title: "PhaseGreen Technology Inc Inverter (6,117W)"
url: https://epri-peac.com/solar-equipment/inverters/phasegreen-technology-inc/phasegreen-technology-inc-phg-p6k0lna-m-240v/
description: "CEC specs for PhaseGreen Technology Inc: PhG-P6K0LNA-M {240V}: 6,117W AC, 240V, 35A OCPD, and NEC 705.12 checks. Verified US government and CEC engineering data."
---

CEC Grid-Support Inverter

# PhaseGreen Technology Inc: PhG-P6K0LNA-M {240V} — CEC Inverter Specifications

Manufacturer: [**PhaseGreen Technology Inc**](https://epri-peac.com/solar-equipment/brands/phasegreen-technology-inc/) Registry: **CEC Verified Engineering Specification**

PhaseGreen Technology Inc: PhG-P6K0LNA-M {240V} outputs 6,117 W AC at 240 V (25.5 A continuous, 35 A OCPD), ranking #856 of 2,343 CEC inverters at 97.13% efficiency with a 200-430 V MPPT window and 430 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 6,117 W

- **AC Voltage** : 240 V

- **Min PV Breaker** : 35 A (8 AWG Cu)

- **CEC Efficiency** : 97.13%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does PhaseGreen Technology Inc: PhG-P6K0LNA-M {240V} Compare Against Peer CEC Listings?

Breaker sizing (35 A), 8 AWG Cu wire rules, and DC input limits for PhaseGreen Technology Inc: PhG-P6K0LNA-M {240V}.

For NEC 705.12 solar interconnection, PhaseGreen Technology Inc: PhG-P6K0LNA-M {240V} outputs 25.5 A continuous AC at 240 V and needs a 35 A backfeed breaker on 8 AWG Cu (75 C). Requires a 35 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit). Conversion efficiency scores 97.13% (#856 of 2,343, +0.31 pts vs overall CEC median).

## Where Does PhaseGreen Technology Inc: PhG-P6K0LNA-M {240V} Fall Across Listed CEC Models?

Output power comparison showing where PhaseGreen Technology Inc: PhG-P6K0LNA-M {240V} sits among all 2,343 CEC-listed grid-support inverters. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

## What Dataset Percentiles Define PhaseGreen Technology Inc: PhG-P6K0LNA-M {240V}?

Relative ranking of PhaseGreen Technology Inc: PhG-P6K0LNA-M {240V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

## What Do the Dataset Ranks Show for PhaseGreen Technology Inc: PhG-P6K0LNA-M {240V}?

Snapshot of PhaseGreen Technology Inc: PhG-P6K0LNA-M {240V} efficiency rank (#856), OCPD breaker size, MPPT span, and busbar verdict.

Eff #856 / 2,343

### 97.13% CEC Weighted Efficiency

+0.45 pts vs the 96.68% 240 V median; overall power rank #1,356 (6,117 W, below CEC median; higher than 42.0% of peers).

NEC 705.12 Check

### 35 A Required Backfeed OCPD

125% x 25.5 A = 31.9 A -> 35 A standard OCPD using 8 AWG Cu (75 C).

MPPT Window

### 200 V - 430 V (Max 430 V DC)

Tracking span of 230.0 V; listed since 2026-03-11 (hybrid battery-capable inverter).

Panel Fit (240V)

### PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 6117.0W / 240 V -> 25.5 A | Breaker >= 1.25 * 25.5 = 31.9 A -> 35 A

CEC Inverters.csv for PhaseGreen Technology Inc: PhG-P6K0LNA-M {240V}: Paco=6117.0 W, Vac=240 V, Vdcmax=430.0 V, Eff=97.13%.

**Result:** Min 35 A breaker & 8 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

## What Are the Published CEC Specifications for PhaseGreen Technology Inc: PhG-P6K0LNA-M {240V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for PhaseGreen Technology Inc: PhG-P6K0LNA-M {240V}. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Official California Energy Commission (NREL SAM) test parameters for PhaseGreen Technology Inc: PhG-P6K0LNA-M {240V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 6,117 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 430 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 200 V - 430 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 17.4937 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 97.13% | Calculated AC/DC conversion ratio from CEC test protocol |
| **CEC Listing Date & Hybrid** | 2026-03-11 / Hybrid: Yes (Battery Capable) | Utility interconnection approval metadata |

## Can a Residential Panel Meet 120% Busbar Limits for PhaseGreen Technology Inc: PhG-P6K0LNA-M {240V}?

NEC 705.12(B)(3)(2) backfeed compliance table for PhaseGreen Technology Inc: PhG-P6K0LNA-M {240V} at 240 V. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Evaluates PhaseGreen Technology Inc: PhG-P6K0LNA-M {240V} (35 A required OCPD at 240 V) across standard distribution busbars.

| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **100A Bus / 100A Main** | 20 A | 35 A | Needs Derate / Tap 705.11 |
| **150A Bus / 150A Main** | 30 A | 35 A | Needs Derate / Tap 705.11 |
| **200A Bus / 200A Main** | 40 A | 35 A | PASS (120% Rule) |
| **200A Bus / 175A Main** | 65 A | 35 A | PASS (120% Rule) |
| **225A Bus / 200A Main** | 70 A | 35 A | PASS (120% Rule) |

## Which CEC PV Module Strings Pair With PhaseGreen Technology Inc: PhG-P6K0LNA-M {240V}?

Minimum and maximum series solar module strings fitting PhaseGreen Technology Inc: PhG-P6K0LNA-M {240V} MPPT and 430 V limits.

