CEC Grid-Support Inverter

# Schneider Electric USA Inc: HY8K1NA1 {240V} — CEC Inverter Specifications

Manufacturer: [**Schneider Electric USA Inc**](https://epri-peac.com/solar-equipment/brands/schneider-electric-usa-inc/) Registry: **CEC Verified Engineering Specification**

Schneider Electric USA Inc: HY8K1NA1 {240V} outputs 7,626 W AC at 240 V (31.8 A continuous, 40 A OCPD), ranking #808 of 2,343 CEC inverters at 97.16% efficiency with a 200-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 7,626 W

- **AC Voltage** : 240 V

- **Min PV Breaker** : 40 A (8 AWG Cu)

- **CEC Efficiency** : 97.16%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Schneider Electric USA Inc: HY8K1NA1 {240V} Compare Against Peer CEC Listings?

How Schneider Electric USA Inc Schneider Electric USA Inc: HY8K1NA1 {240V} compares on 97.16% efficiency, MPPT span, and 120% busbar interconnection.

With a 200-480 V MPPT tracking band and 480 V DC ceiling, Schneider Electric USA Inc: HY8K1NA1 {240V} handles 7,626 W continuous AC (1,850 W above the 5,776 W 240 V median). Requires a 40 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit). Installers comparing Schneider Electric USA Inc against dcbel Inc: Dcbel Ara (DBHS-ARxx-xx) {240V} (7,624 W) should verify whether listed since 2025-09-22 grid-support firmware meets local IEEE 1547 utility rules.

## Where Does Schneider Electric USA Inc: HY8K1NA1 {240V} Fall Across Listed CEC Models?

Position of Schneider Electric USA Inc: HY8K1NA1 {240V} (7,626 W AC) relative to the 7,680 W CEC median inverter.

## What Dataset Percentiles Define Schneider Electric USA Inc: HY8K1NA1 {240V}?

Percentile placement of Schneider Electric USA Inc: HY8K1NA1 {240V} across AC power class, conversion efficiency, and backfeed breaker size.

## What Do the Dataset Ranks Show for Schneider Electric USA Inc: HY8K1NA1 {240V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for Schneider Electric USA Inc: HY8K1NA1 {240V}.

Eff #808 / 2,343

### 97.16% CEC Weighted Efficiency

+0.48 pts vs the 96.68% 240 V median; overall power rank #1,208 (7,626 W, below CEC median; higher than 48.4% of peers).

NEC 705.12 Check

### 40 A Required Backfeed OCPD

125% x 31.8 A = 39.8 A -> 40 A standard OCPD using 8 AWG Cu (75 C).

MPPT Window

### 200 V - 480 V (Max 480 V DC)

Tracking span of 280.0 V; listed since 2025-09-22 (hybrid battery-capable inverter).

Panel Fit (240V)

### PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 7626.0W / 240 V -> 31.8 A | Breaker >= 1.25 * 31.8 = 39.8 A -> 40 A

CEC Inverters.csv for Schneider Electric USA Inc: HY8K1NA1 {240V}: Paco=7626.0 W, Vac=240 V, Vdcmax=480.0 V, Eff=97.16%.

**Result:** Min 40 A breaker & 8 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

## What Are the Published CEC Specifications for Schneider Electric USA Inc: HY8K1NA1 {240V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for Schneider Electric USA Inc: HY8K1NA1 {240V}.

Official California Energy Commission (NREL SAM) test parameters for Schneider Electric USA Inc: HY8K1NA1 {240V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 7,626 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 480 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 200 V - 480 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 21.8035 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 97.16% | Calculated AC/DC conversion ratio from CEC test protocol |
| **CEC Listing Date & Hybrid** | 2025-09-22 / Hybrid: Yes (Battery Capable) | Utility interconnection approval metadata |

## Can a Residential Panel Meet 120% Busbar Limits for Schneider Electric USA Inc: HY8K1NA1 {240V}?

Check whether Schneider Electric USA Inc: HY8K1NA1 {240V} (40 A breaker) fits without main breaker derate or supply-side taps.

Evaluates Schneider Electric USA Inc: HY8K1NA1 {240V} (40 A required OCPD at 240 V) across standard distribution busbars.

| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **100A Bus / 100A Main** | 20 A | 40 A | Needs Derate / Tap 705.11 |
| **150A Bus / 150A Main** | 30 A | 40 A | Needs Derate / Tap 705.11 |
| **200A Bus / 200A Main** | 40 A | 40 A | PASS (120% Rule) |
| **200A Bus / 175A Main** | 65 A | 40 A | PASS (120% Rule) |
| **225A Bus / 200A Main** | 70 A | 40 A | PASS (120% Rule) |

## Which CEC PV Module Strings Pair With Schneider Electric USA Inc: HY8K1NA1 {240V}?

Verified cold-weather (-10 C) series module counts matched to Schneider Electric USA Inc: HY8K1NA1 {240V}'s 480 V DC ceiling.

