CEC Grid-Support Inverter

# RNG International Inc: RIV4850HI-SPS {240V} — CEC Inverter Specifications

Manufacturer: [**RNG International Inc**](https://epri-peac.com/solar-equipment/brands/rng-international-inc/) Registry: **CEC Verified Engineering Specification**

RNG International Inc: RIV4850HI-SPS {240V} outputs 5,090 W AC at 240 V (21.2 A continuous, 30 A OCPD), ranking #1,019 of 2,343 CEC inverters at 96.99% efficiency with a 180-430 V MPPT window and 430 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 5,090 W

- **AC Voltage** : 240 V

- **Min PV Breaker** : 30 A (10 AWG Cu)

- **CEC Efficiency** : 96.99%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does RNG International Inc: RIV4850HI-SPS {240V} Compare Against Peer CEC Listings?

CEC efficiency rank (#1,019), 180-430 V MPPT tracking, and panel fit for RNG International Inc: RIV4850HI-SPS {240V}. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

RNG International Inc: RIV4850HI-SPS {240V} from RNG International Inc outputs 21.2 A continuous AC at 240 V (5,090 W AC, rank #1,473). Paired with 10 AWG Cu conductors and a 30 A OCPD, its 96.99% CEC efficiency compares closely with Amensolar Ess Co Ltd: N3H-X50-US {240V} (5,090 W). Keep NEC 690.7 winter string Voc below 430 V DC.

## Where Does RNG International Inc: RIV4850HI-SPS {240V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting RNG International Inc: RIV4850HI-SPS {240V} at 5,090 W continuous AC output. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

## What Dataset Percentiles Define RNG International Inc: RIV4850HI-SPS {240V}?

Dataset percentiles comparing RNG International Inc: RIV4850HI-SPS {240V} against 2,343 certified grid-support inverters nationwide. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

## What Do the Dataset Ranks Show for RNG International Inc: RIV4850HI-SPS {240V}?

Engineering highlights for RNG International Inc: RIV4850HI-SPS {240V} covering efficiency, 10 AWG Cu feeder, and panel compatibility. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Eff #1,019 / 2,343

### 96.99% CEC Weighted Efficiency

+0.31 pts vs the 96.68% 240 V median; overall power rank #1,473 (5,090 W, below CEC median; higher than 37.0% of peers).

NEC 705.12 Check

### 30 A Required Backfeed OCPD

125% x 21.2 A = 26.5 A -> 30 A standard OCPD using 10 AWG Cu (75 C).

MPPT Window

### 180 V - 430 V (Max 430 V DC)

Tracking span of 250.0 V; listed since 2024-09-03 (hybrid battery-capable inverter).

Panel Fit (240V)

### PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 5089.7W / 240 V -> 21.2 A | Breaker >= 1.25 * 21.2 = 26.5 A -> 30 A

CEC Inverters.csv for RNG International Inc: RIV4850HI-SPS {240V}: Paco=5089.7 W, Vac=240 V, Vdcmax=430.0 V, Eff=96.99%.

**Result:** Min 30 A breaker & 10 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

## What Are the Published CEC Specifications for RNG International Inc: RIV4850HI-SPS {240V}?

California Energy Commission Solar Equipment List parameters for RNG International Inc: RIV4850HI-SPS {240V} (hybrid battery-capable inverter) interconnection. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Official California Energy Commission (NREL SAM) test parameters for RNG International Inc: RIV4850HI-SPS {240V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 5,090 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 430 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 180 V - 430 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 14.5766 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 96.99% | Calculated AC/DC conversion ratio from CEC test protocol |
| **CEC Listing Date & Hybrid** | 2024-09-03 / Hybrid: Yes (Battery Capable) | Utility interconnection approval metadata |

## Can a Residential Panel Meet 120% Busbar Limits for RNG International Inc: RIV4850HI-SPS {240V}?

Panelboard and switchgear backfeed allowances for RNG International Inc: RIV4850HI-SPS {240V} (30 A OCPD). Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Evaluates RNG International Inc: RIV4850HI-SPS {240V} (30 A required OCPD at 240 V) across standard distribution busbars.

| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **100A Bus / 100A Main** | 20 A | 30 A | Needs Derate / Tap 705.11 |
| **150A Bus / 150A Main** | 30 A | 30 A | PASS (120% Rule) |
| **200A Bus / 200A Main** | 40 A | 30 A | PASS (120% Rule) |
| **200A Bus / 175A Main** | 65 A | 30 A | PASS (120% Rule) |
| **225A Bus / 200A Main** | 70 A | 30 A | PASS (120% Rule) |

