title: "Power Center: D350-M1A-240A {240V} Inverter (346W)"
url: https://epri-peac.com/solar-equipment/inverters/power-center/power-center-d350-m1a-240a-240v/
description: "CEC specs for Power Center: D350-M1A-240A {240V}: 346W AC, 240V, 15A OCPD, and NEC 705.12 checks. Verified US government and CEC engineering data."
---

CEC Grid-Support Inverter

# Power Center: D350-M1A-240A {240V} — CEC Inverter Specifications

Manufacturer: [**Power Center**](https://epri-peac.com/solar-equipment/brands/power-center/) Registry: **CEC Verified Engineering Specification**

Power Center: D350-M1A-240A {240V} outputs 346 W AC at 240 V (1.4 A continuous, 15 A OCPD), ranking #1,776 of 2,343 CEC inverters at 96.29% efficiency with a 22-55 V MPPT window and 55 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 346 W

- **AC Voltage** : 240 V

- **Min PV Breaker** : 15 A (14 AWG Cu)

- **CEC Efficiency** : 96.29%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Power Center: D350-M1A-240A {240V} Compare Against Peer CEC Listings?

How Power Center Power Center: D350-M1A-240A {240V} compares on 96.29% efficiency, MPPT span, and 120% busbar interconnection. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

With a 22-55 V MPPT tracking band and 55 V DC ceiling, Power Center: D350-M1A-240A {240V} handles 346 W continuous AC (5,430 W below the 5,776 W 240 V median). Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit. Installers comparing Power Center against Aptos Solar Technology LLC: MAC-400 {240V} (382 W) should verify whether active in CEC directory grid-support firmware meets local IEEE 1547 utility rules.

## Where Does Power Center: D350-M1A-240A {240V} Fall Across Listed CEC Models?

Position of Power Center: D350-M1A-240A {240V} (346 W AC) relative to the 7,680 W CEC median inverter. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

## What Dataset Percentiles Define Power Center: D350-M1A-240A {240V}?

Percentile placement of Power Center: D350-M1A-240A {240V} across AC power class, conversion efficiency, and backfeed breaker size. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

## What Do the Dataset Ranks Show for Power Center: D350-M1A-240A {240V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for Power Center: D350-M1A-240A {240V}. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Eff #1,776 / 2,343

### 96.29% CEC Weighted Efficiency

-0.39 pts vs the 96.68% 240 V median; overall power rank #2,117 (346 W, below CEC median; higher than 9.6% of peers).

NEC 705.12 Check

### 15 A Required Backfeed OCPD

125% x 1.4 A = 1.8 A -> 15 A standard OCPD using 14 AWG Cu (75 C).

MPPT Window

### 22 V - 55 V (Max 55 V DC)

Tracking span of 33.0 V; active in CEC directory (grid-tied PV inverter).

Panel Fit (240V)

### PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 346.0W / 240 V -> 1.4 A | Breaker >= 1.25 * 1.4 = 1.8 A -> 15 A

CEC Inverters.csv for Power Center: D350-M1A-240A {240V}: Paco=346.0 W, Vac=240 V, Vdcmax=55.0 V, Eff=96.29%.

**Result:** Min 15 A breaker & 14 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

## What Are the Published CEC Specifications for Power Center: D350-M1A-240A {240V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for Power Center: D350-M1A-240A {240V}. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Official California Energy Commission (NREL SAM) test parameters for Power Center: D350-M1A-240A {240V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 346 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 55 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 22 V - 55 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 10.2666 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 96.29% | Calculated AC/DC conversion ratio from CEC test protocol |
| **Inverter Topology** | Hybrid: No (Grid-Tied PV) | CEC Solar Equipment List grid-support certification |

## Can a Residential Panel Meet 120% Busbar Limits for Power Center: D350-M1A-240A {240V}?

Check whether Power Center: D350-M1A-240A {240V} (15 A breaker) fits without main breaker derate or supply-side taps. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Evaluates Power Center: D350-M1A-240A {240V} (15 A required OCPD at 240 V) across standard distribution busbars.

| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **100A Bus / 100A Main** | 20 A | 15 A | PASS (120% Rule) |
| **150A Bus / 150A Main** | 30 A | 15 A | PASS (120% Rule) |
| **200A Bus / 200A Main** | 40 A | 15 A | PASS (120% Rule) |
| **200A Bus / 175A Main** | 65 A | 15 A | PASS (120% Rule) |
| **225A Bus / 200A Main** | 70 A | 15 A | PASS (120% Rule) |

## Which CEC PV Module Strings Pair With Power Center: D350-M1A-240A {240V}?

Verified cold-weather (-10 C) series module counts matched to Power Center: D350-M1A-240A {240V}'s 55 V DC ceiling.

