---
title: "Northern Electric & Power Co Ltd Inverter (576W)"
url: https://epri-peac.com/solar-equipment/inverters/northern-electric-power-co-ltd/northern-electric-power-co-ltd-bdm-300x2-240a-240v/
description: "CEC specs for Northern Electric & Power Co Ltd: BDM-300X2-240A {240V}: 576W AC, 240V, 15A OCPD, and NEC 705.12 checks. Source-verified US engineering data."
---

CEC Grid-Support Inverter

# Northern Electric & Power Co Ltd: BDM-300X2-240A {240V} — CEC Inverter Specifications

Manufacturer: [**Northern Electric & Power Co Ltd**](https://epri-peac.com/solar-equipment/brands/northern-electric-power-co-ltd/) Registry: **CEC Verified Engineering Specification**

Northern Electric & Power Co Ltd: BDM-300X2-240A {240V} outputs 576 W AC at 240 V (2.4 A continuous, 15 A OCPD), ranking #1,776 of 2,343 CEC inverters at 96.29% efficiency with a 22-55 V MPPT window and 55 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 576 W

- **AC Voltage** : 240 V

- **Min PV Breaker** : 15 A (14 AWG Cu)

- **CEC Efficiency** : 96.29%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Northern Electric & Power Co Ltd: BDM-300X2-240A {240V} Compare Against Peer CEC Listings?

How Northern Electric & Power Co Ltd Northern Electric & Power Co Ltd: BDM-300X2-240A {240V} compares on 96.29% efficiency, MPPT span, and 120% busbar interconnection.

Northern Electric & Power Co Ltd certifies Northern Electric & Power Co Ltd: BDM-300X2-240A {240V} (grid-tied PV inverter, listed since 2025-11-12) at 576 W AC (5,200 W below the 5,776 W 240 V median). Its 55 V DC ceiling pairs with an MPPT window of 22-55 V (span 33.0 V). Under NEC 690.8/705.12, 125% sizing demands 14 AWG Cu conductors on a 15 A OCPD.

## Where Does Northern Electric & Power Co Ltd: BDM-300X2-240A {240V} Fall Across Listed CEC Models?

Position of Northern Electric & Power Co Ltd: BDM-300X2-240A {240V} (576 W AC) relative to the 7,680 W CEC median inverter.

## What Dataset Percentiles Define Northern Electric & Power Co Ltd: BDM-300X2-240A {240V}?

Percentile placement of Northern Electric & Power Co Ltd: BDM-300X2-240A {240V} across AC power class, conversion efficiency, and backfeed breaker size.

## What Do the Dataset Ranks Show for Northern Electric & Power Co Ltd: BDM-300X2-240A {240V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for Northern Electric & Power Co Ltd: BDM-300X2-240A {240V}.

Eff #1,776 / 2,343

### 96.29% CEC Weighted Efficiency

-0.39 pts vs the 96.68% 240 V median; overall power rank #1,937 (576 W, below CEC median; higher than 17.3% of peers).

NEC 705.12 Check

### 15 A Required Backfeed OCPD

125% x 2.4 A = 3.0 A -> 15 A standard OCPD using 14 AWG Cu (75 C).

MPPT Window

### 22 V - 55 V (Max 55 V DC)

Tracking span of 33.0 V; listed since 2025-11-12 (grid-tied PV inverter).

Panel Fit (240V)

### PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 576.0W / 240 V -> 2.4 A | Breaker >= 1.25 * 2.4 = 3.0 A -> 15 A

CEC Inverters.csv for Northern Electric & Power Co Ltd: BDM-300X2-240A {240V}: Paco=576.0 W, Vac=240 V, Vdcmax=55.0 V, Eff=96.29%.

**Result:** Min 15 A breaker & 14 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

## What Are the Published CEC Specifications for Northern Electric & Power Co Ltd: BDM-300X2-240A {240V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for Northern Electric & Power Co Ltd: BDM-300X2-240A {240V}.

Official California Energy Commission (NREL SAM) test parameters for Northern Electric & Power Co Ltd: BDM-300X2-240A {240V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 576 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 55 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 22 V - 55 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 17.0919 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 96.29% | Calculated AC/DC conversion ratio from CEC test protocol |
| **CEC Listing Date & Hybrid** | 2025-11-12 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |

## Can a Residential Panel Meet 120% Busbar Limits for Northern Electric & Power Co Ltd: BDM-300X2-240A {240V}?

Check whether Northern Electric & Power Co Ltd: BDM-300X2-240A {240V} (15 A breaker) fits without main breaker derate or supply-side taps.

Evaluates Northern Electric & Power Co Ltd: BDM-300X2-240A {240V} (15 A required OCPD at 240 V) across standard distribution busbars.

| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **100A Bus / 100A Main** | 20 A | 15 A | PASS (120% Rule) |
| **150A Bus / 150A Main** | 30 A | 15 A | PASS (120% Rule) |
| **200A Bus / 200A Main** | 40 A | 15 A | PASS (120% Rule) |
| **200A Bus / 175A Main** | 65 A | 15 A | PASS (120% Rule) |
| **225A Bus / 200A Main** | 70 A | 15 A | PASS (120% Rule) |

## Which CEC PV Module Strings Pair With Northern Electric & Power Co Ltd: BDM-300X2-240A {240V}?

Verified cold-weather (-10 C) series module counts matched to Northern Electric & Power Co Ltd: BDM-300X2-240A {240V}'s 55 V DC ceiling.

