title: "Shenzhen Senergy Technology Co Inverter (11,567W)"
url: https://epri-peac.com/solar-equipment/inverters/shenzhen-senergy-technology-co-ltd/shenzhen-senergy-technology-co-ltd-se-11k4hb-t2-lv-ulp-240v/
description: "CEC specs for Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V}: 11,567W AC, 240V, 70A OCPD, and NEC 705.12 checks."
---

CEC Grid-Support Inverter

# Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V} — CEC Inverter Specifications

Manufacturer: [**Shenzhen Senergy Technology Co Ltd**](https://epri-peac.com/solar-equipment/brands/shenzhen-senergy-technology-co-ltd/) Registry: **CEC Verified Engineering Specification**

Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V} outputs 11,567 W AC at 240 V (48.2 A continuous, 70 A OCPD), ranking #1,467 of 2,343 CEC inverters at 96.56% efficiency with a 200-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 11,567 W

- **AC Voltage** : 240 V

- **Min PV Breaker** : 70 A (4 AWG Cu)

- **CEC Efficiency** : 96.56%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 240 V grid-support overview for Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V}.

Rated at 11,567 W AC (48.2 A continuous), Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V} ranks #1,467 of 2,343 CEC units at 96.56% efficiency (-0.12 pts vs the 96.68% 240 V median). Minimum 75 C copper conductor sizing for its 70 A circuit is 4 AWG Cu per NEC Table 310.16. Cold-weather string Voc must remain under 480 V DC at record local winter lows.

## Where Does Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V} Fall Across Listed CEC Models?

Marks Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V} (11,567 W AC) across the California Energy Commission inverter AC capacity distribution.

## What Dataset Percentiles Define Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V}?

Benchmarks Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V} continuous AC output, 96.56% CEC weighted efficiency, and 70 A OCPD breaker demand.

## What Do the Dataset Ranks Show for Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V}?

Four key NEC 705.12 and California Energy Commission metrics defining Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V} by Shenzhen Senergy Technology Co Ltd.

Eff #1,467 / 2,343

### 96.56% CEC Weighted Efficiency

-0.12 pts vs the 96.68% 240 V median; overall power rank #756 (11,567 W, top 32.3%; higher than 67.7% of peers).

NEC 705.12 Check

### 70 A Required Backfeed OCPD

125% x 48.2 A = 60.2 A -> 70 A standard OCPD using 4 AWG Cu (75 C).

MPPT Window

### 200 V - 480 V (Max 480 V DC)

Tracking span of 280.0 V; active in CEC directory (hybrid battery-capable inverter).

Panel Fit (240V)

### Needs Derate / Tap 705.11

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 11566.9W / 240 V -> 48.2 A | Breaker >= 1.25 * 48.2 = 60.2 A -> 70 A

CEC Inverters.csv for Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V}: Paco=11566.9 W, Vac=240 V, Vdcmax=480.0 V, Eff=96.56%.

**Result:** Min 70 A breaker & 4 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.

## What Are the Published CEC Specifications for Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V}.

Official California Energy Commission (NREL SAM) test parameters for Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 11,567 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 480 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 200 V - 480 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 33.276 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 96.56% | Calculated AC/DC conversion ratio from CEC test protocol |
| **Inverter Topology** | Hybrid: Yes (Battery Capable) | CEC Solar Equipment List grid-support certification |

## Can a Residential Panel Meet 120% Busbar Limits for Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V}?

Evaluates Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V} (70 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V} (70 A required OCPD at 240 V) across standard distribution busbars.

| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **100A Bus / 100A Main** | 20 A | 70 A | Needs Derate / Tap 705.11 |
| **150A Bus / 150A Main** | 30 A | 70 A | Needs Derate / Tap 705.11 |
| **200A Bus / 200A Main** | 40 A | 70 A | Needs Derate / Tap 705.11 |
| **200A Bus / 175A Main** | 65 A | 70 A | Needs Derate / Tap 705.11 |
| **225A Bus / 200A Main** | 70 A | 70 A | PASS (120% Rule) |

## Which CEC PV Module Strings Pair With Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V}?

Sample PV string lengths aligned within 200-480 V MPPT and 480 V DC max at -10 C. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Sampled CEC PV modules aligned within 200.0-480.0 V MPPT and 480.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 5 to 8 panels | 4.72 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 6 to 11 panels | 4.84 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 6 to 10 panels | 4.25 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 7 to 11 panels | 2.2 kW |