Sampled CEC PV modules aligned within 200.0-480.0 V MPPT and 480.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 5 to 8 panels | 4.72 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 6 to 11 panels | 4.84 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 6 to 10 panels | 4.25 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 7 to 11 panels | 2.2 kW |

## Which Competing Grid-Support Inverters Compare to Schneider Electric USA Inc: HY8K1NA1 {240V}?

Alternative CEC inverters comparable to Schneider Electric USA Inc: HY8K1NA1 {240V}, including dcbel Inc: Dcbel Ara (DBHS-ARxx-xx) {240V} (7,624 W) at 240 V.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**dcbel Inc: Dcbel Ara (DBHS-ARxx-xx) {240V}**](https://epri-peac.com/solar-equipment/inverters/dcbel-inc/dcbel-inc-dcbel-ara-dbhs-arxx-xx-240v/) dcbel Inc | 7,624 W | -2 W | 240.0 V | 470.0 V | 91.94% |
| [**Dyness Digital Energy Technology Co LTD: TX76K-AM {240V}**](https://epri-peac.com/solar-equipment/inverters/dyness-digital-energy-technology-co-ltd/dyness-digital-energy-technology-co-ltd-tx76k-am-240v/) Dyness Digital Energy Technology Co LTD | 7,636 W | +10 W | 240.0 V | 490.0 V | 96.56% |
| [**Dyness Digital Energy Technology Co LTD: TX76K-HM {240V}**](https://epri-peac.com/solar-equipment/inverters/dyness-digital-energy-technology-co-ltd/dyness-digital-energy-technology-co-ltd-tx76k-hm-240v/) Dyness Digital Energy Technology Co LTD | 7,640 W | +14 W | 240.0 V | 500.0 V | 96.84% |
| [**Altenergy Power System Inc: ELS-76 {240V}**](https://epri-peac.com/solar-equipment/inverters/altenergy-power-system-inc/altenergy-power-system-inc-els-76-240v/) Altenergy Power System Inc | 7,609 W | -17 W | 240.0 V | 60.0 V | 94.31% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Schneider Electric USA Inc: HY8K1NA1 {240V}?

Check Schneider Electric USA Inc: HY8K1NA1 {240V} (7,626 W AC, 40 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Requires a 40 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on Schneider Electric USA Inc: HY8K1NA1 {240V}.

### Schneider Electric USA Inc: HY8K1NA1 {240V} Panel & Wire Spec

Size 75 C copper conductors at 8 AWG Cu on a 40 A OCPD breaker (31.8 A continuous).

### Alternative Inverter Comparison

Compare efficiency (97.16%) and MPPT window (200-480 V) directly against dcbel Inc: Dcbel Ara (DBHS-ARxx-xx) {240V} (7,624 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Schneider Electric USA Inc: HY8K1NA1 {240V} by Schneider Electric USA Inc covering breaker sizing, MPPT limits, and 240 V interconnection.

### What breaker and wire size does Schneider Electric USA Inc: HY8K1NA1 {240V} require?

At 7,626 W continuous AC (240 V), continuous current is 31.8 A; 125% NEC 690.8/705.12 sizing requires a 40 A breaker and 8 AWG Cu (75 C) wire.

### Does Schneider Electric USA Inc: HY8K1NA1 {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 40 A at 240 V means PASS (120% Rule).

### How does Schneider Electric USA Inc: HY8K1NA1 {240V} compare to dcbel Inc: Dcbel Ara (DBHS-ARxx-xx) {240V}?

Schneider Electric USA Inc: HY8K1NA1 {240V} delivers 7,626 W AC at 97.16% CEC efficiency with a 480 V DC ceiling, while dcbel Inc: Dcbel Ara (DBHS-ARxx-xx) {240V} outputs 7,624 W at 240 V.

## Related Pages

Explore Schneider Electric USA Inc hardware, dcbel Inc: Dcbel Ara (DBHS-ARxx-xx) {240V}, utility rates, and NEC 705.12 sizing calculators alongside Schneider Electric USA Inc: HY8K1NA1 {240V}.

[All Schneider Electric USA Inc Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/schneider-electric-usa-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Schneider Electric USA Inc

- [All Schneider Electric USA Inc Specs](https://epri-peac.com/solar-equipment/brands/schneider-electric-usa-inc/)
- [Schneider Electric USA Inc: CS2200-NA {600V}](https://epri-peac.com/solar-equipment/inverters/schneider-electric-usa-inc/schneider-electric-usa-inc-cs2200-na-600v/)
- [Schneider Electric USA Inc: CS2000-NA {575V}](https://epri-peac.com/solar-equipment/inverters/schneider-electric-usa-inc/schneider-electric-usa-inc-cs2000-na-575v/)
- [Schneider Electric USA Inc: CS1800-NA {575V}](https://epri-peac.com/solar-equipment/inverters/schneider-electric-usa-inc/schneider-electric-usa-inc-cs1800-na-575v/)
- [Schneider Electric USA Inc: CS1666-1-NA {575V}](https://epri-peac.com/solar-equipment/inverters/schneider-electric-usa-inc/schneider-electric-usa-inc-cs1666-1-na-575v/)
- [Schneider Electric USA Inc: CS1666-2-NA {575V}](https://epri-peac.com/solar-equipment/inverters/schneider-electric-usa-inc/schneider-electric-usa-inc-cs1666-2-na-575v/)