CEC Grid-Support Inverter

# Shenzhen Senergy Technology Co Ltd: SE 8KHB-180-T2/UL {208V} — CEC Inverter Specifications

Manufacturer: [**Shenzhen Senergy Technology Co Ltd**](https://epri-peac.com/solar-equipment/brands/shenzhen-senergy-technology-co-ltd/) Registry: **CEC Verified Engineering Specification**

Shenzhen Senergy Technology Co Ltd: SE 8KHB-180-T2/UL {208V} outputs 8,060 W AC at 208 V, commercial single-phase (38.8 A continuous, 50 A OCPD), ranking #1,627 of 2,343 CEC inverters at 96.45% efficiency with a 200-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 8,060 W

- **AC Voltage** : 208 V, commercial single-phase

- **Min PV Breaker** : 50 A (8 AWG Cu)

- **CEC Efficiency** : 96.45%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Shenzhen Senergy Technology Co Ltd: SE 8KHB-180-T2/UL {208V} Compare Against Peer CEC Listings?

How Shenzhen Senergy Technology Co Ltd Shenzhen Senergy Technology Co Ltd: SE 8KHB-180-T2/UL {208V} compares on 96.45% efficiency, MPPT span, and 120% busbar interconnection.

Shenzhen Senergy Technology Co Ltd certifies Shenzhen Senergy Technology Co Ltd: SE 8KHB-180-T2/UL {208V} (hybrid battery-capable inverter, listed since 2025-04-01) at 8,060 W AC (3,060 W above the 5,000 W 208 V median). Its 480 V DC ceiling pairs with an MPPT window of 200-480 V (span 280.0 V). Under NEC 690.8/705.12, 125% sizing demands 8 AWG Cu conductors on a 50 A OCPD.

## Where Does Shenzhen Senergy Technology Co Ltd: SE 8KHB-180-T2/UL {208V} Fall Across Listed CEC Models?

Position of Shenzhen Senergy Technology Co Ltd: SE 8KHB-180-T2/UL {208V} (8,060 W AC) relative to the 7,680 W CEC median inverter.

## What Dataset Percentiles Define Shenzhen Senergy Technology Co Ltd: SE 8KHB-180-T2/UL {208V}?

Percentile placement of Shenzhen Senergy Technology Co Ltd: SE 8KHB-180-T2/UL {208V} across AC power class, conversion efficiency, and backfeed breaker size.

## What Do the Dataset Ranks Show for Shenzhen Senergy Technology Co Ltd: SE 8KHB-180-T2/UL {208V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for Shenzhen Senergy Technology Co Ltd: SE 8KHB-180-T2/UL {208V}.

Eff #1,627 / 2,343

### 96.45% CEC Weighted Efficiency

+0.04 pts vs the 96.41% 208 V median; overall power rank #1,107 (8,060 W, top 47.4%; higher than 52.6% of peers).

NEC 705.12 Check

### 50 A Required Backfeed OCPD

125% x 38.8 A = 48.5 A -> 50 A standard OCPD using 8 AWG Cu (75 C).

MPPT Window

### 200 V - 480 V (Max 480 V DC)

Tracking span of 280.0 V; listed since 2025-04-01 (hybrid battery-capable inverter).

Commercial / 3-Phase Fit

### PASS (120% Commercial Busbar)

Evaluated for 208 V, commercial single-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 8060.0W / 208 V -> 38.8 A | Breaker >= 1.25 * 38.8 = 48.5 A -> 50 A

CEC Inverters.csv for Shenzhen Senergy Technology Co Ltd: SE 8KHB-180-T2/UL {208V}: Paco=8060.0 W, Vac=208 V, Vdcmax=480.0 V, Eff=96.45%.

**Result:** Min 50 A breaker & 8 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).

## What Are the Published CEC Specifications for Shenzhen Senergy Technology Co Ltd: SE 8KHB-180-T2/UL {208V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for Shenzhen Senergy Technology Co Ltd: SE 8KHB-180-T2/UL {208V}.

