title: "NeoVolta Inc: NV7600 {208V} Inverter (7,447W)"
url: https://epri-peac.com/solar-equipment/inverters/neovolta-inc/neovolta-inc-nv7600-208v/
description: "CEC specs for NeoVolta Inc: NV7600 {208V}: 7,447W AC, 208V, 45A OCPD, and NEC 705.12 checks. Verified US government and CEC engineering data."
---

CEC Grid-Support Inverter

# NeoVolta Inc: NV7600 {208V} — CEC Inverter Specifications

Manufacturer: [**NeoVolta Inc**](https://epri-peac.com/solar-equipment/brands/neovolta-inc/) Registry: **CEC Verified Engineering Specification**

NeoVolta Inc: NV7600 {208V} outputs 7,447 W AC at 208 V, commercial single-phase (35.8 A continuous, 45 A OCPD), ranking #1,044 of 2,343 CEC inverters at 96.98% efficiency with a 240-425 V MPPT window and 425 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 7,447 W

- **AC Voltage** : 208 V, commercial single-phase

- **Min PV Breaker** : 45 A (8 AWG Cu)

- **CEC Efficiency** : 96.98%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does NeoVolta Inc: NV7600 {208V} Compare Against Peer CEC Listings?

Breaker sizing (45 A), 8 AWG Cu wire rules, and DC input limits for NeoVolta Inc: NV7600 {208V}.

For NEC 705.12 solar interconnection, NeoVolta Inc: NV7600 {208V} outputs 35.8 A continuous AC at 208 V, commercial single-phase and needs a 45 A backfeed breaker on 8 AWG Cu (75 C). Commercial 208 V, commercial single-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap. Conversion efficiency scores 96.98% (#1,044 of 2,343, +0.16 pts vs overall CEC median).

## Where Does NeoVolta Inc: NV7600 {208V} Fall Across Listed CEC Models?

Output power comparison showing where NeoVolta Inc: NV7600 {208V} sits among all 2,343 CEC-listed grid-support inverters. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

## What Dataset Percentiles Define NeoVolta Inc: NV7600 {208V}?

Relative ranking of NeoVolta Inc: NV7600 {208V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

## What Do the Dataset Ranks Show for NeoVolta Inc: NV7600 {208V}?

Snapshot of NeoVolta Inc: NV7600 {208V} efficiency rank (#1,044), OCPD breaker size, MPPT span, and busbar verdict. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Eff #1,044 / 2,343

### 96.98% CEC Weighted Efficiency

+0.57 pts vs the 96.41% 208 V median; overall power rank #1,273 (7,447 W, below CEC median; higher than 45.7% of peers).

NEC 705.12 Check

### 45 A Required Backfeed OCPD

125% x 35.8 A = 44.8 A -> 45 A standard OCPD using 8 AWG Cu (75 C).

MPPT Window

### 240 V - 425 V (Max 425 V DC)

Tracking span of 185.0 V; listed since 2022-12-01 (hybrid battery-capable inverter).

Commercial / 3-Phase Fit

### PASS (120% Commercial Busbar)

Evaluated for 208 V, commercial single-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 7447.3W / 208 V -> 35.8 A | Breaker >= 1.25 * 35.8 = 44.8 A -> 45 A

CEC Inverters.csv for NeoVolta Inc: NV7600 {208V}: Paco=7447.3 W, Vac=208 V, Vdcmax=425.0 V, Eff=96.98%.

**Result:** Min 45 A breaker & 8 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).

## What Are the Published CEC Specifications for NeoVolta Inc: NV7600 {208V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for NeoVolta Inc: NV7600 {208V}. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Official California Energy Commission (NREL SAM) test parameters for NeoVolta Inc: NV7600 {208V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 7,447 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 208 V, commercial single-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 425 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 240 V - 425 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 20.7538 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 96.98% | Calculated AC/DC conversion ratio from CEC test protocol |
| **CEC Listing Date & Hybrid** | 2022-12-01 / Hybrid: Yes (Battery Capable) | Utility interconnection approval metadata |

## What Switchgear Limits Apply to NeoVolta Inc: NV7600 {208V} (208 V, commercial single-phase)?

NEC 705.12(B)(3)(2) backfeed compliance table for NeoVolta Inc: NV7600 {208V} at 208 V, commercial single-phase.

