title: "Northern Electric & Power Co Ltd Inverter (1,070W)"
url: https://epri-peac.com/solar-equipment/inverters/northern-electric-power-co-ltd/northern-electric-power-co-ltd-bdm-1200-208a-208v/
description: "CEC specs for Northern Electric & Power Co Ltd: BDM-1200-208A {208V}: 1,070W AC, 208V, 15A OCPD, and NEC 705.12 checks. Source-verified US engineering data."
---

CEC Grid-Support Inverter

# Northern Electric & Power Co Ltd: BDM-1200-208A {208V} — CEC Inverter Specifications

Manufacturer: [**Northern Electric & Power Co Ltd**](https://epri-peac.com/solar-equipment/brands/northern-electric-power-co-ltd/) Registry: **CEC Verified Engineering Specification**

Northern Electric & Power Co Ltd: BDM-1200-208A {208V} outputs 1,070 W AC at 208 V, commercial single-phase (5.1 A continuous, 15 A OCPD), ranking #1,589 of 2,343 CEC inverters at 96.48% efficiency with a 22-55 V MPPT window and 55 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 1,070 W

- **AC Voltage** : 208 V, commercial single-phase

- **Min PV Breaker** : 15 A (14 AWG Cu)

- **CEC Efficiency** : 96.48%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Northern Electric & Power Co Ltd: BDM-1200-208A {208V} Compare Against Peer CEC Listings?

CEC efficiency rank (#1,589), 22-55 V MPPT tracking, and panel fit for Northern Electric & Power Co Ltd: BDM-1200-208A {208V}.

Northern Electric & Power Co Ltd: BDM-1200-208A {208V} from Northern Electric & Power Co Ltd outputs 5.1 A continuous AC at 208 V, commercial single-phase (1,070 W AC, rank #1,817). Paired with 14 AWG Cu conductors and a 15 A OCPD, its 96.48% CEC efficiency compares closely with Cherry Solution Co Ltd: CMI-1000S-SA {208V} (994 W). Keep NEC 690.7 winter string Voc below 55 V DC.

## Where Does Northern Electric & Power Co Ltd: BDM-1200-208A {208V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting Northern Electric & Power Co Ltd: BDM-1200-208A {208V} at 1,070 W continuous AC output.

## What Dataset Percentiles Define Northern Electric & Power Co Ltd: BDM-1200-208A {208V}?

Dataset percentiles comparing Northern Electric & Power Co Ltd: BDM-1200-208A {208V} against 2,343 certified grid-support inverters nationwide. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

## What Do the Dataset Ranks Show for Northern Electric & Power Co Ltd: BDM-1200-208A {208V}?

Engineering highlights for Northern Electric & Power Co Ltd: BDM-1200-208A {208V} covering efficiency, 14 AWG Cu feeder, and panel compatibility.

Eff #1,589 / 2,343

### 96.48% CEC Weighted Efficiency

+0.07 pts vs the 96.41% 208 V median; overall power rank #1,817 (1,070 W, below CEC median; higher than 22.4% of peers).

NEC 705.12 Check

### 15 A Required Backfeed OCPD

125% x 5.1 A = 6.4 A -> 15 A standard OCPD using 14 AWG Cu (75 C).

MPPT Window

### 22 V - 55 V (Max 55 V DC)

Tracking span of 33.0 V; listed since 2025-11-12 (grid-tied PV inverter).

Commercial / 3-Phase Fit

### PASS (120% Commercial Busbar)

Evaluated for 208 V, commercial single-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 1070.0W / 208 V -> 5.1 A | Breaker >= 1.25 * 5.1 = 6.4 A -> 15 A

CEC Inverters.csv for Northern Electric & Power Co Ltd: BDM-1200-208A {208V}: Paco=1070.0 W, Vac=208 V, Vdcmax=55.0 V, Eff=96.48%.

**Result:** Min 15 A breaker & 14 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).

## What Are the Published CEC Specifications for Northern Electric & Power Co Ltd: BDM-1200-208A {208V}?

California Energy Commission Solar Equipment List parameters for Northern Electric & Power Co Ltd: BDM-1200-208A {208V} (grid-tied PV inverter) interconnection.

Official California Energy Commission (NREL SAM) test parameters for Northern Electric & Power Co Ltd: BDM-1200-208A {208V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 1,070 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 208 V, commercial single-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 55 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 22 V - 55 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 31.6874 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 96.48% | Calculated AC/DC conversion ratio from CEC test protocol |
| **CEC Listing Date & Hybrid** | 2025-11-12 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |

## What Switchgear Limits Apply to Northern Electric & Power Co Ltd: BDM-1200-208A {208V} (208 V, commercial single-phase)?

Panelboard and switchgear backfeed allowances for Northern Electric & Power Co Ltd: BDM-1200-208A {208V} (15 A OCPD). All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Evaluates Northern Electric & Power Co Ltd: BDM-1200-208A {208V} (15 A required OCPD at 208 V, commercial single-phase) across standard distribution busbars.

| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **200A Bus / 200A Main (208V)** | 40 A | 15 A | PASS (120% Commercial Busbar) |
| **400A Bus / 400A Main (208V)** | 80 A | 15 A | PASS (120% Commercial Busbar) |
| **600A Bus / 600A Main (208V)** | 120 A | 15 A | PASS (120% Commercial Busbar) |
| **800A Bus / 800A Main (208V)** | 160 A | 15 A | PASS (120% Commercial Busbar) |
| **1,200A Bus / 1,200A Main (208V)** | 240 A | 15 A | PASS (120% Commercial Busbar) |

## Which CEC PV Module Strings Pair With Northern Electric & Power Co Ltd: BDM-1200-208A {208V}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for Northern Electric & Power Co Ltd: BDM-1200-208A {208V}.

