title: "Lion Energy: #50170167 Sanctuary Inverter (7,898W)"
url: https://epri-peac.com/solar-equipment/inverters/lion-energy/lion-energy-50170167-sanctuary-8k-240v/
description: "CEC specs for Lion Energy: #50170167 Sanctuary 8K {240V}: 7,898W AC, 240V, 45A OCPD, and NEC 705.12 checks. Verified US government and CEC engineering data."
---

CEC Grid-Support Inverter

# Lion Energy: #50170167 Sanctuary 8K {240V} — CEC Inverter Specifications

Manufacturer: [**Lion Energy**](https://epri-peac.com/solar-equipment/brands/lion-energy/) Registry: **CEC Verified Engineering Specification**

Lion Energy: #50170167 Sanctuary 8K {240V} outputs 7,898 W AC at 240 V (32.9 A continuous, 45 A OCPD), ranking #2,275 of 2,343 CEC inverters at 94.69% efficiency with a 240-425 V MPPT window and 425 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 7,898 W

- **AC Voltage** : 240 V

- **Min PV Breaker** : 45 A (8 AWG Cu)

- **CEC Efficiency** : 94.69%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Lion Energy: #50170167 Sanctuary 8K {240V} Compare Against Peer CEC Listings?

How Lion Energy Lion Energy: #50170167 Sanctuary 8K {240V} compares on 94.69% efficiency, MPPT span, and 120% busbar interconnection.

Lion Energy certifies Lion Energy: #50170167 Sanctuary 8K {240V} (hybrid battery-capable inverter, listed since 2023-04-03) at 7,898 W AC (2,122 W above the 5,776 W 240 V median). Its 425 V DC ceiling pairs with an MPPT window of 240-425 V (span 185.0 V). Under NEC 690.8/705.12, 125% sizing demands 8 AWG Cu conductors on a 45 A OCPD.

## Where Does Lion Energy: #50170167 Sanctuary 8K {240V} Fall Across Listed CEC Models?

Position of Lion Energy: #50170167 Sanctuary 8K {240V} (7,898 W AC) relative to the 7,680 W CEC median inverter.

## What Dataset Percentiles Define Lion Energy: #50170167 Sanctuary 8K {240V}?

Percentile placement of Lion Energy: #50170167 Sanctuary 8K {240V} across AC power class, conversion efficiency, and backfeed breaker size.

## What Do the Dataset Ranks Show for Lion Energy: #50170167 Sanctuary 8K {240V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for Lion Energy: #50170167 Sanctuary 8K {240V}.

Eff #2,275 / 2,343

### 94.69% CEC Weighted Efficiency

-1.99 pts vs the 96.68% 240 V median; overall power rank #1,134 (7,898 W, top 48.4%; higher than 51.6% of peers).

NEC 705.12 Check

### 45 A Required Backfeed OCPD

125% x 32.9 A = 41.1 A -> 45 A standard OCPD using 8 AWG Cu (75 C).

MPPT Window

### 240 V - 425 V (Max 425 V DC)

Tracking span of 185.0 V; listed since 2023-04-03 (hybrid battery-capable inverter).

Panel Fit (240V)

### Needs Derate / Tap 705.11

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 7898.0W / 240 V -> 32.9 A | Breaker >= 1.25 * 32.9 = 41.1 A -> 45 A

CEC Inverters.csv for Lion Energy: #50170167 Sanctuary 8K {240V}: Paco=7898.0 W, Vac=240 V, Vdcmax=425.0 V, Eff=94.69%.

**Result:** Min 45 A breaker & 8 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.

## What Are the Published CEC Specifications for Lion Energy: #50170167 Sanctuary 8K {240V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for Lion Energy: #50170167 Sanctuary 8K {240V}.

Official California Energy Commission (NREL SAM) test parameters for Lion Energy: #50170167 Sanctuary 8K {240V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 7,898 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 425 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 240 V - 425 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 22.5421 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 94.69% | Calculated AC/DC conversion ratio from CEC test protocol |
| **CEC Listing Date & Hybrid** | 2023-04-03 / Hybrid: Yes (Battery Capable) | Utility interconnection approval metadata |

## Can a Residential Panel Meet 120% Busbar Limits for Lion Energy: #50170167 Sanctuary 8K {240V}?

Check whether Lion Energy: #50170167 Sanctuary 8K {240V} (45 A breaker) fits without main breaker derate or supply-side taps.

Evaluates Lion Energy: #50170167 Sanctuary 8K {240V} (45 A required OCPD at 240 V) across standard distribution busbars.

| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **100A Bus / 100A Main** | 20 A | 45 A | Needs Derate / Tap 705.11 |
| **150A Bus / 150A Main** | 30 A | 45 A | Needs Derate / Tap 705.11 |
| **200A Bus / 200A Main** | 40 A | 45 A | Needs Derate / Tap 705.11 |
| **200A Bus / 175A Main** | 65 A | 45 A | PASS (120% Rule) |
| **225A Bus / 200A Main** | 70 A | 45 A | PASS (120% Rule) |

## Which CEC PV Module Strings Pair With Lion Energy: #50170167 Sanctuary 8K {240V}?

Verified cold-weather (-10 C) series module counts matched to Lion Energy: #50170167 Sanctuary 8K {240V}'s 425 V DC ceiling.