Official California Energy Commission (NREL SAM) test parameters for Shenzhen Senergy Technology Co Ltd: SE 8KHB-180-T2/UL {208V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 8,060 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 208 V, commercial single-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 480 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 200 V - 480 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 23.2127 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 96.45% | Calculated AC/DC conversion ratio from CEC test protocol |
| **CEC Listing Date & Hybrid** | 2025-04-01 / Hybrid: Yes (Battery Capable) | Utility interconnection approval metadata |

## What Switchgear Limits Apply to Shenzhen Senergy Technology Co Ltd: SE 8KHB-180-T2/UL {208V} (208 V, commercial single-phase)?

Check whether Shenzhen Senergy Technology Co Ltd: SE 8KHB-180-T2/UL {208V} (50 A breaker) fits without main breaker derate or supply-side taps.

Evaluates Shenzhen Senergy Technology Co Ltd: SE 8KHB-180-T2/UL {208V} (50 A required OCPD at 208 V, commercial single-phase) across standard distribution busbars.

| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **200A Bus / 200A Main (208V)** | 40 A | 50 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **400A Bus / 400A Main (208V)** | 80 A | 50 A | PASS (120% Commercial Busbar) |
| **600A Bus / 600A Main (208V)** | 120 A | 50 A | PASS (120% Commercial Busbar) |
| **800A Bus / 800A Main (208V)** | 160 A | 50 A | PASS (120% Commercial Busbar) |
| **1,200A Bus / 1,200A Main (208V)** | 240 A | 50 A | PASS (120% Commercial Busbar) |

## Which CEC PV Module Strings Pair With Shenzhen Senergy Technology Co Ltd: SE 8KHB-180-T2/UL {208V}?

Verified cold-weather (-10 C) series module counts matched to Shenzhen Senergy Technology Co Ltd: SE 8KHB-180-T2/UL {208V}'s 480 V DC ceiling.

Sampled CEC PV modules aligned within 200.0-480.0 V MPPT and 480.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 5 to 8 panels | 4.72 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 6 to 11 panels | 4.84 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 6 to 10 panels | 4.25 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 7 to 11 panels | 2.2 kW |

## Which Competing Grid-Support Inverters Compare to Shenzhen Senergy Technology Co Ltd: SE 8KHB-180-T2/UL {208V}?

Alternative CEC inverters comparable to Shenzhen Senergy Technology Co Ltd: SE 8KHB-180-T2/UL {208V}, including EG4 Electronics LLC: IV-8000-HYB-AW {208V} (7,860 W) at 208 V, commercial single-phase.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**EG4 Electronics LLC: IV-8000-HYB-AW {208V}**](https://epri-peac.com/solar-equipment/inverters/eg4-electronics-llc/eg4-electronics-llc-iv-8000-hyb-aw-208v/) EG4 Electronics LLC | 7,860 W | -200 W | 208.0 V | 480.0 V | 96.27% |
| [**Altenergy Power System Inc: ELS-96 {208V}**](https://epri-peac.com/solar-equipment/inverters/altenergy-power-system-inc/altenergy-power-system-inc-els-96-208v/) Altenergy Power System Inc | 8,308 W | +248 W | 208.0 V | 60.0 V | 93.5% |
| [**Delta Electronics: E10-TL-US(AC) {208V}**](https://epri-peac.com/solar-equipment/inverters/delta-electronics/delta-electronics-e10-tl-us-ac-208v/) Delta Electronics | 8,327 W | +267 W | 208.0 V | 480.0 V | 97.45% |
| [**Delta Electronics: M10-TL-US {208V}**](https://epri-peac.com/solar-equipment/inverters/delta-electronics/delta-electronics-m10-tl-us-208v/) Delta Electronics | 8,360 W | +300 W | 208.0 V | 480.0 V | 96.83% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Shenzhen Senergy Technology Co Ltd: SE 8KHB-180-T2/UL {208V}?