## Which CEC PV Module Strings Pair With RNG International Inc: RIV4850HI-SPS {240V}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for RNG International Inc: RIV4850HI-SPS {240V}. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sampled CEC PV modules aligned within 180.0-430.0 V MPPT and 430.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 5 to 7 panels | 4.13 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 6 to 10 panels | 4.4 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 6 to 9 panels | 3.83 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 7 to 10 panels | 2.0 kW |

## Which Competing Grid-Support Inverters Compare to RNG International Inc: RIV4850HI-SPS {240V}?

Four alternative CEC inverters matched to RNG International Inc: RIV4850HI-SPS {240V} (5,090 W AC), led by Amensolar Ess Co Ltd: N3H-X50-US {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Amensolar Ess Co Ltd: N3H-X50-US {240V}**](https://epri-peac.com/solar-equipment/inverters/amensolar-ess-co-ltd/amensolar-ess-co-ltd-n3h-x50-us-240v/) Amensolar Ess Co Ltd | 5,090 W | Tie (0 W) | 240.0 V | 430.0 V | 96.99% |
| [**Amensolar Ess Co Ltd: N3H-X5US {240V}**](https://epri-peac.com/solar-equipment/inverters/amensolar-ess-co-ltd/amensolar-ess-co-ltd-n3h-x5us-240v/) Amensolar Ess Co Ltd | 5,090 W | Tie (0 W) | 240.0 V | 430.0 V | 96.99% |
| [**Darfon Electronics Corp: H5000xxxxxx {240V}**](https://epri-peac.com/solar-equipment/inverters/darfon-electronics-corp/darfon-electronics-corp-h5000xxxxxx-240v/) Darfon Electronics Corp | 5,074 W | -16 W | 240.0 V | 380.0 V | 95.84% |
| [**Dyness Digital Energy Technology Co LTD: TX5K-HM {240V}**](https://epri-peac.com/solar-equipment/inverters/dyness-digital-energy-technology-co-ltd/dyness-digital-energy-technology-co-ltd-tx5k-hm-240v/) Dyness Digital Energy Technology Co LTD | 5,020 W | -70 W | 240.0 V | 500.0 V | 97.05% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for RNG International Inc: RIV4850HI-SPS {240V}?

Check RNG International Inc: RIV4850HI-SPS {240V} (5,090 W AC, 30 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Requires a 30 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 430 V DC on RNG International Inc: RIV4850HI-SPS {240V}.

### RNG International Inc: RIV4850HI-SPS {240V} Panel & Wire Spec

Size 75 C copper conductors at 10 AWG Cu on a 30 A OCPD breaker (21.2 A continuous).

### Alternative Inverter Comparison

Compare efficiency (96.99%) and MPPT window (180-430 V) directly against Amensolar Ess Co Ltd: N3H-X50-US {240V} (5,090 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for RNG International Inc: RIV4850HI-SPS {240V} by RNG International Inc covering breaker sizing, MPPT limits, and 240 V interconnection.

### What breaker and wire size does RNG International Inc: RIV4850HI-SPS {240V} require?

At 5,090 W continuous AC (240 V), continuous current is 21.2 A; 125% NEC 690.8/705.12 sizing requires a 30 A breaker and 10 AWG Cu (75 C) wire.

### Does RNG International Inc: RIV4850HI-SPS {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 30 A at 240 V means PASS (120% Rule).

### How does RNG International Inc: RIV4850HI-SPS {240V} compare to Amensolar Ess Co Ltd: N3H-X50-US {240V}?

RNG International Inc: RIV4850HI-SPS {240V} delivers 5,090 W AC at 96.99% CEC efficiency with a 430 V DC ceiling, while Amensolar Ess Co Ltd: N3H-X50-US {240V} outputs 5,090 W at 240 V.

## Related Pages

Explore RNG International Inc hardware, Amensolar Ess Co Ltd: N3H-X50-US {240V}, utility rates, and NEC 705.12 sizing calculators alongside RNG International Inc: RIV4850HI-SPS {240V}.

[All RNG International Inc Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/rng-international-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From RNG International Inc

- [All RNG International Inc Specs](https://epri-peac.com/solar-equipment/brands/rng-international-inc/)
- [RNG International Inc: RIV4810HI-SPS {240V}](https://epri-peac.com/solar-equipment/inverters/rng-international-inc/rng-international-inc-riv4810hi-sps-240v/)
- [RNG International Inc: RIV4880HI-SPS {240V}](https://epri-peac.com/solar-equipment/inverters/rng-international-inc/rng-international-inc-riv4880hi-sps-240v/)
- [RNG International Inc: RIV4876HI-SPS {240V}](https://epri-peac.com/solar-equipment/inverters/rng-international-inc/rng-international-inc-riv4876hi-sps-240v/)
- [RNG International Inc: RIV4860HI-SPS {240V}](https://epri-peac.com/solar-equipment/inverters/rng-international-inc/rng-international-inc-riv4860hi-sps-240v/)