CEC Grid-Support Inverter

# Savant Systems Inc: PS-INV-125KW-60A-XX {240V} — CEC Inverter Specifications

Manufacturer: [**Savant Systems Inc**](https://epri-peac.com/solar-equipment/brands/savant-systems-inc/) Registry: **CEC Verified Engineering Specification**

Savant Systems Inc: PS-INV-125KW-60A-XX {240V} outputs 12,411 W AC at 240 V (51.7 A continuous, 70 A OCPD), ranking #1,936 of 2,343 CEC inverters at 96.04% efficiency with a 250-530 V MPPT window and 530 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 12,411 W

- **AC Voltage** : 240 V

- **Min PV Breaker** : 70 A (4 AWG Cu)

- **CEC Efficiency** : 96.04%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Savant Systems Inc: PS-INV-125KW-60A-XX {240V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 240 V grid-support overview for Savant Systems Inc: PS-INV-125KW-60A-XX {240V}. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Rated at 12,411 W AC (51.7 A continuous), Savant Systems Inc: PS-INV-125KW-60A-XX {240V} ranks #1,936 of 2,343 CEC units at 96.04% efficiency (-0.64 pts vs the 96.68% 240 V median). Minimum 75 C copper conductor sizing for its 70 A circuit is 4 AWG Cu per NEC Table 310.16. Cold-weather string Voc must remain under 530 V DC at record local winter lows.

## Where Does Savant Systems Inc: PS-INV-125KW-60A-XX {240V} Fall Across Listed CEC Models?

Marks Savant Systems Inc: PS-INV-125KW-60A-XX {240V} (12,411 W AC) across the California Energy Commission inverter AC capacity distribution.

## What Dataset Percentiles Define Savant Systems Inc: PS-INV-125KW-60A-XX {240V}?

Benchmarks Savant Systems Inc: PS-INV-125KW-60A-XX {240V} continuous AC output, 96.04% CEC weighted efficiency, and 70 A OCPD breaker demand.

## What Do the Dataset Ranks Show for Savant Systems Inc: PS-INV-125KW-60A-XX {240V}?

Four key NEC 705.12 and California Energy Commission metrics defining Savant Systems Inc: PS-INV-125KW-60A-XX {240V} by Savant Systems Inc.

Eff #1,936 / 2,343

### 96.04% CEC Weighted Efficiency

-0.64 pts vs the 96.68% 240 V median; overall power rank #702 (12,411 W, top 30.0%; higher than 70.0% of peers).

NEC 705.12 Check

### 70 A Required Backfeed OCPD

125% x 51.7 A = 64.6 A -> 70 A standard OCPD using 4 AWG Cu (75 C).

MPPT Window

### 250 V - 530 V (Max 530 V DC)

Tracking span of 280.0 V; listed since 2023-01-11 (hybrid battery-capable inverter).

Panel Fit (240V)

### Needs Derate / Tap 705.11

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 12410.9W / 240 V -> 51.7 A | Breaker >= 1.25 * 51.7 = 64.6 A -> 70 A

CEC Inverters.csv for Savant Systems Inc: PS-INV-125KW-60A-XX {240V}: Paco=12410.9 W, Vac=240 V, Vdcmax=530.0 V, Eff=96.04%.

**Result:** Min 70 A breaker & 4 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.

## What Are the Published CEC Specifications for Savant Systems Inc: PS-INV-125KW-60A-XX {240V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for Savant Systems Inc: PS-INV-125KW-60A-XX {240V}.

Official California Energy Commission (NREL SAM) test parameters for Savant Systems Inc: PS-INV-125KW-60A-XX {240V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 12,411 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 530 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 250 V - 530 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 35.8982 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 96.04% | Calculated AC/DC conversion ratio from CEC test protocol |
| **CEC Listing Date & Hybrid** | 2023-01-11 / Hybrid: Yes (Battery Capable) | Utility interconnection approval metadata |

## Can a Residential Panel Meet 120% Busbar Limits for Savant Systems Inc: PS-INV-125KW-60A-XX {240V}?

Evaluates Savant Systems Inc: PS-INV-125KW-60A-XX {240V} (70 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates Savant Systems Inc: PS-INV-125KW-60A-XX {240V} (70 A required OCPD at 240 V) across standard distribution busbars.

| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **100A Bus / 100A Main** | 20 A | 70 A | Needs Derate / Tap 705.11 |
| **150A Bus / 150A Main** | 30 A | 70 A | Needs Derate / Tap 705.11 |
| **200A Bus / 200A Main** | 40 A | 70 A | Needs Derate / Tap 705.11 |
| **200A Bus / 175A Main** | 65 A | 70 A | Needs Derate / Tap 705.11 |
| **225A Bus / 200A Main** | 70 A | 70 A | PASS (120% Rule) |