Check Shenzhen Senergy Technology Co Ltd: SE 8KHB-180-T2/UL {208V} (8,060 W AC, 50 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 208 V, commercial single-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on Shenzhen Senergy Technology Co Ltd: SE 8KHB-180-T2/UL {208V}.

### Shenzhen Senergy Technology Co Ltd: SE 8KHB-180-T2/UL {208V} Panel & Wire Spec

Size 75 C copper conductors at 8 AWG Cu on a 50 A OCPD breaker (38.8 A continuous).

### Alternative Inverter Comparison

Compare efficiency (96.45%) and MPPT window (200-480 V) directly against EG4 Electronics LLC: IV-8000-HYB-AW {208V} (7,860 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Shenzhen Senergy Technology Co Ltd: SE 8KHB-180-T2/UL {208V} by Shenzhen Senergy Technology Co Ltd covering breaker sizing, MPPT limits, and 208 V, commercial single-phase interconnection.

### What breaker and wire size does Shenzhen Senergy Technology Co Ltd: SE 8KHB-180-T2/UL {208V} require?

At 8,060 W continuous AC (208 V, commercial single-phase), continuous current is 38.8 A; 125% NEC 690.8/705.12 sizing requires a 50 A breaker and 8 AWG Cu (75 C) wire.

### What commercial switchgear or feeder sizing does Shenzhen Senergy Technology Co Ltd: SE 8KHB-180-T2/UL {208V} require?

At 8,060 W AC and 208 V, commercial single-phase, continuous line current is 38.8 A, requiring a 50 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.

### How does Shenzhen Senergy Technology Co Ltd: SE 8KHB-180-T2/UL {208V} compare to EG4 Electronics LLC: IV-8000-HYB-AW {208V}?

Shenzhen Senergy Technology Co Ltd: SE 8KHB-180-T2/UL {208V} delivers 8,060 W AC at 96.45% CEC efficiency with a 480 V DC ceiling, while EG4 Electronics LLC: IV-8000-HYB-AW {208V} outputs 7,860 W at 208 V, commercial single-phase.

## Related Pages

Explore Shenzhen Senergy Technology Co Ltd hardware, EG4 Electronics LLC: IV-8000-HYB-AW {208V}, utility rates, and NEC 705.12 sizing calculators alongside Shenzhen Senergy Technology Co Ltd: SE 8KHB-180-T2/UL {208V}.

[All Shenzhen Senergy Technology Co Ltd Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/shenzhen-senergy-technology-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Shenzhen Senergy Technology Co Ltd

- [All Shenzhen Senergy Technology Co Ltd Specs](https://epri-peac.com/solar-equipment/brands/shenzhen-senergy-technology-co-ltd/)
- [Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {208V}](https://epri-peac.com/solar-equipment/inverters/shenzhen-senergy-technology-co-ltd/shenzhen-senergy-technology-co-ltd-se-11k4hb-t2-lv-ulp-208v/)
- [Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V}](https://epri-peac.com/solar-equipment/inverters/shenzhen-senergy-technology-co-ltd/shenzhen-senergy-technology-co-ltd-se-11k4hb-t2-lv-ulp-240v/)
- [Shenzhen Senergy Technology Co Ltd: SE 11K4HB-210-T2/UL {208V}](https://epri-peac.com/solar-equipment/inverters/shenzhen-senergy-technology-co-ltd/shenzhen-senergy-technology-co-ltd-se-11k4hb-210-t2-ul-208v/)
- [Shenzhen Senergy Technology Co Ltd: SE 10KHB-210-T2/UL {208V}](https://epri-peac.com/solar-equipment/inverters/shenzhen-senergy-technology-co-ltd/shenzhen-senergy-technology-co-ltd-se-10khb-210-t2-ul-208v/)
- [Shenzhen Senergy Technology Co Ltd: SE 10KHB-210-T2/UL {240V}](https://epri-peac.com/solar-equipment/inverters/shenzhen-senergy-technology-co-ltd/shenzhen-senergy-technology-co-ltd-se-10khb-210-t2-ul-240v/)