title: "OutBack Power: VFXR3648A {120V} Inverter (3,037W)"
url: https://epri-peac.com/solar-equipment/inverters/outback-power/outback-power-vfxr3648a-120v/
description: "CEC specs for OutBack Power: VFXR3648A {120V}: 3,037W AC, 120V, 35A OCPD, and NEC 705.12 checks. Verified US government and CEC engineering data."
---

CEC Grid-Support Inverter

# OutBack Power: VFXR3648A {120V} — CEC Inverter Specifications

Manufacturer: [**OutBack Power**](https://epri-peac.com/solar-equipment/brands/outback-power/) Registry: **CEC Verified Engineering Specification**

OutBack Power: VFXR3648A {120V} outputs 3,037 W AC at 120 V (25.3 A continuous, 35 A OCPD), ranking #2,340 of 2,343 CEC inverters at 89.72% efficiency with a 40-60 V MPPT window and 60 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 3,037 W

- **AC Voltage** : 120 V

- **Min PV Breaker** : 35 A (8 AWG Cu)

- **CEC Efficiency** : 89.72%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does OutBack Power: VFXR3648A {120V} Compare Against Peer CEC Listings?

Breaker sizing (35 A), 8 AWG Cu wire rules, and DC input limits for OutBack Power: VFXR3648A {120V}.

For NEC 705.12 solar interconnection, OutBack Power: VFXR3648A {120V} outputs 25.3 A continuous AC at 120 V and needs a 35 A backfeed breaker on 8 AWG Cu (75 C). Requires a 35 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit). Conversion efficiency scores 89.72% (#2,340 of 2,343, -7.10 pts vs overall CEC median).

## Where Does OutBack Power: VFXR3648A {120V} Fall Across Listed CEC Models?

Output power comparison showing where OutBack Power: VFXR3648A {120V} sits among all 2,343 CEC-listed grid-support inverters. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

## What Dataset Percentiles Define OutBack Power: VFXR3648A {120V}?

Relative ranking of OutBack Power: VFXR3648A {120V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

## What Do the Dataset Ranks Show for OutBack Power: VFXR3648A {120V}?

Snapshot of OutBack Power: VFXR3648A {120V} efficiency rank (#2,340), OCPD breaker size, MPPT span, and busbar verdict. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Eff #2,340 / 2,343

### 89.72% CEC Weighted Efficiency

-5.01 pts vs the 94.73% 120 V median; overall power rank #1,726 (3,037 W, below CEC median; higher than 26.3% of peers).

NEC 705.12 Check

### 35 A Required Backfeed OCPD

125% x 25.3 A = 31.6 A -> 35 A standard OCPD using 8 AWG Cu (75 C).

MPPT Window

### 40 V - 60 V (Max 60 V DC)

Tracking span of 20.0 V; listed since 2018-10-15 (grid-tied PV inverter).

Panel Fit (240V)

### 120V AC Coupled / Dedicated Transformer

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 3037.0W / 120 V -> 25.3 A | Breaker >= 1.25 * 25.3 = 31.6 A -> 35 A

CEC Inverters.csv for OutBack Power: VFXR3648A {120V}: Paco=3037.0 W, Vac=120 V, Vdcmax=60.0 V, Eff=89.72%.

**Result:** Min 35 A breaker & 8 AWG Cu (75 C); 200A Bus / 200A Main: 120V AC Coupled / Dedicated Transformer.

## What Are the Published CEC Specifications for OutBack Power: VFXR3648A {120V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for OutBack Power: VFXR3648A {120V}. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Official California Energy Commission (NREL SAM) test parameters for OutBack Power: VFXR3648A {120V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 3,037 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 120 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 60 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 40 V - 60 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 66.1133 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 89.72% | Calculated AC/DC conversion ratio from CEC test protocol |
| **CEC Listing Date & Hybrid** | 2018-10-15 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |

## Can a Residential Panel Meet 120% Busbar Limits for OutBack Power: VFXR3648A {120V}?

NEC 705.12(B)(3)(2) backfeed compliance table for OutBack Power: VFXR3648A {120V} at 120 V. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Evaluates OutBack Power: VFXR3648A {120V} (35 A required OCPD at 120 V) across standard distribution busbars.

| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **100A Bus / 100A Main** | 20 A | 35 A | 120V AC Coupled / Dedicated Transformer |
| **150A Bus / 150A Main** | 30 A | 35 A | 120V AC Coupled / Dedicated Transformer |
| **200A Bus / 200A Main** | 40 A | 35 A | 120V AC Coupled / Dedicated Transformer |
| **200A Bus / 175A Main** | 65 A | 35 A | 120V AC Coupled / Dedicated Transformer |
| **225A Bus / 200A Main** | 70 A | 35 A | 120V AC Coupled / Dedicated Transformer |

