title: "Schneider Electric USA Inc: XW Inverter (6,019W)"
url: https://epri-peac.com/solar-equipment/inverters/schneider-electric-usa-inc/schneider-electric-usa-inc-xw-pro-6848-na-240v/
description: "CEC specs for Schneider Electric USA Inc: XW Pro 6848 NA {240V}: 6,019W AC, 240V, 35A OCPD, and NEC 705.12 checks. Source-verified US engineering data."
---

CEC Grid-Support Inverter

# Schneider Electric USA Inc: XW Pro 6848 NA {240V} — CEC Inverter Specifications

Manufacturer: [**Schneider Electric USA Inc**](https://epri-peac.com/solar-equipment/brands/schneider-electric-usa-inc/) Registry: **CEC Verified Engineering Specification**

Schneider Electric USA Inc: XW Pro 6848 NA {240V} outputs 6,019 W AC at 240 V (25.1 A continuous, 35 A OCPD), ranking #2,332 of 2,343 CEC inverters at 92.2% efficiency with a 47-58 V MPPT window and 58 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 6,019 W

- **AC Voltage** : 240 V

- **Min PV Breaker** : 35 A (8 AWG Cu)

- **CEC Efficiency** : 92.2%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Schneider Electric USA Inc: XW Pro 6848 NA {240V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 240 V grid-support overview for Schneider Electric USA Inc: XW Pro 6848 NA {240V}.

Ranking #1,374 of 2,343 CEC inverters (below CEC median; higher than 41.4% of peers), Schneider Electric USA Inc: XW Pro 6848 NA {240V} is a grid-tied PV inverter delivering 6,019 W continuous AC at 240 V (25.1 A continuous). Requires a 35 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit). Weighted CEC efficiency reaches 92.2% (-4.48 pts vs the 96.68% 240 V median) against peers like Dyness Digital Energy Technology Co LTD: TX6K-HM {240V} (6,018 W).

## Where Does Schneider Electric USA Inc: XW Pro 6848 NA {240V} Fall Across Listed CEC Models?

Marks Schneider Electric USA Inc: XW Pro 6848 NA {240V} (6,019 W AC) across the California Energy Commission inverter AC capacity distribution.

## What Dataset Percentiles Define Schneider Electric USA Inc: XW Pro 6848 NA {240V}?

Benchmarks Schneider Electric USA Inc: XW Pro 6848 NA {240V} continuous AC output, 92.2% CEC weighted efficiency, and 35 A OCPD breaker demand.

## What Do the Dataset Ranks Show for Schneider Electric USA Inc: XW Pro 6848 NA {240V}?

Four key NEC 705.12 and California Energy Commission metrics defining Schneider Electric USA Inc: XW Pro 6848 NA {240V} by Schneider Electric USA Inc.

Eff #2,332 / 2,343

### 92.2% CEC Weighted Efficiency

-4.48 pts vs the 96.68% 240 V median; overall power rank #1,374 (6,019 W, below CEC median; higher than 41.4% of peers).

NEC 705.12 Check

### 35 A Required Backfeed OCPD

125% x 25.1 A = 31.4 A -> 35 A standard OCPD using 8 AWG Cu (75 C).

MPPT Window

### 47 V - 58 V (Max 58 V DC)

Tracking span of 11.0 V; listed since 2024-04-02 (grid-tied PV inverter).

Panel Fit (240V)

### PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 6019.0W / 240 V -> 25.1 A | Breaker >= 1.25 * 25.1 = 31.4 A -> 35 A

CEC Inverters.csv for Schneider Electric USA Inc: XW Pro 6848 NA {240V}: Paco=6019.0 W, Vac=240 V, Vdcmax=58.0 V, Eff=92.2%.

**Result:** Min 35 A breaker & 8 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

## What Are the Published CEC Specifications for Schneider Electric USA Inc: XW Pro 6848 NA {240V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for Schneider Electric USA Inc: XW Pro 6848 NA {240V}.

Official California Energy Commission (NREL SAM) test parameters for Schneider Electric USA Inc: XW Pro 6848 NA {240V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 6,019 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 58 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 47 V - 58 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 125.544 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 92.2% | Calculated AC/DC conversion ratio from CEC test protocol |
| **CEC Listing Date & Hybrid** | 2024-04-02 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |

## Can a Residential Panel Meet 120% Busbar Limits for Schneider Electric USA Inc: XW Pro 6848 NA {240V}?

Evaluates Schneider Electric USA Inc: XW Pro 6848 NA {240V} (35 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates Schneider Electric USA Inc: XW Pro 6848 NA {240V} (35 A required OCPD at 240 V) across standard distribution busbars.

| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **100A Bus / 100A Main** | 20 A | 35 A | Needs Derate / Tap 705.11 |
| **150A Bus / 150A Main** | 30 A | 35 A | Needs Derate / Tap 705.11 |
| **200A Bus / 200A Main** | 40 A | 35 A | PASS (120% Rule) |
| **200A Bus / 175A Main** | 65 A | 35 A | PASS (120% Rule) |
| **225A Bus / 200A Main** | 70 A | 35 A | PASS (120% Rule) |