## Which Competing Grid-Support Inverters Compare to Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V}?

Competing CEC grid-support inverters near 11,567 W AC and 240 V, led by Delta Electronics: S12_BDI {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Delta Electronics: S12_BDI {240V}**](https://epri-peac.com/solar-equipment/inverters/delta-electronics/delta-electronics-s12-bdi-240v/) Delta Electronics | 11,589 W | +22 W | 240.0 V | 480.0 V | 96.99% |
| [**Base Power Inc: MIN 11400TL-XH-US {240V}**](https://epri-peac.com/solar-equipment/inverters/base-power-inc/base-power-inc-min-11400tl-xh-us-240v/) Base Power Inc | 11,520 W | -47 W | 240.0 V | 480.0 V | 97.76% |
| [**Dyness Digital Energy Technology Co LTD: TX114K-AM {240V}**](https://epri-peac.com/solar-equipment/inverters/dyness-digital-energy-technology-co-ltd/dyness-digital-energy-technology-co-ltd-tx114k-am-240v/) Dyness Digital Energy Technology Co LTD | 11,519 W | -48 W | 240.0 V | 490.0 V | 96.21% |
| [**Dyness Digital Energy Technology Co LTD: TX114K-HM {240V}**](https://epri-peac.com/solar-equipment/inverters/dyness-digital-energy-technology-co-ltd/dyness-digital-energy-technology-co-ltd-tx114k-hm-240v/) Dyness Digital Energy Technology Co LTD | 11,498 W | -69 W | 240.0 V | 500.0 V | 96.41% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V}?

Check Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V} (11,567 W AC, 70 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Its 70 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V}.

### Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V} Panel & Wire Spec

Size 75 C copper conductors at 4 AWG Cu on a 70 A OCPD breaker (48.2 A continuous).

### Alternative Inverter Comparison

Compare efficiency (96.56%) and MPPT window (200-480 V) directly against Delta Electronics: S12_BDI {240V} (11,589 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V} by Shenzhen Senergy Technology Co Ltd covering breaker sizing, MPPT limits, and 240 V interconnection.

### What breaker and wire size does Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V} require?

At 11,567 W continuous AC (240 V), continuous current is 48.2 A; 125% NEC 690.8/705.12 sizing requires a 70 A breaker and 4 AWG Cu (75 C) wire.

### Does Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 70 A at 240 V means Needs Derate / Tap 705.11.

### How does Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V} compare to Delta Electronics: S12_BDI {240V}?

Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V} delivers 11,567 W AC at 96.56% CEC efficiency with a 480 V DC ceiling, while Delta Electronics: S12_BDI {240V} outputs 11,589 W at 240 V.

## Related Pages

Explore Shenzhen Senergy Technology Co Ltd hardware, Delta Electronics: S12_BDI {240V}, utility rates, and NEC 705.12 sizing calculators alongside Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V}.

[All Shenzhen Senergy Technology Co Ltd Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/shenzhen-senergy-technology-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Shenzhen Senergy Technology Co Ltd

- [All Shenzhen Senergy Technology Co Ltd Specs](https://epri-peac.com/solar-equipment/brands/shenzhen-senergy-technology-co-ltd/)
- [Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {208V}](https://epri-peac.com/solar-equipment/inverters/shenzhen-senergy-technology-co-ltd/shenzhen-senergy-technology-co-ltd-se-11k4hb-t2-lv-ulp-208v/)
- [Shenzhen Senergy Technology Co Ltd: SE 11K4HB-210-T2/UL {208V}](https://epri-peac.com/solar-equipment/inverters/shenzhen-senergy-technology-co-ltd/shenzhen-senergy-technology-co-ltd-se-11k4hb-210-t2-ul-208v/)
- [Shenzhen Senergy Technology Co Ltd: SE 10KHB-210-T2/UL {208V}](https://epri-peac.com/solar-equipment/inverters/shenzhen-senergy-technology-co-ltd/shenzhen-senergy-technology-co-ltd-se-10khb-210-t2-ul-208v/)
- [Shenzhen Senergy Technology Co Ltd: SE 10KHB-210-T2/UL {240V}](https://epri-peac.com/solar-equipment/inverters/shenzhen-senergy-technology-co-ltd/shenzhen-senergy-technology-co-ltd-se-10khb-210-t2-ul-240v/)
- [Shenzhen Senergy Technology Co Ltd: SE 11K4HB-210-T2/UL {240V}](https://epri-peac.com/solar-equipment/inverters/shenzhen-senergy-technology-co-ltd/shenzhen-senergy-technology-co-ltd-se-11k4hb-210-t2-ul-240v/)