC/DC conversion ratio from CEC test protocol |
| **Inverter Topology** | Hybrid: Yes (Battery Capable) | CEC Solar Equipment List grid-support certification |

## Can a Residential Panel Meet 120% Busbar Limits for SMA America: SBSE115-US-50 {240V}?

Check whether SMA America: SBSE115-US-50 {240V} (60 A breaker) fits without main breaker derate or supply-side taps. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Evaluates SMA America: SBSE115-US-50 {240V} (60 A required OCPD at 240 V) across standard distribution busbars.

| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **100A Bus / 100A Main** | 20 A | 60 A | Needs Derate / Tap 705.11 |
| **150A Bus / 150A Main** | 30 A | 60 A | Needs Derate / Tap 705.11 |
| **200A Bus / 200A Main** | 40 A | 60 A | Needs Derate / Tap 705.11 |
| **200A Bus / 175A Main** | 65 A | 60 A | PASS (120% Rule) |
| **225A Bus / 200A Main** | 70 A | 60 A | PASS (120% Rule) |

## Which CEC PV Module Strings Pair With SMA America: SBSE115-US-50 {240V}?

Verified cold-weather (-10 C) series module counts matched to SMA America: SBSE115-US-50 {240V}'s 480 V DC ceiling.

Sampled CEC PV modules aligned within 200.0-480.0 V MPPT and 480.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 5 to 8 panels | 4.72 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 6 to 11 panels | 4.84 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 6 to 10 panels | 4.25 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 7 to 11 panels | 2.2 kW |

## Which Competing Grid-Support Inverters Compare to SMA America: SBSE115-US-50 {240V}?

Alternative CEC inverters comparable to SMA America: SBSE115-US-50 {240V}, including Dyness Digital Energy Technology Co LTD: TX114K-HM {240V} (11,498 W) at 240 V.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Dyness Digital Energy Technology Co LTD: TX114K-HM {240V}**](https://epri-peac.com/solar-equipment/inverters/dyness-digital-energy-technology-co-ltd/dyness-digital-energy-technology-co-ltd-tx114k-hm-240v/) Dyness Digital Energy Technology Co LTD | 11,498 W | +15 W | 240.0 V | 500.0 V | 96.41% |
| [**Dyness Digital Energy Technology Co LTD: TX114K-AM {240V}**](https://epri-peac.com/solar-equipment/inverters/dyness-digital-energy-technology-co-ltd/dyness-digital-energy-technology-co-ltd-tx114k-am-240v/) Dyness Digital Energy Technology Co LTD | 11,519 W | +36 W | 240.0 V | 490.0 V | 96.21% |
| [**Base Power Inc: MIN 11400TL-XH-US {240V}**](https://epri-peac.com/solar-equipment/inverters/base-power-inc/base-power-inc-min-11400tl-xh-us-240v/) Base Power Inc | 11,520 W | +37 W | 240.0 V | 480.0 V | 97.76% |
| [**Altenergy Power System Inc: ELS-114 {240V}**](https://epri-peac.com/solar-equipment/inverters/altenergy-power-system-inc/altenergy-power-system-inc-els-114-240v/) Altenergy Power System Inc | 11,415 W | -68 W | 240.0 V | 60.0 V | 93.08% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for SMA America: SBSE115-US-50 {240V}?

Check SMA America: SBSE115-US-50 {240V} (11,483 W AC, 60 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Its 60 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on SMA America: SBSE115-US-50 {240V}.

### SMA America: SBSE115-US-50 {240V} Panel & Wire Spec

Size 75 C copper conductors at 6 AWG Cu on a 60 A OCPD breaker (47.8 A continuous).

### Alternative Inverter Comparison

Compare efficiency (97.25%) and MPPT window (200-480 V) directly against Dyness Digital Energy Technology Co LTD: TX114K-HM {240V} (11,498 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for SMA America: SBSE115-US-50 {240V} by SMA America covering breaker sizing, MPPT limits, and 240 V interconnection.

### What breaker and wire size does SMA America: SBSE115-US-50 {240V} require?

At 11,483 W continuous AC (240 V), continuous current is 47.8 A; 125% NEC 690.8/705.12 sizing requires a 60 A breaker and 6 AWG Cu (75 C) wire.

### Does SMA America: SBSE115-US-50 {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 60 A at 240 V means Needs Derate / Tap 705.11.

### How does SMA America: SBSE115-US-50 {240V} compare to Dyness Digital Energy Technology Co LTD: TX114K-HM {240V}?

SMA America: SBSE115-US-50 {240V} delivers 11,483 W AC at 97.25% CEC efficiency with a 480 V DC ceiling, while Dyness Digital Energy Technology Co LTD: TX114K-HM {240V} outputs 11,498 W at 240 V.

## Related Pages

Explore SMA America hardware, Dyness Digital Energy Technology Co LTD: TX114K-HM {240V}, utility rates, and NEC 705.12 sizing calculators alongside SMA America: SBSE115-US-50 {240V}.

[All SMA America Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/sma-america/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From SMA America

- [All SMA America Specs](https://epri-peac.com/solar-equipment/brands/sma-america/)
- [SMA America: SC 4600 UP-US 690V 3850A {690V}](https://epri-peac.com/solar-equipment/inverters/sma-america/sma-america-sc-4600-up-us-690v-3850a-690v/)
- [SMA America: SC 4400 UP-US 660V 3850A {660V}](https://epri-peac.com/solar-equipment/inverters/sma-america/sma-america-sc-4400-up-us-660v-3850a-660v/)
- [SMA America: SC 4200 UP-US 630V 3850A {630V}](https://epri-peac.com/solar-equipment/inverters/sma-america/sma-america-sc-4200-up-us-630v-3850a-630v/)
- [SMA America: SC 4000 UP-US 600V 3850A {600V}](https://epri-peac.com/solar-equipment/inverters/sma-america/sma-america-sc-4000-up-us-600v-3850a-600v/)
- [SMA America: SC 3060 UP-US 690V 2566A {690V}](https://epri-peac.com/solar-equipment/inverters/sma-america/sma-america-sc-3060-up-us-690v-2566a-690v/)