Sampled CEC PV modules aligned within 200.0-430.0 V MPPT and 430.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 5 to 7 panels | 4.13 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 6 to 10 panels | 4.4 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 6 to 9 panels | 3.83 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 7 to 10 panels | 2.0 kW |

## Which Competing Grid-Support Inverters Compare to PhaseGreen Technology Inc: PhG-P6K0LNA-M {240V}?

Peer 240 V CEC inverters near 6,117 W AC output such as Amensolar Ess Co Ltd: N3H-X60-US {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Amensolar Ess Co Ltd: N3H-X60-US {240V}**](https://epri-peac.com/solar-equipment/inverters/amensolar-ess-co-ltd/amensolar-ess-co-ltd-n3h-x60-us-240v/) Amensolar Ess Co Ltd | 6,117 W | Tie (0 W) | 240.0 V | 430.0 V | 97.13% |
| [**Anker Innovations Limited: X1-P6K-US {240V}**](https://epri-peac.com/solar-equipment/inverters/anker-innovations-limited/anker-innovations-limited-x1-p6k-us-240v/) Anker Innovations Limited | 6,040 W | -77 W | 240.0 V | 450.0 V | 97.43% |
| [**Dyness Digital Energy Technology Co LTD: TX6K-AM {240V}**](https://epri-peac.com/solar-equipment/inverters/dyness-digital-energy-technology-co-ltd/dyness-digital-energy-technology-co-ltd-tx6k-am-240v/) Dyness Digital Energy Technology Co LTD | 6,028 W | -89 W | 240.0 V | 490.0 V | 96.68% |
| [**Dyness Digital Energy Technology Co LTD: TX6K-HM {240V}**](https://epri-peac.com/solar-equipment/inverters/dyness-digital-energy-technology-co-ltd/dyness-digital-energy-technology-co-ltd-tx6k-hm-240v/) Dyness Digital Energy Technology Co LTD | 6,018 W | -99 W | 240.0 V | 500.0 V | 97.0% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for PhaseGreen Technology Inc: PhG-P6K0LNA-M {240V}?

Check PhaseGreen Technology Inc: PhG-P6K0LNA-M {240V} (6,117 W AC, 35 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Requires a 35 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 430 V DC on PhaseGreen Technology Inc: PhG-P6K0LNA-M {240V}.

### PhaseGreen Technology Inc: PhG-P6K0LNA-M {240V} Panel & Wire Spec

Size 75 C copper conductors at 8 AWG Cu on a 35 A OCPD breaker (25.5 A continuous).

### Alternative Inverter Comparison

Compare efficiency (97.13%) and MPPT window (200-430 V) directly against Amensolar Ess Co Ltd: N3H-X60-US {240V} (6,117 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for PhaseGreen Technology Inc: PhG-P6K0LNA-M {240V} by PhaseGreen Technology Inc covering breaker sizing, MPPT limits, and 240 V interconnection.

### What breaker and wire size does PhaseGreen Technology Inc: PhG-P6K0LNA-M {240V} require?

At 6,117 W continuous AC (240 V), continuous current is 25.5 A; 125% NEC 690.8/705.12 sizing requires a 35 A breaker and 8 AWG Cu (75 C) wire.

### Does PhaseGreen Technology Inc: PhG-P6K0LNA-M {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 35 A at 240 V means PASS (120% Rule).

### How does PhaseGreen Technology Inc: PhG-P6K0LNA-M {240V} compare to Amensolar Ess Co Ltd: N3H-X60-US {240V}?

PhaseGreen Technology Inc: PhG-P6K0LNA-M {240V} delivers 6,117 W AC at 97.13% CEC efficiency with a 430 V DC ceiling, while Amensolar Ess Co Ltd: N3H-X60-US {240V} outputs 6,117 W at 240 V.

## Related Pages

Explore PhaseGreen Technology Inc hardware, Amensolar Ess Co Ltd: N3H-X60-US {240V}, utility rates, and NEC 705.12 sizing calculators alongside PhaseGreen Technology Inc: PhG-P6K0LNA-M {240V}.

[All PhaseGreen Technology Inc Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/phasegreen-technology-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From PhaseGreen Technology Inc

- [All PhaseGreen Technology Inc Specs](https://epri-peac.com/solar-equipment/brands/phasegreen-technology-inc/)
- [PhaseGreen Technology Inc: PhG-P10K0LNA-M {240V}](https://epri-peac.com/solar-equipment/inverters/phasegreen-technology-inc/phasegreen-technology-inc-phg-p10k0lna-m-240v/)
- [PhaseGreen Technology Inc: PhG-P8K0LNA-M {240V}](https://epri-peac.com/solar-equipment/inverters/phasegreen-technology-inc/phasegreen-technology-inc-phg-p8k0lna-m-240v/)
- [PhaseGreen Technology Inc: PhG-P7K6LNA-M {240V}](https://epri-peac.com/solar-equipment/inverters/phasegreen-technology-inc/phasegreen-technology-inc-phg-p7k6lna-m-240v/)
- [PhaseGreen Technology Inc: PhG-P5K0LNA-M {240V}](https://epri-peac.com/solar-equipment/inverters/phasegreen-technology-inc/phasegreen-technology-inc-phg-p5k0lna-m-240v/)