---
title: "Princeton Power Systems Inc Inverter (124,964W)"
url: https://epri-peac.com/solar-equipment/inverters/princeton-power-systems-inc/princeton-power-systems-inc-gtib-480-125xxxxxx-g15-480v/
description: "CEC specs for Princeton Power Systems Inc: GTIB-480-125XXXXXX-G15 {480V}: 124,964W AC, 480V, 200A OCPD, and NEC 705.12 checks."
---

CEC Grid-Support Inverter

# Princeton Power Systems Inc: GTIB-480-125XXXXXX-G15 {480V} — CEC Inverter Specifications

Manufacturer: [**Princeton Power Systems Inc**](https://epri-peac.com/solar-equipment/brands/princeton-power-systems-inc/) Registry: **CEC Verified Engineering Specification**

Princeton Power Systems Inc: GTIB-480-125XXXXXX-G15 {480V} outputs 124,964 W AC at 480 V, 3-phase (150.3 A continuous, 200 A OCPD), ranking #1,508 of 2,343 CEC inverters at 96.53% efficiency with a 350-830 V MPPT window and 830 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 124,964 W

- **AC Voltage** : 480 V, 3-phase

- **Min PV Breaker** : 200 A (3/0 AWG Cu)

- **CEC Efficiency** : 96.53%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Princeton Power Systems Inc: GTIB-480-125XXXXXX-G15 {480V} Compare Against Peer CEC Listings?

Breaker sizing (200 A), 3/0 AWG Cu wire rules, and DC input limits for Princeton Power Systems Inc: GTIB-480-125XXXXXX-G15 {480V}.

For NEC 705.12 solar interconnection, Princeton Power Systems Inc: GTIB-480-125XXXXXX-G15 {480V} outputs 150.3 A continuous AC at 480 V, 3-phase and needs a 200 A backfeed breaker on 3/0 AWG Cu (75 C). Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap. Conversion efficiency scores 96.53% (#1,508 of 2,343, -0.29 pts vs overall CEC median).

## Where Does Princeton Power Systems Inc: GTIB-480-125XXXXXX-G15 {480V} Fall Across Listed CEC Models?

Output power comparison showing where Princeton Power Systems Inc: GTIB-480-125XXXXXX-G15 {480V} sits among all 2,343 CEC-listed grid-support inverters.

## What Dataset Percentiles Define Princeton Power Systems Inc: GTIB-480-125XXXXXX-G15 {480V}?

Relative ranking of Princeton Power Systems Inc: GTIB-480-125XXXXXX-G15 {480V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

## What Do the Dataset Ranks Show for Princeton Power Systems Inc: GTIB-480-125XXXXXX-G15 {480V}?

Snapshot of Princeton Power Systems Inc: GTIB-480-125XXXXXX-G15 {480V} efficiency rank (#1,508), OCPD breaker size, MPPT span, and busbar verdict.

Eff #1,508 / 2,343

### 96.53% CEC Weighted Efficiency

-1.49 pts vs the 98.02% 480 V median; overall power rank #317 (124,964 W, top 13.6%; higher than 86.4% of peers).

NEC 705.12 Check

### 200 A Required Backfeed OCPD

125% x 150.3 A = 187.9 A -> 200 A standard OCPD using 3/0 AWG Cu (75 C).

MPPT Window

### 350 V - 830 V (Max 830 V DC)

Tracking span of 480.0 V; active in CEC directory (hybrid battery-capable inverter).

Commercial / 3-Phase Fit

### Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 480 V, 3-phase switchgear (200A Bus / 200A Main (480V) to 1,200A Bus / 1,200A Main (480V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 124964.0W / 480 V 3-phase -> 150.3 A | Breaker >= 1.25 * 150.3 = 187.9 A -> 200 A

CEC Inverters.csv for Princeton Power Systems Inc: GTIB-480-125XXXXXX-G15 {480V}: Paco=124964.0 W, Vac=480 V, Vdcmax=830.0 V, Eff=96.53%.

**Result:** Min 200 A breaker & 3/0 AWG Cu (75 C); 1,200A Bus / 1,200A Main (480V): PASS (120% Commercial Busbar).

## What Are the Published CEC Specifications for Princeton Power Systems Inc: GTIB-480-125XXXXXX-G15 {480V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Princeton Power Systems Inc: GTIB-480-125XXXXXX-G15 {480V}.

Official California Energy Commission (NREL SAM) test parameters for Princeton Power Systems Inc: GTIB-480-125XXXXXX-G15 {480V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 124,964 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 480 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 830 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 350 V - 830 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 182.329 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 96.53% | Calculated AC/DC conversion ratio from CEC test protocol |
| **Inverter Topology** | Hybrid: Yes (Battery Capable) | CEC Solar Equipment List grid-support certification |

## What Switchgear Limits Apply to Princeton Power Systems Inc: GTIB-480-125XXXXXX-G15 {480V} (480 V, 3-phase)?

NEC 705.12(B)(3)(2) backfeed compliance table for Princeton Power Systems Inc: GTIB-480-125XXXXXX-G15 {480V} at 480 V, 3-phase.

Evaluates Princeton Power Systems Inc: GTIB-480-125XXXXXX-G15 {480V} (200 A required OCPD at 480 V, 3-phase) across standard distribution busbars.

| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **200A Bus / 200A Main (480V)** | 40 A | 200 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **400A Bus / 400A Main (480V)** | 80 A | 200 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **600A Bus / 600A Main (480V)** | 120 A | 200 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **800A Bus / 800A Main (480V)** | 160 A | 200 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **1,200A Bus / 1,200A Main (480V)** | 240 A | 200 A | PASS (120% Commercial Busbar) |

## Which CEC PV Module Strings Pair With Princeton Power Systems Inc: GTIB-480-125XXXXXX-G15 {480V}?

Minimum and maximum series solar module strings fitting Princeton Power Systems Inc: GTIB-480-125XXXXXX-G15 {480V} MPPT and 830 V limits.

