CEC Grid-Support Inverter

# Schneider Electric USA Inc: XW Pro 6848 NA {120V} — CEC Inverter Specifications

Manufacturer: [**Schneider Electric USA Inc**](https://epri-peac.com/solar-equipment/brands/schneider-electric-usa-inc/) Registry: **CEC Verified Engineering Specification**

Schneider Electric USA Inc: XW Pro 6848 NA {120V} outputs 5,747 W AC at 120 V (47.9 A continuous, 60 A OCPD), ranking #2,333 of 2,343 CEC inverters at 91.96% efficiency with a 47-58 V MPPT window and 58 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 5,747 W

- **AC Voltage** : 120 V

- **Min PV Breaker** : 60 A (6 AWG Cu)

- **CEC Efficiency** : 91.96%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Schneider Electric USA Inc: XW Pro 6848 NA {120V} Compare Against Peer CEC Listings?

How Schneider Electric USA Inc Schneider Electric USA Inc: XW Pro 6848 NA {120V} compares on 91.96% efficiency, MPPT span, and 120% busbar interconnection.

With a 47-58 V MPPT tracking band and 58 V DC ceiling, Schneider Electric USA Inc: XW Pro 6848 NA {120V} handles 5,747 W continuous AC (480 W above the 5,267 W 120 V median). Its 60 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap. Installers comparing Schneider Electric USA Inc against Fengfan Co Ltd Power Supply Branch: SPT-OMOBFP1-A-6KW {120V} (6,018 W) should verify whether listed since 2024-04-02 grid-support firmware meets local IEEE 1547 utility rules.

## Where Does Schneider Electric USA Inc: XW Pro 6848 NA {120V} Fall Across Listed CEC Models?

Position of Schneider Electric USA Inc: XW Pro 6848 NA {120V} (5,747 W AC) relative to the 7,680 W CEC median inverter.

## What Dataset Percentiles Define Schneider Electric USA Inc: XW Pro 6848 NA {120V}?

Percentile placement of Schneider Electric USA Inc: XW Pro 6848 NA {120V} across AC power class, conversion efficiency, and backfeed breaker size.

## What Do the Dataset Ranks Show for Schneider Electric USA Inc: XW Pro 6848 NA {120V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for Schneider Electric USA Inc: XW Pro 6848 NA {120V}.

Eff #2,333 / 2,343

### 91.96% CEC Weighted Efficiency

-2.77 pts vs the 94.73% 120 V median; overall power rank #1,441 (5,747 W, below CEC median; higher than 38.5% of peers).

NEC 705.12 Check

### 60 A Required Backfeed OCPD

125% x 47.9 A = 59.9 A -> 60 A standard OCPD using 6 AWG Cu (75 C).

MPPT Window

### 47 V - 58 V (Max 58 V DC)

Tracking span of 11.0 V; listed since 2024-04-02 (grid-tied PV inverter).

Panel Fit (240V)

### 120V AC Coupled / Dedicated Transformer

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 5747.0W / 120 V -> 47.9 A | Breaker >= 1.25 * 47.9 = 59.9 A -> 60 A

CEC Inverters.csv for Schneider Electric USA Inc: XW Pro 6848 NA {120V}: Paco=5747.0 W, Vac=120 V, Vdcmax=58.0 V, Eff=91.96%.

**Result:** Min 60 A breaker & 6 AWG Cu (75 C); 200A Bus / 200A Main: 120V AC Coupled / Dedicated Transformer.

## What Are the Published CEC Specifications for Schneider Electric USA Inc: XW Pro 6848 NA {120V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for Schneider Electric USA Inc: XW Pro 6848 NA {120V}.

Official California Energy Commission (NREL SAM) test parameters for Schneider Electric USA Inc: XW Pro 6848 NA {120V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 5,747 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 120 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 58 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 47 V - 58 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 120.18 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 91.96% | Calculated AC/DC conversion ratio from CEC test protocol |
| **CEC Listing Date & Hybrid** | 2024-04-02 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |

## Can a Residential Panel Meet 120% Busbar Limits for Schneider Electric USA Inc: XW Pro 6848 NA {120V}?

Check whether Schneider Electric USA Inc: XW Pro 6848 NA {120V} (60 A breaker) fits without main breaker derate or supply-side taps.

Evaluates Schneider Electric USA Inc: XW Pro 6848 NA {120V} (60 A required OCPD at 120 V) across standard distribution busbars.

| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **100A Bus / 100A Main** | 20 A | 60 A | 120V AC Coupled / Dedicated Transformer |
| **150A Bus / 150A Main** | 30 A | 60 A | 120V AC Coupled / Dedicated Transformer |
| **200A Bus / 200A Main** | 40 A | 60 A | 120V AC Coupled / Dedicated Transformer |
| **200A Bus / 175A Main** | 65 A | 60 A | 120V AC Coupled / Dedicated Transformer |
| **225A Bus / 200A Main** | 70 A | 60 A | 120V AC Coupled / Dedicated Transformer |

## Which CEC PV Module Strings Pair With Schneider Electric USA Inc: XW Pro 6848 NA {120V}?

Verified cold-weather (-10 C) series module counts matched to Schneider Electric USA Inc: XW Pro 6848 NA {120V}'s 58 V DC ceiling.