Sampled CEC PV modules aligned within 22.0-55.0 V MPPT and 55.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 1 panel (micro/module) | 0.44 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 1 panel (micro/module) | 0.42 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 1 panel (micro/module) | 0.2 kW |
| [**Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-515**](https://epri-peac.com/solar-equipment/modules/chint-new-energy-technology-co-ltd/chint-new-energy-technology-co-ltd-chsm72m-dg-f-bh-515/) | 515.0 W | 53.76 V | 1 panel (micro/module) | 0.52 kW |

## Which Competing Grid-Support Inverters Compare to Northern Electric & Power Co Ltd: BDM-1200-208A {208V}?

Four alternative CEC inverters matched to Northern Electric & Power Co Ltd: BDM-1200-208A {208V} (1,070 W AC), led by Cherry Solution Co Ltd: CMI-1000S-SA {208V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Cherry Solution Co Ltd: CMI-1000S-SA {208V}**](https://epri-peac.com/solar-equipment/inverters/cherry-solution-co-ltd/cherry-solution-co-ltd-cmi-1000s-sa-208v/) Cherry Solution Co Ltd | 994 W | -76 W | 208.0 V | 50.0 V | 96.35% |
| [**Cherry Solution Co Ltd: CMI-1000S-WA {208V}**](https://epri-peac.com/solar-equipment/inverters/cherry-solution-co-ltd/cherry-solution-co-ltd-cmi-1000s-wa-208v/) Cherry Solution Co Ltd | 994 W | -76 W | 208.0 V | 50.0 V | 96.35% |
| [**Altenergy Power System Inc: QS1 {208V}**](https://epri-peac.com/solar-equipment/inverters/altenergy-power-system-inc/altenergy-power-system-inc-qs1-208v/) Altenergy Power System Inc | 1,218 W | +148 W | 208.0 V | 48.0 V | 95.82% |
| [**Cherry Solution Co Ltd: CMI-800S-SA {208V}**](https://epri-peac.com/solar-equipment/inverters/cherry-solution-co-ltd/cherry-solution-co-ltd-cmi-800s-sa-208v/) Cherry Solution Co Ltd | 800 W | -270 W | 208.0 V | 50.0 V | 95.84% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Northern Electric & Power Co Ltd: BDM-1200-208A {208V}?

Check Northern Electric & Power Co Ltd: BDM-1200-208A {208V} (1,070 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 208 V, commercial single-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 55 V DC on Northern Electric & Power Co Ltd: BDM-1200-208A {208V}.

### Northern Electric & Power Co Ltd: BDM-1200-208A {208V} Panel & Wire Spec

Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (5.1 A continuous).

### Alternative Inverter Comparison

Compare efficiency (96.48%) and MPPT window (22-55 V) directly against Cherry Solution Co Ltd: CMI-1000S-SA {208V} (994 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Northern Electric & Power Co Ltd: BDM-1200-208A {208V} by Northern Electric & Power Co Ltd covering breaker sizing, MPPT limits, and 208 V, commercial single-phase interconnection.

### What breaker and wire size does Northern Electric & Power Co Ltd: BDM-1200-208A {208V} require?

At 1,070 W continuous AC (208 V, commercial single-phase), continuous current is 5.1 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.

### What commercial switchgear or feeder sizing does Northern Electric & Power Co Ltd: BDM-1200-208A {208V} require?

At 1,070 W AC and 208 V, commercial single-phase, continuous line current is 5.1 A, requiring a 15 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.

### How does Northern Electric & Power Co Ltd: BDM-1200-208A {208V} compare to Cherry Solution Co Ltd: CMI-1000S-SA {208V}?

Northern Electric & Power Co Ltd: BDM-1200-208A {208V} delivers 1,070 W AC at 96.48% CEC efficiency with a 55 V DC ceiling, while Cherry Solution Co Ltd: CMI-1000S-SA {208V} outputs 994 W at 208 V, commercial single-phase.

## Related Pages

Explore Northern Electric & Power Co Ltd hardware, Cherry Solution Co Ltd: CMI-1000S-SA {208V}, utility rates, and NEC 705.12 sizing calculators alongside Northern Electric & Power Co Ltd: BDM-1200-208A {208V}.

[All Northern Electric & Power Co Ltd Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/northern-electric-power-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Northern Electric & Power Co Ltd

- [All Northern Electric & Power Co Ltd Specs](https://epri-peac.com/solar-equipment/brands/northern-electric-power-co-ltd/)
- [Northern Electric & Power Co Ltd: Neptune100K {480V}](https://epri-peac.com/solar-equipment/inverters/northern-electric-power-co-ltd/northern-electric-power-co-ltd-neptune100k-480v/)
- [Northern Electric & Power Co Ltd: Neptune75K {480V}](https://epri-peac.com/solar-equipment/inverters/northern-electric-power-co-ltd/northern-electric-power-co-ltd-neptune75k-480v/)
- [Northern Electric & Power Co Ltd: Neptune60K {480V}](https://epri-peac.com/solar-equipment/inverters/northern-electric-power-co-ltd/northern-electric-power-co-ltd-neptune60k-480v/)
- [Northern Electric & Power Co Ltd: Neptune50K {480V}](https://epri-peac.com/solar-equipment/inverters/northern-electric-power-co-ltd/northern-electric-power-co-ltd-neptune50k-480v/)
- [Northern Electric & Power Co Ltd: Neptune40K {480V}](https://epri-peac.com/solar-equipment/inverters/northern-electric-power-co-ltd/northern-electric-power-co-ltd-neptune40k-480v/)