---
title: "Power Electronics: FS4200M Inverter (4,198,715W)"
url: https://epri-peac.com/solar-equipment/inverters/power-electronics/power-electronics-fs4200m-34500v/
description: "CEC specs for Power Electronics: FS4200M {34500V}: 4,198,715W AC, 34500V, 90A OCPD, and NEC 705.12 checks. Verified US government and CEC engineering data."
---

CEC Grid-Support Inverter

# Power Electronics: FS4200M {34500V} — CEC Inverter Specifications

Manufacturer: [**Power Electronics**](https://epri-peac.com/solar-equipment/brands/power-electronics/) Registry: **CEC Verified Engineering Specification**

Power Electronics: FS4200M {34500V} outputs 4,198,715 W AC at 34,500 V, 3-phase (70.3 A continuous, 90 A OCPD), ranking #376 of 2,343 CEC inverters at 97.92% efficiency with a 934-1,200 V MPPT window and 1,200 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 4,198,715 W

- **AC Voltage** : 34,500 V, 3-phase

- **Min PV Breaker** : 90 A (3 AWG Cu)

- **CEC Efficiency** : 97.92%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Power Electronics: FS4200M {34500V} Compare Against Peer CEC Listings?

How Power Electronics Power Electronics: FS4200M {34500V} compares on 97.92% efficiency, MPPT span, and 120% busbar interconnection. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

With a 934-1,200 V MPPT tracking band and 1,200 V DC ceiling, Power Electronics: FS4200M {34500V} handles 4,198,715 W continuous AC (861,062 W above the 3,337,653 W 34,500 V median). Commercial 34,500 V, 3-phase switchgear interconnection uses 5.0 MVA Utility Substation or NEC 705.11 supply-side tap. Installers comparing Power Electronics against Sungrow Power Supply Co Ltd: SG3150U {630V} (3,154,300 W) should verify whether active in CEC directory grid-support firmware meets local IEEE 1547 utility rules.

## Where Does Power Electronics: FS4200M {34500V} Fall Across Listed CEC Models?

Position of Power Electronics: FS4200M {34500V} (4,198,715 W AC) relative to the 7,680 W CEC median inverter. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

## What Dataset Percentiles Define Power Electronics: FS4200M {34500V}?

Percentile placement of Power Electronics: FS4200M {34500V} across AC power class, conversion efficiency, and backfeed breaker size. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

## What Do the Dataset Ranks Show for Power Electronics: FS4200M {34500V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for Power Electronics: FS4200M {34500V}. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Eff #376 / 2,343

### 97.92% CEC Weighted Efficiency

+0.51 pts vs the 97.41% 34,500 V median; overall power rank #6 (4,198,715 W, top 0.3%; higher than 99.7% of peers).

NEC 705.12 Check

### 90 A Required Backfeed OCPD

125% x 70.3 A = 87.9 A -> 90 A standard OCPD using 3 AWG Cu (75 C).

MPPT Window

### 934 V - 1,200 V (Max 1,200 V DC)

Tracking span of 266.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

### Medium-Voltage Utility Skid (NEC 705.11 / IEEE 1547)

Evaluated for 34,500 V, 3-phase switchgear (1.0 MVA MV Step-Up to 5.0 MVA Utility Substation) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 4198715.0W / 34,500 V 3-phase -> 70.3 A | Breaker >= 1.25 * 70.3 = 87.9 A -> 90 A

CEC Inverters.csv for Power Electronics: FS4200M {34500V}: Paco=4198715.0 W, Vac=34500 V, Vdcmax=1200.0 V, Eff=97.92%.

**Result:** Min 90 A breaker & 3 AWG Cu (75 C); 5.0 MVA Utility Substation: Medium-Voltage Utility Skid (NEC 705.11 / IEEE 1547).

## What Are the Published CEC Specifications for Power Electronics: FS4200M {34500V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for Power Electronics: FS4200M {34500V}. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Official California Energy Commission (NREL SAM) test parameters for Power Electronics: FS4200M {34500V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 4,198,715 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 34,500 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 1,200 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 934 V - 1,200 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 4018.61 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 97.92% | Calculated AC/DC conversion ratio from CEC test protocol |
| **Inverter Topology** | Hybrid: No (Grid-Tied PV) | CEC Solar Equipment List grid-support certification |

## What Switchgear Limits Apply to Power Electronics: FS4200M {34500V} (34,500 V, 3-phase)?

Check whether Power Electronics: FS4200M {34500V} (90 A breaker) fits without main breaker derate or supply-side taps. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Evaluates Power Electronics: FS4200M {34500V} (90 A required OCPD at 34,500 V, 3-phase) across standard distribution busbars.

| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **1.0 MVA MV Step-Up** | Utility MV Interconnect | 90 A @ 34,500V | Medium-Voltage Utility Skid (NEC 705.11 / IEEE 1547) |
| **2.5 MVA MV Step-Up** | Utility MV Interconnect | 90 A @ 34,500V | Medium-Voltage Utility Skid (NEC 705.11 / IEEE 1547) |
| **5.0 MVA Utility Substation** | Utility MV Interconnect | 90 A @ 34,500V | Medium-Voltage Utility Skid (NEC 705.11 / IEEE 1547) |

## Which CEC PV Module Strings Pair With Power Electronics: FS4200M {34500V}?

Verified cold-weather (-10 C) series module counts matched to Power Electronics: FS4200M {34500V}'s 1,200 V DC ceiling.