Sampled CEC PV modules aligned within 240.0-425.0 V MPPT and 425.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 6 to 7 panels | 4.13 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 8 to 10 panels | 4.4 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 7 to 9 panels | 3.83 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 9 to 10 panels | 2.0 kW |

## Which Competing Grid-Support Inverters Compare to Lion Energy: #50170167 Sanctuary 8K {240V}?

Alternative CEC inverters comparable to Lion Energy: #50170167 Sanctuary 8K {240V}, including Afore New Energy Technology (Shanghai) Co Ltd: AF8K-DH {240V} (7,999 W) at 240 V.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Afore New Energy Technology (Shanghai) Co Ltd: AF8K-DH {240V}**](https://epri-peac.com/solar-equipment/inverters/afore-new-energy-technology-shanghai-co-ltd/afore-new-energy-technology-shanghai-co-ltd-af8k-dh-240v/) Afore New Energy Technology (Shanghai) Co Ltd | 7,999 W | +101 W | 240.0 V | 480.0 V | 97.79% |
| [**Amensolar Ess Co Ltd: N3H-X76-US {240V}**](https://epri-peac.com/solar-equipment/inverters/amensolar-ess-co-ltd/amensolar-ess-co-ltd-n3h-x76-us-240v/) Amensolar Ess Co Ltd | 7,765 W | -133 W | 240.0 V | 430.0 V | 97.14% |
| [**Delta Electronics: E8 Plus-TL-US(AC) {240V}**](https://epri-peac.com/solar-equipment/inverters/delta-electronics/delta-electronics-e8-plus-tl-us-ac-240v/) Delta Electronics | 7,720 W | -178 W | 240.0 V | 480.0 V | 97.97% |
| [**Delta Electronics: E8_BDI {240V}**](https://epri-peac.com/solar-equipment/inverters/delta-electronics/delta-electronics-e8-bdi-240v/) Delta Electronics | 7,716 W | -182 W | 240.0 V | 480.0 V | 97.27% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Lion Energy: #50170167 Sanctuary 8K {240V}?

Check Lion Energy: #50170167 Sanctuary 8K {240V} (7,898 W AC, 45 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Its 45 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 425 V DC on Lion Energy: #50170167 Sanctuary 8K {240V}.

### Lion Energy: #50170167 Sanctuary 8K {240V} Panel & Wire Spec

Size 75 C copper conductors at 8 AWG Cu on a 45 A OCPD breaker (32.9 A continuous).

### Alternative Inverter Comparison

Compare efficiency (94.69%) and MPPT window (240-425 V) directly against Afore New Energy Technology (Shanghai) Co Ltd: AF8K-DH {240V} (7,999 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Lion Energy: #50170167 Sanctuary 8K {240V} by Lion Energy covering breaker sizing, MPPT limits, and 240 V interconnection.

### What breaker and wire size does Lion Energy: #50170167 Sanctuary 8K {240V} require?

At 7,898 W continuous AC (240 V), continuous current is 32.9 A; 125% NEC 690.8/705.12 sizing requires a 45 A breaker and 8 AWG Cu (75 C) wire.

### Does Lion Energy: #50170167 Sanctuary 8K {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 45 A at 240 V means Needs Derate / Tap 705.11.

### How does Lion Energy: #50170167 Sanctuary 8K {240V} compare to Afore New Energy Technology (Shanghai) Co Ltd: AF8K-DH {240V}?

Lion Energy: #50170167 Sanctuary 8K {240V} delivers 7,898 W AC at 94.69% CEC efficiency with a 425 V DC ceiling, while Afore New Energy Technology (Shanghai) Co Ltd: AF8K-DH {240V} outputs 7,999 W at 240 V.

## Related Pages

Explore Lion Energy hardware, Afore New Energy Technology (Shanghai) Co Ltd: AF8K-DH {240V}, utility rates, and NEC 705.12 sizing calculators alongside Lion Energy: #50170167 Sanctuary 8K {240V}.

[All Lion Energy Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/lion-energy/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Lion Energy

- [All Lion Energy Specs](https://epri-peac.com/solar-equipment/brands/lion-energy/)
- [Lion Energy: Sanctuary 3 Inverter 24kW {240V}](https://epri-peac.com/solar-equipment/inverters/lion-energy/lion-energy-sanctuary-3-inverter-24kw-240v/)
- [Lion Energy: Sanctuary 3 Inverter 18kW {240V}](https://epri-peac.com/solar-equipment/inverters/lion-energy/lion-energy-sanctuary-3-inverter-18kw-240v/)
- [Lion Energy: Lion Hybrid Inverter 15kW {240V}](https://epri-peac.com/solar-equipment/inverters/lion-energy/lion-energy-lion-hybrid-inverter-15kw-240v/)
- [Lion Energy: Sanctuary 3 Inverter 12kW {240V}](https://epri-peac.com/solar-equipment/inverters/lion-energy/lion-energy-sanctuary-3-inverter-12kw-240v/)
- [Lion Energy: #50170168 {240V}](https://epri-peac.com/solar-equipment/inverters/lion-energy/lion-energy-50170168-240v/)