Sampled CEC PV modules aligned within 350.0-830.0 V MPPT and 830.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 9 to 14 panels | 8.26 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 11 to 19 panels | 8.36 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 11 to 18 panels | 7.65 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 13 to 20 panels | 4.0 kW |

## Which Competing Grid-Support Inverters Compare to Princeton Power Systems Inc: GTIB-480-125XXXXXX-G15 {480V}?

Peer 480 V, 3-phase CEC inverters near 124,964 W AC output such as Ginlong Technologies Co Ltd: S5-GC125K-US {480V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Ginlong Technologies Co Ltd: S5-GC125K-US {480V}**](https://epri-peac.com/solar-equipment/inverters/ginlong-technologies-co-ltd/ginlong-technologies-co-ltd-s5-gc125k-us-480v/) Ginlong Technologies Co Ltd | 124,991 W | +27 W | 480.0 V | 850.0 V | 97.88% |
| [**Chint Power Systems America: CPS ECB125KTL-M/US-480 {480V}**](https://epri-peac.com/solar-equipment/inverters/chint-power-systems-america/chint-power-systems-america-cps-ecb125ktl-m-us-480-480v/) Chint Power Systems America | 125,000 W | +36 W | 480.0 V | 1100.0 V | 97.2% |
| [**Delta Electronics: DES10JB125K01 {480V}**](https://epri-peac.com/solar-equipment/inverters/delta-electronics/delta-electronics-des10jb125k01-480v/) Delta Electronics | 125,000 W | +36 W | 480.0 V | 1000.0 V | 97.01% |
| [**Delta Electronics: PCS125 {480V}**](https://epri-peac.com/solar-equipment/inverters/delta-electronics/delta-electronics-pcs125-480v/) Delta Electronics | 125,000 W | +36 W | 480.0 V | 1000.0 V | 97.01% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Princeton Power Systems Inc: GTIB-480-125XXXXXX-G15 {480V}?

Check Princeton Power Systems Inc: GTIB-480-125XXXXXX-G15 {480V} (124,964 W AC, 200 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 830 V DC on Princeton Power Systems Inc: GTIB-480-125XXXXXX-G15 {480V}.

### Princeton Power Systems Inc: GTIB-480-125XXXXXX-G15 {480V} Panel & Wire Spec

Size 75 C copper conductors at 3/0 AWG Cu on a 200 A OCPD breaker (150.3 A continuous).

### Alternative Inverter Comparison

Compare efficiency (96.53%) and MPPT window (350-830 V) directly against Ginlong Technologies Co Ltd: S5-GC125K-US {480V} (124,991 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Princeton Power Systems Inc: GTIB-480-125XXXXXX-G15 {480V} by Princeton Power Systems Inc covering breaker sizing, MPPT limits, and 480 V, 3-phase interconnection.

### What breaker and wire size does Princeton Power Systems Inc: GTIB-480-125XXXXXX-G15 {480V} require?

At 124,964 W continuous AC (480 V, 3-phase), continuous current is 150.3 A; 125% NEC 690.8/705.12 sizing requires a 200 A breaker and 3/0 AWG Cu (75 C) wire.

### What commercial switchgear or feeder sizing does Princeton Power Systems Inc: GTIB-480-125XXXXXX-G15 {480V} require?

At 124,964 W AC and 480 V, 3-phase, continuous line current is 150.3 A, requiring a 200 A OCPD and 1,200A Bus / 1,200A Main (480V) or NEC 705.11 interconnection.

### How does Princeton Power Systems Inc: GTIB-480-125XXXXXX-G15 {480V} compare to Ginlong Technologies Co Ltd: S5-GC125K-US {480V}?

Princeton Power Systems Inc: GTIB-480-125XXXXXX-G15 {480V} delivers 124,964 W AC at 96.53% CEC efficiency with a 830 V DC ceiling, while Ginlong Technologies Co Ltd: S5-GC125K-US {480V} outputs 124,991 W at 480 V, 3-phase.

## Related Pages

Explore Princeton Power Systems Inc hardware, Ginlong Technologies Co Ltd: S5-GC125K-US {480V}, utility rates, and NEC 705.12 sizing calculators alongside Princeton Power Systems Inc: GTIB-480-125XXXXXX-G15 {480V}.

[All Princeton Power Systems Inc Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/princeton-power-systems-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Princeton Power Systems Inc

- [All Princeton Power Systems Inc Specs](https://epri-peac.com/solar-equipment/brands/princeton-power-systems-inc/)
- [Princeton Power Systems Inc: GTIB-480-125XXXXXX-W-G15 {480V}](https://epri-peac.com/solar-equipment/inverters/princeton-power-systems-inc/princeton-power-systems-inc-gtib-480-125xxxxxx-w-g15-480v/)
- [Princeton Power Systems Inc: GTIB-480-30-ZZZZZZ-G13 {480V}](https://epri-peac.com/solar-equipment/inverters/princeton-power-systems-inc/princeton-power-systems-inc-gtib-480-30-zzzzzz-g13-480v/)
- [Princeton Power Systems Inc: GTIB-480-30-WZZZZZZ-G13 {480V}](https://epri-peac.com/solar-equipment/inverters/princeton-power-systems-inc/princeton-power-systems-inc-gtib-480-30-wzzzzzz-g13-480v/)