## Which CEC PV Module Strings Pair With OutBack Power: VFXR3648A {120V}?

Minimum and maximum series solar module strings fitting OutBack Power: VFXR3648A {120V} MPPT and 60 V limits. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sampled CEC PV modules aligned within 40.0-60.0 V MPPT and 60.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 1 panel (micro/module) | 0.59 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 1 panel (micro/module) | 0.44 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 1 panel (micro/module) | 0.42 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 1 panel (micro/module) | 0.2 kW |

## Which Competing Grid-Support Inverters Compare to OutBack Power: VFXR3648A {120V}?

Peer 120 V CEC inverters near 3,037 W AC output such as Northern Electric & Power Co Ltd: BDM-1600-LV {120V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Northern Electric & Power Co Ltd: BDM-1600-LV {120V}**](https://epri-peac.com/solar-equipment/inverters/northern-electric-power-co-ltd/northern-electric-power-co-ltd-bdm-1600-lv-120v/) Northern Electric & Power Co Ltd | 1,597 W | -1440 W | 120.0 V | 55.0 V | 96.31% |
| [**Power Center: Essential Hybrid 5 {120V}**](https://epri-peac.com/solar-equipment/inverters/power-center/power-center-essential-hybrid-5-120v/) Power Center | 4,787 W | +1750 W | 120.0 V | 425.0 V | 95.59% |
| [**Sol-Ark: 5K-120V/8K-230V-1P {120V}**](https://epri-peac.com/solar-equipment/inverters/sol-ark/sol-ark-5k-120v-8k-230v-1p-120v/) Sol-Ark | 4,787 W | +1750 W | 120.0 V | 425.0 V | 95.59% |
| [**Northern Electric & Power Co Ltd: BDM-1200-LV {120V}**](https://epri-peac.com/solar-equipment/inverters/northern-electric-power-co-ltd/northern-electric-power-co-ltd-bdm-1200-lv-120v/) Northern Electric & Power Co Ltd | 1,194 W | -1844 W | 120.0 V | 55.0 V | 96.23% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for OutBack Power: VFXR3648A {120V}?

Check OutBack Power: VFXR3648A {120V} (3,037 W AC, 35 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Requires a 35 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 60 V DC on OutBack Power: VFXR3648A {120V}.

### OutBack Power: VFXR3648A {120V} Panel & Wire Spec

Size 75 C copper conductors at 8 AWG Cu on a 35 A OCPD breaker (25.3 A continuous).

### Alternative Inverter Comparison

Compare efficiency (89.72%) and MPPT window (40-60 V) directly against Northern Electric & Power Co Ltd: BDM-1600-LV {120V} (1,597 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for OutBack Power: VFXR3648A {120V} by OutBack Power covering breaker sizing, MPPT limits, and 120 V interconnection.

### What breaker and wire size does OutBack Power: VFXR3648A {120V} require?

At 3,037 W continuous AC (120 V), continuous current is 25.3 A; 125% NEC 690.8/705.12 sizing requires a 35 A breaker and 8 AWG Cu (75 C) wire.

### Does OutBack Power: VFXR3648A {120V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 35 A at 120 V means 120V AC Coupled / Dedicated Transformer.

### How does OutBack Power: VFXR3648A {120V} compare to Northern Electric & Power Co Ltd: BDM-1600-LV {120V}?

OutBack Power: VFXR3648A {120V} delivers 3,037 W AC at 89.72% CEC efficiency with a 60 V DC ceiling, while Northern Electric & Power Co Ltd: BDM-1600-LV {120V} outputs 1,597 W at 120 V.

## Related Pages

Explore OutBack Power hardware, Northern Electric & Power Co Ltd: BDM-1600-LV {120V}, utility rates, and NEC 705.12 sizing calculators alongside OutBack Power: VFXR3648A {120V}.

[All OutBack Power Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/outback-power/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From OutBack Power

- [All OutBack Power Specs](https://epri-peac.com/solar-equipment/brands/outback-power/)
- [OutBack Power: PHXL480-10k {480V}](https://epri-peac.com/solar-equipment/inverters/outback-power/outback-power-phxl480-10k-480v/)
- [OutBack Power: OGHI8048A {240V}](https://epri-peac.com/solar-equipment/inverters/outback-power/outback-power-oghi8048a-240v/)
- [OutBack Power: GS8048A {240V}](https://epri-peac.com/solar-equipment/inverters/outback-power/outback-power-gs8048a-240v/)
- [OutBack Power: SBX5048-120/240 {240V}](https://epri-peac.com/solar-equipment/inverters/outback-power/outback-power-sbx5048-120-240-240v/)
- [OutBack Power: GS4048A {240V}](https://epri-peac.com/solar-equipment/inverters/outback-power/outback-power-gs4048a-240v/)