## Which CEC PV Module Strings Pair With Savant Systems Inc: PS-INV-125KW-60A-XX {240V}?

Sample PV string lengths aligned within 250-530 V MPPT and 530 V DC max at -10 C. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Sampled CEC PV modules aligned within 250.0-530.0 V MPPT and 530.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 6 to 9 panels | 5.31 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 8 to 12 panels | 5.28 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 8 to 11 panels | 4.67 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 9 to 13 panels | 2.6 kW |

## Which Competing Grid-Support Inverters Compare to Savant Systems Inc: PS-INV-125KW-60A-XX {240V}?

Competing CEC grid-support inverters near 12,411 W AC and 240 V, led by Amensolar Ess Co Ltd: N3H-X12US {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Amensolar Ess Co Ltd: N3H-X12US {240V}**](https://epri-peac.com/solar-equipment/inverters/amensolar-ess-co-ltd/amensolar-ess-co-ltd-n3h-x12us-240v/) Amensolar Ess Co Ltd | 12,214 W | -197 W | 240.0 V | 430.0 V | 96.17% |
| [**Chint Power Systems America: CPS ECH12KTL/US {240V}**](https://epri-peac.com/solar-equipment/inverters/chint-power-systems-america/chint-power-systems-america-cps-ech12ktl-us-240v/) Chint Power Systems America | 11,990 W | -421 W | 240.0 V | 480.0 V | 96.59% |
| [**Delta Electronics: S12_BDI {240V}**](https://epri-peac.com/solar-equipment/inverters/delta-electronics/delta-electronics-s12-bdi-240v/) Delta Electronics | 11,589 W | -822 W | 240.0 V | 480.0 V | 96.99% |
| [**Base Power Inc: MIN 11400TL-XH-US {240V}**](https://epri-peac.com/solar-equipment/inverters/base-power-inc/base-power-inc-min-11400tl-xh-us-240v/) Base Power Inc | 11,520 W | -891 W | 240.0 V | 480.0 V | 97.76% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Savant Systems Inc: PS-INV-125KW-60A-XX {240V}?

Check Savant Systems Inc: PS-INV-125KW-60A-XX {240V} (12,411 W AC, 70 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Its 70 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 530 V DC on Savant Systems Inc: PS-INV-125KW-60A-XX {240V}.

### Savant Systems Inc: PS-INV-125KW-60A-XX {240V} Panel & Wire Spec

Size 75 C copper conductors at 4 AWG Cu on a 70 A OCPD breaker (51.7 A continuous).

### Alternative Inverter Comparison

Compare efficiency (96.04%) and MPPT window (250-530 V) directly against Amensolar Ess Co Ltd: N3H-X12US {240V} (12,214 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Savant Systems Inc: PS-INV-125KW-60A-XX {240V} by Savant Systems Inc covering breaker sizing, MPPT limits, and 240 V interconnection.

### What breaker and wire size does Savant Systems Inc: PS-INV-125KW-60A-XX {240V} require?

At 12,411 W continuous AC (240 V), continuous current is 51.7 A; 125% NEC 690.8/705.12 sizing requires a 70 A breaker and 4 AWG Cu (75 C) wire.

### Does Savant Systems Inc: PS-INV-125KW-60A-XX {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 70 A at 240 V means Needs Derate / Tap 705.11.

### How does Savant Systems Inc: PS-INV-125KW-60A-XX {240V} compare to Amensolar Ess Co Ltd: N3H-X12US {240V}?

Savant Systems Inc: PS-INV-125KW-60A-XX {240V} delivers 12,411 W AC at 96.04% CEC efficiency with a 530 V DC ceiling, while Amensolar Ess Co Ltd: N3H-X12US {240V} outputs 12,214 W at 240 V.

## Related Pages

Explore Savant Systems Inc hardware, Amensolar Ess Co Ltd: N3H-X12US {240V}, utility rates, and NEC 705.12 sizing calculators alongside Savant Systems Inc: PS-INV-125KW-60A-XX {240V}.

[All Savant Systems Inc Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/savant-systems-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Savant Systems Inc

- [All Savant Systems Inc Specs](https://epri-peac.com/solar-equipment/brands/savant-systems-inc/)
- [Savant Systems Inc: PS-INV-125KW-100A-XX {240V}](https://epri-peac.com/solar-equipment/inverters/savant-systems-inc/savant-systems-inc-ps-inv-125kw-100a-xx-240v/)
- [Savant Systems Inc: PS-INV-10KW-100A-XX {240V}](https://epri-peac.com/solar-equipment/inverters/savant-systems-inc/savant-systems-inc-ps-inv-10kw-100a-xx-240v/)
- [Savant Systems Inc: PS-INV-10KW-60A-XX {240V}](https://epri-peac.com/solar-equipment/inverters/savant-systems-inc/savant-systems-inc-ps-inv-10kw-60a-xx-240v/)