CEC Grid-Support Inverter

# Pika Energy: X11402 {208V} — CEC Inverter Specifications

Manufacturer: [**Pika Energy**](https://epri-peac.com/solar-equipment/brands/pika-energy/) Registry: **CEC Verified Engineering Specification**

Pika Energy: X11402 {208V} outputs 11,187 W AC at 208 V, commercial single-phase (53.8 A continuous, 70 A OCPD), ranking #1,019 of 2,343 CEC inverters at 96.99% efficiency with a 390-420 V MPPT window and 420 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 11,187 W

- **AC Voltage** : 208 V, commercial single-phase

- **Min PV Breaker** : 70 A (4 AWG Cu)

- **CEC Efficiency** : 96.99%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Pika Energy: X11402 {208V} Compare Against Peer CEC Listings?

Breaker sizing (70 A), 4 AWG Cu wire rules, and DC input limits for Pika Energy: X11402 {208V}.

Classified as a hybrid battery-capable inverter (active in CEC directory), Pika Energy: X11402 {208V} requires 67.2 A design capacity -> 70 A breaker using 4 AWG Cu copper at 75 C terminals. Weighted efficiency sits at 96.99% (+0.17 pts vs overall CEC median) across 2,343 CEC models, while commercial 208 v, commercial single-phase switchgear interconnection uses 1,200a bus / 1,200a main (208v) or nec 705.11 supply-side tap.

## Where Does Pika Energy: X11402 {208V} Fall Across Listed CEC Models?

Output power comparison showing where Pika Energy: X11402 {208V} sits among all 2,343 CEC-listed grid-support inverters. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

## What Dataset Percentiles Define Pika Energy: X11402 {208V}?

Relative ranking of Pika Energy: X11402 {208V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

## What Do the Dataset Ranks Show for Pika Energy: X11402 {208V}?

Snapshot of Pika Energy: X11402 {208V} efficiency rank (#1,019), OCPD breaker size, MPPT span, and busbar verdict. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Eff #1,019 / 2,343

### 96.99% CEC Weighted Efficiency

+0.58 pts vs the 96.41% 208 V median; overall power rank #810 (11,187 W, top 34.6%; higher than 65.4% of peers).

NEC 705.12 Check

### 70 A Required Backfeed OCPD

125% x 53.8 A = 67.2 A -> 70 A standard OCPD using 4 AWG Cu (75 C).

MPPT Window

### 390 V - 420 V (Max 420 V DC)

Tracking span of 30.0 V; active in CEC directory (hybrid battery-capable inverter).

Commercial / 3-Phase Fit

### PASS (120% Commercial Busbar)

Evaluated for 208 V, commercial single-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 11187.0W / 208 V -> 53.8 A | Breaker >= 1.25 * 53.8 = 67.2 A -> 70 A

CEC Inverters.csv for Pika Energy: X11402 {208V}: Paco=11187.0 W, Vac=208 V, Vdcmax=420.0 V, Eff=96.99%.

**Result:** Min 70 A breaker & 4 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).

## What Are the Published CEC Specifications for Pika Energy: X11402 {208V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Pika Energy: X11402 {208V}. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Official California Energy Commission (NREL SAM) test parameters for Pika Energy: X11402 {208V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 11,187 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 208 V, commercial single-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 420 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 390 V - 420 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 28.8353 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 96.99% | Calculated AC/DC conversion ratio from CEC test protocol |
| **Inverter Topology** | Hybrid: Yes (Battery Capable) | CEC Solar Equipment List grid-support certification |

## What Switchgear Limits Apply to Pika Energy: X11402 {208V} (208 V, commercial single-phase)?

NEC 705.12(B)(3)(2) backfeed compliance table for Pika Energy: X11402 {208V} at 208 V, commercial single-phase.