Sampled CEC PV modules aligned within 22.0-55.0 V MPPT and 55.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 1 panel (micro/module) | 0.44 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 1 panel (micro/module) | 0.42 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 1 panel (micro/module) | 0.2 kW |
| [**Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-515**](https://epri-peac.com/solar-equipment/modules/chint-new-energy-technology-co-ltd/chint-new-energy-technology-co-ltd-chsm72m-dg-f-bh-515/) | 515.0 W | 53.76 V | 1 panel (micro/module) | 0.52 kW |

## Which Competing Grid-Support Inverters Compare to Power Center: D350-M1A-240A {240V}?

Alternative CEC inverters comparable to Power Center: D350-M1A-240A {240V}, including Aptos Solar Technology LLC: MAC-400 {240V} (382 W) at 240 V.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Aptos Solar Technology LLC: MAC-400 {240V}**](https://epri-peac.com/solar-equipment/inverters/aptos-solar-technology-llc/aptos-solar-technology-llc-mac-400-240v/) Aptos Solar Technology LLC | 382 W | +36 W | 240.0 V | 48.0 V | 96.52% |
| [**Aptos Solar Technology LLC: MAC-400R {240V}**](https://epri-peac.com/solar-equipment/inverters/aptos-solar-technology-llc/aptos-solar-technology-llc-mac-400r-240v/) Aptos Solar Technology LLC | 382 W | +36 W | 240.0 V | 48.0 V | 96.52% |
| [**Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V}**](https://epri-peac.com/solar-equipment/inverters/chilicon-power-llc/chilicon-power-llc-cp-250e-60-72-208-240-mc4-240v/) Chilicon Power LLC | 289 W | -57 W | 240.0 V | 32.0 V | 95.41% |
| [**Altenergy Power System Inc: YC600 {240V}**](https://epri-peac.com/solar-equipment/inverters/altenergy-power-system-inc/altenergy-power-system-inc-yc600-240v/) Altenergy Power System Inc | 550 W | +204 W | 240.0 V | 45.0 V | 96.51% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Power Center: D350-M1A-240A {240V}?

Check Power Center: D350-M1A-240A {240V} (346 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 55 V DC on Power Center: D350-M1A-240A {240V}.

### Power Center: D350-M1A-240A {240V} Panel & Wire Spec

Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (1.4 A continuous).

### Alternative Inverter Comparison

Compare efficiency (96.29%) and MPPT window (22-55 V) directly against Aptos Solar Technology LLC: MAC-400 {240V} (382 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Power Center: D350-M1A-240A {240V} by Power Center covering breaker sizing, MPPT limits, and 240 V interconnection.

### What breaker and wire size does Power Center: D350-M1A-240A {240V} require?

At 346 W continuous AC (240 V), continuous current is 1.4 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.

### Does Power Center: D350-M1A-240A {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 15 A at 240 V means PASS (120% Rule).

### How does Power Center: D350-M1A-240A {240V} compare to Aptos Solar Technology LLC: MAC-400 {240V}?

Power Center: D350-M1A-240A {240V} delivers 346 W AC at 96.29% CEC efficiency with a 55 V DC ceiling, while Aptos Solar Technology LLC: MAC-400 {240V} outputs 382 W at 240 V.

## Related Pages

Explore Power Center hardware, Aptos Solar Technology LLC: MAC-400 {240V}, utility rates, and NEC 705.12 sizing calculators alongside Power Center: D350-M1A-240A {240V}.

[All Power Center Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/power-center/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Power Center

- [All Power Center Specs](https://epri-peac.com/solar-equipment/brands/power-center/)
- [Power Center: Max Hybrid 60 {277V}](https://epri-peac.com/solar-equipment/inverters/power-center/power-center-max-hybrid-60-277v/)
- [Power Center: Max Hybrid 30 (208V) {120V}](https://epri-peac.com/solar-equipment/inverters/power-center/power-center-max-hybrid-30-208v-120v/)
- [Power Center: Max Hybrid 15 {240V}](https://epri-peac.com/solar-equipment/inverters/power-center/power-center-max-hybrid-15-240v/)
- [Power Center: Max Hybrid 15 {208V}](https://epri-peac.com/solar-equipment/inverters/power-center/power-center-max-hybrid-15-208v/)
- [Power Center: Essential Hybrid 5 {240V}](https://epri-peac.com/solar-equipment/inverters/power-center/power-center-essential-hybrid-5-240v/)