Sampled CEC PV modules aligned within 47.0-58.0 V MPPT and 58.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 1 panel (micro/module) | 0.59 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 1 panel (micro/module) | 0.44 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 1 panel (micro/module) | 0.42 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 1 panel (micro/module) | 0.2 kW |

## Which Competing Grid-Support Inverters Compare to Schneider Electric USA Inc: XW Pro 6848 NA {120V}?

Alternative CEC inverters comparable to Schneider Electric USA Inc: XW Pro 6848 NA {120V}, including Fengfan Co Ltd Power Supply Branch: SPT-OMOBFP1-A-6KW {120V} (6,018 W) at 120 V.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Fengfan Co Ltd Power Supply Branch: SPT-OMOBFP1-A-6KW {120V}**](https://epri-peac.com/solar-equipment/inverters/fengfan-co-ltd-power-supply-branch/fengfan-co-ltd-power-supply-branch-spt-omobfp1-a-6kw-120v/) Fengfan Co Ltd Power Supply Branch | 6,018 W | +271 W | 120.0 V | 500.0 V | 94.55% |
| [**SimpliPhi Power: SPHI-IN-6 {120V}**](https://epri-peac.com/solar-equipment/inverters/simpliphi-power/simpliphi-power-sphi-in-6-120v/) SimpliPhi Power | 6,018 W | +271 W | 120.0 V | 500.0 V | 94.55% |
| [**VOLTRONIC POWER TECHNOLOGY (SHENZHEN) CORP: InfiniSolar WP LV 6KW {120V}**](https://epri-peac.com/solar-equipment/inverters/voltronic-power-technology-shenzhen-corp/voltronic-power-technology-shenzhen-corp-infinisolar-wp-lv-6kw-120v/) VOLTRONIC POWER TECHNOLOGY (SHENZHEN) CORP | 6,018 W | +271 W | 120.0 V | 500.0 V | 94.54% |
| [**Power Center: Essential Hybrid 5 {120V}**](https://epri-peac.com/solar-equipment/inverters/power-center/power-center-essential-hybrid-5-120v/) Power Center | 4,787 W | -960 W | 120.0 V | 425.0 V | 95.59% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Schneider Electric USA Inc: XW Pro 6848 NA {120V}?

Check Schneider Electric USA Inc: XW Pro 6848 NA {120V} (5,747 W AC, 60 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Its 60 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 58 V DC on Schneider Electric USA Inc: XW Pro 6848 NA {120V}.

### Schneider Electric USA Inc: XW Pro 6848 NA {120V} Panel & Wire Spec

Size 75 C copper conductors at 6 AWG Cu on a 60 A OCPD breaker (47.9 A continuous).

### Alternative Inverter Comparison

Compare efficiency (91.96%) and MPPT window (47-58 V) directly against Fengfan Co Ltd Power Supply Branch: SPT-OMOBFP1-A-6KW {120V} (6,018 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Schneider Electric USA Inc: XW Pro 6848 NA {120V} by Schneider Electric USA Inc covering breaker sizing, MPPT limits, and 120 V interconnection.

### What breaker and wire size does Schneider Electric USA Inc: XW Pro 6848 NA {120V} require?

At 5,747 W continuous AC (120 V), continuous current is 47.9 A; 125% NEC 690.8/705.12 sizing requires a 60 A breaker and 6 AWG Cu (75 C) wire.

### Does Schneider Electric USA Inc: XW Pro 6848 NA {120V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 60 A at 120 V means 120V AC Coupled / Dedicated Transformer.

### How does Schneider Electric USA Inc: XW Pro 6848 NA {120V} compare to Fengfan Co Ltd Power Supply Branch: SPT-OMOBFP1-A-6KW {120V}?

Schneider Electric USA Inc: XW Pro 6848 NA {120V} delivers 5,747 W AC at 91.96% CEC efficiency with a 58 V DC ceiling, while Fengfan Co Ltd Power Supply Branch: SPT-OMOBFP1-A-6KW {120V} outputs 6,018 W at 120 V.

## Related Pages

Explore Schneider Electric USA Inc hardware, Fengfan Co Ltd Power Supply Branch: SPT-OMOBFP1-A-6KW {120V}, utility rates, and NEC 705.12 sizing calculators alongside Schneider Electric USA Inc: XW Pro 6848 NA {120V}.

[All Schneider Electric USA Inc Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/schneider-electric-usa-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Schneider Electric USA Inc

- [All Schneider Electric USA Inc Specs](https://epri-peac.com/solar-equipment/brands/schneider-electric-usa-inc/)
- [Schneider Electric USA Inc: CS2200-NA {600V}](https://epri-peac.com/solar-equipment/inverters/schneider-electric-usa-inc/schneider-electric-usa-inc-cs2200-na-600v/)
- [Schneider Electric USA Inc: CS2000-NA {575V}](https://epri-peac.com/solar-equipment/inverters/schneider-electric-usa-inc/schneider-electric-usa-inc-cs2000-na-575v/)
- [Schneider Electric USA Inc: CS1800-NA {575V}](https://epri-peac.com/solar-equipment/inverters/schneider-electric-usa-inc/schneider-electric-usa-inc-cs1800-na-575v/)
- [Schneider Electric USA Inc: CS1666-1-NA {575V}](https://epri-peac.com/solar-equipment/inverters/schneider-electric-usa-inc/schneider-electric-usa-inc-cs1666-1-na-575v/)
- [Schneider Electric USA Inc: CS1666-2-NA {575V}](https://epri-peac.com/solar-equipment/inverters/schneider-electric-usa-inc/schneider-electric-usa-inc-cs1666-2-na-575v/)