Sampled CEC PV modules aligned within 934.0-1200.0 V MPPT and 1200.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 28 panels (fixed) | 12.32 kW |

## Which Competing Grid-Support Inverters Compare to Power Electronics: FS4200M {34500V}?

Alternative CEC inverters comparable to Power Electronics: FS4200M {34500V}, including Sungrow Power Supply Co Ltd: SG3150U {630V} (3,154,300 W) at 34,500 V, 3-phase.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Sungrow Power Supply Co Ltd: SG3150U {630V}**](https://epri-peac.com/solar-equipment/inverters/sungrow-power-supply-co-ltd/sungrow-power-supply-co-ltd-sg3150u-630v/) Sungrow Power Supply Co Ltd | 3,154,300 W | -1044415 W | 630.0 V | 1300.0 V | 97.49% |
| [**INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C480 {480V}**](https://epri-peac.com/solar-equipment/inverters/ingeteam-power-technology-sa/ingeteam-power-technology-sa-ingecon-sun-storage-3660tl-u-c480-480v/) INGETEAM POWER TECHNOLOGY SA | 2,467,620 W | -1731095 W | 480.0 V | 1300.0 V | 96.63% |
| [**SINENG ELECTRIC CO LTD: EH-1725-HA-UD-US {690V}**](https://epri-peac.com/solar-equipment/inverters/sineng-electric-co-ltd/sineng-electric-co-ltd-eh-1725-ha-ud-us-690v/) SINENG ELECTRIC CO LTD | 1,726,700 W | -2472015 W | 690.0 V | 1500.0 V | 98.32% |
| [**Schneider Electric USA Inc: CS1666-3-NA {575V}**](https://epri-peac.com/solar-equipment/inverters/schneider-electric-usa-inc/schneider-electric-usa-inc-cs1666-3-na-575v/) Schneider Electric USA Inc | 1,666,000 W | -2532715 W | 575.0 V | 1200.0 V | 97.54% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Power Electronics: FS4200M {34500V}?

Check Power Electronics: FS4200M {34500V} (4,198,715 W AC, 90 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 34,500 V, 3-phase switchgear interconnection uses 5.0 MVA Utility Substation or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,200 V DC on Power Electronics: FS4200M {34500V}.

### Power Electronics: FS4200M {34500V} Panel & Wire Spec

Size 75 C copper conductors at 3 AWG Cu on a 90 A OCPD breaker (70.3 A continuous).

### Alternative Inverter Comparison

Compare efficiency (97.92%) and MPPT window (934-1,200 V) directly against Sungrow Power Supply Co Ltd: SG3150U {630V} (3,154,300 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Power Electronics: FS4200M {34500V} by Power Electronics covering breaker sizing, MPPT limits, and 34,500 V, 3-phase interconnection.

### What breaker and wire size does Power Electronics: FS4200M {34500V} require?

At 4,198,715 W continuous AC (34,500 V, 3-phase), continuous current is 70.3 A; 125% NEC 690.8/705.12 sizing requires a 90 A breaker and 3 AWG Cu (75 C) wire.

### What commercial switchgear or feeder sizing does Power Electronics: FS4200M {34500V} require?

At 4,198,715 W AC and 34,500 V, 3-phase, continuous line current is 70.3 A, requiring a 90 A OCPD and 5.0 MVA Utility Substation or NEC 705.11 interconnection.

### How does Power Electronics: FS4200M {34500V} compare to Sungrow Power Supply Co Ltd: SG3150U {630V}?

Power Electronics: FS4200M {34500V} delivers 4,198,715 W AC at 97.92% CEC efficiency with a 1,200 V DC ceiling, while Sungrow Power Supply Co Ltd: SG3150U {630V} outputs 3,154,300 W at 34,500 V, 3-phase.

## Related Pages

Explore Power Electronics hardware, Sungrow Power Supply Co Ltd: SG3150U {630V}, utility rates, and NEC 705.12 sizing calculators alongside Power Electronics: FS4200M {34500V}.

[All Power Electronics Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/power-electronics/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Power Electronics

- [All Power Electronics Specs](https://epri-peac.com/solar-equipment/brands/power-electronics/)
- [Power Electronics: FP4200M {34500V}](https://epri-peac.com/solar-equipment/inverters/power-electronics/power-electronics-fp4200m-34500v/)
- [Power Electronics: FS4010K {630V}](https://epri-peac.com/solar-equipment/inverters/power-electronics/power-electronics-fs4010k-630v/)
- [POWER ELECTRONICS: FS3820K {600V}](https://epri-peac.com/solar-equipment/inverters/power-electronics/power-electronics-fs3820k-600v/)
- [Power Electronics: FP3510M2 {34500V}](https://epri-peac.com/solar-equipment/inverters/power-electronics/power-electronics-fp3510m2-34500v/)
- [Power Electronics: FP3510M3 {34500V}](https://epri-peac.com/solar-equipment/inverters/power-electronics/power-electronics-fp3510m3-34500v/)