## Which CEC PV Module Strings Pair With Schneider Electric USA Inc: XW Pro 6848 NA {240V}?

Sample PV string lengths aligned within 47-58 V MPPT and 58 V DC max at -10 C. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Sampled CEC PV modules aligned within 47.0-58.0 V MPPT and 58.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 1 panel (micro/module) | 0.59 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 1 panel (micro/module) | 0.44 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 1 panel (micro/module) | 0.42 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 1 panel (micro/module) | 0.2 kW |

## Which Competing Grid-Support Inverters Compare to Schneider Electric USA Inc: XW Pro 6848 NA {240V}?

Competing CEC grid-support inverters near 6,019 W AC and 240 V, led by Dyness Digital Energy Technology Co LTD: TX6K-HM {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Dyness Digital Energy Technology Co LTD: TX6K-HM {240V}**](https://epri-peac.com/solar-equipment/inverters/dyness-digital-energy-technology-co-ltd/dyness-digital-energy-technology-co-ltd-tx6k-hm-240v/) Dyness Digital Energy Technology Co LTD | 6,018 W | -1 W | 240.0 V | 500.0 V | 97.0% |
| [**Dyness Digital Energy Technology Co LTD: TX6K-AM {240V}**](https://epri-peac.com/solar-equipment/inverters/dyness-digital-energy-technology-co-ltd/dyness-digital-energy-technology-co-ltd-tx6k-am-240v/) Dyness Digital Energy Technology Co LTD | 6,028 W | +9 W | 240.0 V | 490.0 V | 96.68% |
| [**ABB: PVI-6000-OUTD-US-A {240V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-pvi-6000-outd-us-a-240v/) ABB | 6,000 W | -19 W | 240.0 V | 480.0 V | 96.21% |
| [**ABB: PVI-6000-OUTD-US-Z-A {240V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-pvi-6000-outd-us-z-a-240v/) ABB | 6,000 W | -19 W | 240.0 V | 480.0 V | 96.21% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Schneider Electric USA Inc: XW Pro 6848 NA {240V}?

Check Schneider Electric USA Inc: XW Pro 6848 NA {240V} (6,019 W AC, 35 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Requires a 35 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 58 V DC on Schneider Electric USA Inc: XW Pro 6848 NA {240V}.

### Schneider Electric USA Inc: XW Pro 6848 NA {240V} Panel & Wire Spec

Size 75 C copper conductors at 8 AWG Cu on a 35 A OCPD breaker (25.1 A continuous).

### Alternative Inverter Comparison

Compare efficiency (92.2%) and MPPT window (47-58 V) directly against Dyness Digital Energy Technology Co LTD: TX6K-HM {240V} (6,018 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Schneider Electric USA Inc: XW Pro 6848 NA {240V} by Schneider Electric USA Inc covering breaker sizing, MPPT limits, and 240 V interconnection.

### What breaker and wire size does Schneider Electric USA Inc: XW Pro 6848 NA {240V} require?

At 6,019 W continuous AC (240 V), continuous current is 25.1 A; 125% NEC 690.8/705.12 sizing requires a 35 A breaker and 8 AWG Cu (75 C) wire.

### Does Schneider Electric USA Inc: XW Pro 6848 NA {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 35 A at 240 V means PASS (120% Rule).

### How does Schneider Electric USA Inc: XW Pro 6848 NA {240V} compare to Dyness Digital Energy Technology Co LTD: TX6K-HM {240V}?

Schneider Electric USA Inc: XW Pro 6848 NA {240V} delivers 6,019 W AC at 92.2% CEC efficiency with a 58 V DC ceiling, while Dyness Digital Energy Technology Co LTD: TX6K-HM {240V} outputs 6,018 W at 240 V.

## Related Pages

Explore Schneider Electric USA Inc hardware, Dyness Digital Energy Technology Co LTD: TX6K-HM {240V}, utility rates, and NEC 705.12 sizing calculators alongside Schneider Electric USA Inc: XW Pro 6848 NA {240V}.

[All Schneider Electric USA Inc Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/schneider-electric-usa-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Schneider Electric USA Inc

- [All Schneider Electric USA Inc Specs](https://epri-peac.com/solar-equipment/brands/schneider-electric-usa-inc/)
- [Schneider Electric USA Inc: CS2200-NA {600V}](https://epri-peac.com/solar-equipment/inverters/schneider-electric-usa-inc/schneider-electric-usa-inc-cs2200-na-600v/)
- [Schneider Electric USA Inc: CS2000-NA {575V}](https://epri-peac.com/solar-equipment/inverters/schneider-electric-usa-inc/schneider-electric-usa-inc-cs2000-na-575v/)
- [Schneider Electric USA Inc: CS1800-NA {575V}](https://epri-peac.com/solar-equipment/inverters/schneider-electric-usa-inc/schneider-electric-usa-inc-cs1800-na-575v/)
- [Schneider Electric USA Inc: CS1666-1-NA {575V}](https://epri-peac.com/solar-equipment/inverters/schneider-electric-usa-inc/schneider-electric-usa-inc-cs1666-1-na-575v/)
- [Schneider Electric USA Inc: CS1666-2-NA {575V}](https://epri-peac.com/solar-equipment/inverters/schneider-electric-usa-inc/schneider-electric-usa-inc-cs1666-2-na-575v/)