Evaluates NeoVolta Inc: NV7600 {208V} (45 A required OCPD at 208 V, commercial single-phase) across standard distribution busbars.

| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **200A Bus / 200A Main (208V)** | 40 A | 45 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **400A Bus / 400A Main (208V)** | 80 A | 45 A | PASS (120% Commercial Busbar) |
| **600A Bus / 600A Main (208V)** | 120 A | 45 A | PASS (120% Commercial Busbar) |
| **800A Bus / 800A Main (208V)** | 160 A | 45 A | PASS (120% Commercial Busbar) |
| **1,200A Bus / 1,200A Main (208V)** | 240 A | 45 A | PASS (120% Commercial Busbar) |

## Which CEC PV Module Strings Pair With NeoVolta Inc: NV7600 {208V}?

Minimum and maximum series solar module strings fitting NeoVolta Inc: NV7600 {208V} MPPT and 425 V limits. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Sampled CEC PV modules aligned within 240.0-425.0 V MPPT and 425.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 6 to 7 panels | 4.13 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 8 to 10 panels | 4.4 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 7 to 9 panels | 3.83 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 9 to 10 panels | 2.0 kW |

## Which Competing Grid-Support Inverters Compare to NeoVolta Inc: NV7600 {208V}?

Peer 208 V, commercial single-phase CEC inverters near 7,447 W AC output such as Chint Power Systems America: CPS ECH76KTL/US {208V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Chint Power Systems America: CPS ECH76KTL/US {208V}**](https://epri-peac.com/solar-equipment/inverters/chint-power-systems-america/chint-power-systems-america-cps-ech76ktl-us-208v/) Chint Power Systems America | 7,570 W | +123 W | 208.0 V | 480.0 V | 96.59% |
| [**ABB: UNO-76-TL-OUTD-S-US-A {208V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-uno-76-tl-outd-s-us-a-208v/) ABB | 7,600 W | +153 W | 208.0 V | 480.0 V | 96.6% |
| [**ABB: UNO-76-TL-OUTD-S-US-Z-A {208V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-uno-76-tl-outd-s-us-z-a-208v/) ABB | 7,600 W | +153 W | 208.0 V | 480.0 V | 96.6% |
| [**ABB: UNO-76-TL-OUTD-S-US-Z-M-A {208V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-uno-76-tl-outd-s-us-z-m-a-208v/) ABB | 7,600 W | +153 W | 208.0 V | 480.0 V | 96.6% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for NeoVolta Inc: NV7600 {208V}?

Check NeoVolta Inc: NV7600 {208V} (7,447 W AC, 45 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 208 V, commercial single-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 425 V DC on NeoVolta Inc: NV7600 {208V}.

### NeoVolta Inc: NV7600 {208V} Panel & Wire Spec

Size 75 C copper conductors at 8 AWG Cu on a 45 A OCPD breaker (35.8 A continuous).

### Alternative Inverter Comparison

Compare efficiency (96.98%) and MPPT window (240-425 V) directly against Chint Power Systems America: CPS ECH76KTL/US {208V} (7,570 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for NeoVolta Inc: NV7600 {208V} by NeoVolta Inc covering breaker sizing, MPPT limits, and 208 V, commercial single-phase interconnection.

### What breaker and wire size does NeoVolta Inc: NV7600 {208V} require?

At 7,447 W continuous AC (208 V, commercial single-phase), continuous current is 35.8 A; 125% NEC 690.8/705.12 sizing requires a 45 A breaker and 8 AWG Cu (75 C) wire.

### What commercial switchgear or feeder sizing does NeoVolta Inc: NV7600 {208V} require?

At 7,447 W AC and 208 V, commercial single-phase, continuous line current is 35.8 A, requiring a 45 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.

### How does NeoVolta Inc: NV7600 {208V} compare to Chint Power Systems America: CPS ECH76KTL/US {208V}?

NeoVolta Inc: NV7600 {208V} delivers 7,447 W AC at 96.98% CEC efficiency with a 425 V DC ceiling, while Chint Power Systems America: CPS ECH76KTL/US {208V} outputs 7,570 W at 208 V, commercial single-phase.

## Related Pages

Explore NeoVolta Inc hardware, Chint Power Systems America: CPS ECH76KTL/US {208V}, utility rates, and NEC 705.12 sizing calculators alongside NeoVolta Inc: NV7600 {208V}.

[All NeoVolta Inc Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/neovolta-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From NeoVolta Inc

- [All NeoVolta Inc Specs](https://epri-peac.com/solar-equipment/brands/neovolta-inc/)
- [NeoVolta Inc: NV16KAC {240V}](https://epri-peac.com/solar-equipment/inverters/neovolta-inc/neovolta-inc-nv16kac-240v/)
- [NeoVolta Inc: NV12KAC {240V}](https://epri-peac.com/solar-equipment/inverters/neovolta-inc/neovolta-inc-nv12kac-240v/)
- [NeoVolta Inc: NV7600 {240V}](https://epri-peac.com/solar-equipment/inverters/neovolta-inc/neovolta-inc-nv7600-240v/)