Evaluates Pika Energy: X11402 {208V} (70 A required OCPD at 208 V, commercial single-phase) across standard distribution busbars.

| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **200A Bus / 200A Main (208V)** | 40 A | 70 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **400A Bus / 400A Main (208V)** | 80 A | 70 A | PASS (120% Commercial Busbar) |
| **600A Bus / 600A Main (208V)** | 120 A | 70 A | PASS (120% Commercial Busbar) |
| **800A Bus / 800A Main (208V)** | 160 A | 70 A | PASS (120% Commercial Busbar) |
| **1,200A Bus / 1,200A Main (208V)** | 240 A | 70 A | PASS (120% Commercial Busbar) |

## Which Competing Grid-Support Inverters Compare to Pika Energy: X11402 {208V}?

Peer 208 V, commercial single-phase CEC inverters near 11,187 W AC output such as EG4 Electronics LLC: IV-13000-HYB-AW-FX-xx {208V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**EG4 Electronics LLC: IV-13000-HYB-AW-FX-xx {208V}**](https://epri-peac.com/solar-equipment/inverters/eg4-electronics-llc/eg4-electronics-llc-iv-13000-hyb-aw-fx-xx-208v/) EG4 Electronics LLC | 11,325 W | +138 W | 208.0 V | 440.0 V | 96.79% |
| [**Chint Power Systems America: CPS ECH114KTL/US {208V}**](https://epri-peac.com/solar-equipment/inverters/chint-power-systems-america/chint-power-systems-america-cps-ech114ktl-us-208v/) Chint Power Systems America | 11,350 W | +163 W | 208.0 V | 480.0 V | 96.63% |
| [**EcoFlow Inc: EF-PCS-24 {208V 115kW}**](https://epri-peac.com/solar-equipment/inverters/ecoflow-inc/ecoflow-inc-ef-pcs-24-208v-115kw/) EcoFlow Inc | 11,444 W | +257 W | 208.0 V | 480.0 V | 96.52% |
| [**EG4 Electronics LLC: 18KPV-12LV {208V}**](https://epri-peac.com/solar-equipment/inverters/eg4-electronics-llc/eg4-electronics-llc-18kpv-12lv-208v/) EG4 Electronics LLC | 10,499 W | -688 W | 208.0 V | 480.0 V | 96.07% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Pika Energy: X11402 {208V}?

Check Pika Energy: X11402 {208V} (11,187 W AC, 70 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 208 V, commercial single-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 420 V DC on Pika Energy: X11402 {208V}.

### Pika Energy: X11402 {208V} Panel & Wire Spec

Size 75 C copper conductors at 4 AWG Cu on a 70 A OCPD breaker (53.8 A continuous).

### Alternative Inverter Comparison

Compare efficiency (96.99%) and MPPT window (390-420 V) directly against EG4 Electronics LLC: IV-13000-HYB-AW-FX-xx {208V} (11,325 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Pika Energy: X11402 {208V} by Pika Energy covering breaker sizing, MPPT limits, and 208 V, commercial single-phase interconnection.

### What breaker and wire size does Pika Energy: X11402 {208V} require?

At 11,187 W continuous AC (208 V, commercial single-phase), continuous current is 53.8 A; 125% NEC 690.8/705.12 sizing requires a 70 A breaker and 4 AWG Cu (75 C) wire.

### What commercial switchgear or feeder sizing does Pika Energy: X11402 {208V} require?

At 11,187 W AC and 208 V, commercial single-phase, continuous line current is 53.8 A, requiring a 70 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.

### How does Pika Energy: X11402 {208V} compare to EG4 Electronics LLC: IV-13000-HYB-AW-FX-xx {208V}?

Pika Energy: X11402 {208V} delivers 11,187 W AC at 96.99% CEC efficiency with a 420 V DC ceiling, while EG4 Electronics LLC: IV-13000-HYB-AW-FX-xx {208V} outputs 11,325 W at 208 V, commercial single-phase.

## Related Pages

Explore Pika Energy hardware, EG4 Electronics LLC: IV-13000-HYB-AW-FX-xx {208V}, utility rates, and NEC 705.12 sizing calculators alongside Pika Energy: X11402 {208V}.

[All Pika Energy Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/pika-energy/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Pika Energy

- [All Pika Energy Specs](https://epri-peac.com/solar-equipment/brands/pika-energy/)
- [Pika Energy: X11403 {208V}](https://epri-peac.com/solar-equipment/inverters/pika-energy/pika-energy-x11403-208v/)
- [Pika Energy: X7601 {240V}](https://epri-peac.com/solar-equipment/inverters/pika-energy/pika-energy-x7601-240v/)
- [Pika Energy: X7602 {240V}](https://epri-peac.com/solar-equipment/inverters/pika-energy/pika-energy-x7602-240v/)
- [Pika Energy: X7603 {240V}](https://epri-peac.com/solar-equipment/inverters/pika-energy/pika-energy-x7603-240v/)