Sampled CEC PV modules aligned within 22.0-55.0 V MPPT and 55.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 1 panel (micro/module) | 0.44 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 1 panel (micro/module) | 0.42 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 1 panel (micro/module) | 0.2 kW |
| [**Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-515**](https://epri-peac.com/solar-equipment/modules/chint-new-energy-technology-co-ltd/chint-new-energy-technology-co-ltd-chsm72m-dg-f-bh-515/) | 515.0 W | 53.76 V | 1 panel (micro/module) | 0.52 kW |

## Which Competing Grid-Support Inverters Compare to Northern Electric & Power Co Ltd: BDM-300X2-240A {240V}?

Alternative CEC inverters comparable to Northern Electric & Power Co Ltd: BDM-300X2-240A {240V}, including Altenergy Power System Inc: YC600 {240V} (550 W) at 240 V.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Altenergy Power System Inc: YC600 {240V}**](https://epri-peac.com/solar-equipment/inverters/altenergy-power-system-inc/altenergy-power-system-inc-yc600-240v/) Altenergy Power System Inc | 550 W | -26 W | 240.0 V | 45.0 V | 96.51% |
| [**Cherry Solution Co Ltd: CMI-600S-SA {240V}**](https://epri-peac.com/solar-equipment/inverters/cherry-solution-co-ltd/cherry-solution-co-ltd-cmi-600s-sa-240v/) Cherry Solution Co Ltd | 604 W | +28 W | 240.0 V | 50.0 V | 96.12% |
| [**Cherry Solution Co Ltd: CMI-600S-WA {240V}**](https://epri-peac.com/solar-equipment/inverters/cherry-solution-co-ltd/cherry-solution-co-ltd-cmi-600s-wa-240v/) Cherry Solution Co Ltd | 604 W | +28 W | 240.0 V | 50.0 V | 96.12% |
| [**Altenergy Power System Inc: DS3-S {240V}**](https://epri-peac.com/solar-equipment/inverters/altenergy-power-system-inc/altenergy-power-system-inc-ds3-s-240v/) Altenergy Power System Inc | 656 W | +80 W | 240.0 V | 43.0 V | 97.23% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Northern Electric & Power Co Ltd: BDM-300X2-240A {240V}?

Check Northern Electric & Power Co Ltd: BDM-300X2-240A {240V} (576 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 55 V DC on Northern Electric & Power Co Ltd: BDM-300X2-240A {240V}.

### Northern Electric & Power Co Ltd: BDM-300X2-240A {240V} Panel & Wire Spec

Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (2.4 A continuous).

### Alternative Inverter Comparison

Compare efficiency (96.29%) and MPPT window (22-55 V) directly against Altenergy Power System Inc: YC600 {240V} (550 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Northern Electric & Power Co Ltd: BDM-300X2-240A {240V} by Northern Electric & Power Co Ltd covering breaker sizing, MPPT limits, and 240 V interconnection.

### What breaker and wire size does Northern Electric & Power Co Ltd: BDM-300X2-240A {240V} require?

At 576 W continuous AC (240 V), continuous current is 2.4 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.

### Does Northern Electric & Power Co Ltd: BDM-300X2-240A {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 15 A at 240 V means PASS (120% Rule).

### How does Northern Electric & Power Co Ltd: BDM-300X2-240A {240V} compare to Altenergy Power System Inc: YC600 {240V}?

Northern Electric & Power Co Ltd: BDM-300X2-240A {240V} delivers 576 W AC at 96.29% CEC efficiency with a 55 V DC ceiling, while Altenergy Power System Inc: YC600 {240V} outputs 550 W at 240 V.

## Related Pages

Explore Northern Electric & Power Co Ltd hardware, Altenergy Power System Inc: YC600 {240V}, utility rates, and NEC 705.12 sizing calculators alongside Northern Electric & Power Co Ltd: BDM-300X2-240A {240V}.

[All Northern Electric & Power Co Ltd Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/northern-electric-power-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Northern Electric & Power Co Ltd

- [All Northern Electric & Power Co Ltd Specs](https://epri-peac.com/solar-equipment/brands/northern-electric-power-co-ltd/)
- [Northern Electric & Power Co Ltd: Neptune100K {480V}](https://epri-peac.com/solar-equipment/inverters/northern-electric-power-co-ltd/northern-electric-power-co-ltd-neptune100k-480v/)
- [Northern Electric & Power Co Ltd: Neptune75K {480V}](https://epri-peac.com/solar-equipment/inverters/northern-electric-power-co-ltd/northern-electric-power-co-ltd-neptune75k-480v/)
- [Northern Electric & Power Co Ltd: Neptune60K {480V}](https://epri-peac.com/solar-equipment/inverters/northern-electric-power-co-ltd/northern-electric-power-co-ltd-neptune60k-480v/)
- [Northern Electric & Power Co Ltd: Neptune50K {480V}](https://epri-peac.com/solar-equipment/inverters/northern-electric-power-co-ltd/northern-electric-power-co-ltd-neptune50k-480v/)
- [Northern Electric & Power Co Ltd: Neptune40K {480V}](https://epri-peac.com/solar-equipment/inverters/northern-electric-power-co-ltd/northern-electric-power-co-ltd-neptune40k-480v/)
