title: "INGETEAM POWER TECHNOLOGY SA Inverter (2,306,000W)"
url: https://epri-peac.com/solar-equipment/inverters/ingeteam-power-technology-sa/ingeteam-power-technology-sa-ingecon-sun-storage-3660tl-u-c450-450v/
description: "CEC specs for INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C450 {450V}: 2,306,000W AC, 450V, 3700A OCPD, and NEC 705.12 checks."
---

CEC Grid-Support Inverter

# INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C450 {450V} — CEC Inverter Specifications

Manufacturer: [**INGETEAM POWER TECHNOLOGY SA**](https://epri-peac.com/solar-equipment/brands/ingeteam-power-technology-sa/) Registry: **CEC Verified Engineering Specification**

INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C450 {450V} outputs 2,306,000 W AC at 450 V, 3-phase (2958.7 A continuous, 3,700 A OCPD), ranking #1,571 of 2,343 CEC inverters at 96.49% efficiency with a 650-1,300 V MPPT window and 1,300 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 2,306,000 W

- **AC Voltage** : 450 V, 3-phase

- **Min PV Breaker** : 3,700 A (parallel Cu feeders)

- **CEC Efficiency** : 96.49%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C450 {450V} Compare Against Peer CEC Listings?

Breaker sizing (3,700 A), parallel Cu feeders wire rules, and DC input limits for INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C450 {450V}.

Classified as a grid-tied PV inverter (active in CEC directory), INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C450 {450V} requires 3698.4 A design capacity -> 3,700 A breaker using parallel Cu feeders copper at 75 C terminals. Weighted efficiency sits at 96.49% (-0.33 pts vs overall CEC median) across 2,343 CEC models, while commercial 450 v, 3-phase switchgear interconnection uses 1,200a bus / 1,200a main (450v) or nec 705.11 supply-side tap.

## Where Does INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C450 {450V} Fall Across Listed CEC Models?

Output power comparison showing where INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C450 {450V} sits among all 2,343 CEC-listed grid-support inverters.

## What Dataset Percentiles Define INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C450 {450V}?

Relative ranking of INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C450 {450V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

## What Do the Dataset Ranks Show for INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C450 {450V}?

Snapshot of INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C450 {450V} efficiency rank (#1,571), OCPD breaker size, MPPT span, and busbar verdict.

Eff #1,571 / 2,343

### 96.49% CEC Weighted Efficiency

-0.50 pts vs the 96.99% 450 V median; overall power rank #88 (2,306,000 W, top 3.8%; higher than 96.2% of peers).

NEC 705.12 Check

### 3,700 A Required Backfeed OCPD

125% x 2958.7 A = 3698.4 A -> 3,700 A standard OCPD using parallel Cu feeders (75 C).

MPPT Window

### 650 V - 1,300 V (Max 1,300 V DC)

Tracking span of 650.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

### Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 450 V, 3-phase switchgear (200A Bus / 200A Main (450V) to 1,200A Bus / 1,200A Main (450V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 2306000.0W / 450 V 3-phase -> 2958.7 A | Breaker >= 1.25 * 2958.7 = 3698.4 A -> 3,700 A

CEC Inverters.csv for INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C450 {450V}: Paco=2306000.0 W, Vac=450 V, Vdcmax=1300.0 V, Eff=96.49%.

**Result:** Min 3,700 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (450V): Supply-Side Tap (705.11) / Dedicated Switchboard.

## What Are the Published CEC Specifications for INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C450 {450V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C450 {450V}.

Official California Energy Commission (NREL SAM) test parameters for INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C450 {450V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 2,306,000 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 450 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 1,300 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 650 V - 1,300 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 2196.52 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 96.49% | Calculated AC/DC conversion ratio from CEC test protocol |
| **Inverter Topology** | Hybrid: No (Grid-Tied PV) | CEC Solar Equipment List grid-support certification |

## What Switchgear Limits Apply to INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C450 {450V} (450 V, 3-phase)?

NEC 705.12(B)(3)(2) backfeed compliance table for INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C450 {450V} at 450 V, 3-phase.

Evaluates INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C450 {450V} (3700 A required OCPD at 450 V, 3-phase) across standard distribution busbars.

| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **200A Bus / 200A Main (450V)** | 40 A | 3,700 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **400A Bus / 400A Main (450V)** | 80 A | 3,700 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **600A Bus / 600A Main (450V)** | 120 A | 3,700 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **800A Bus / 800A Main (450V)** | 160 A | 3,700 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **1,200A Bus / 1,200A Main (450V)** | 240 A | 3,700 A | Supply-Side Tap (705.11) / Dedicated Switchboard |

## Which CEC PV Module Strings Pair With INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C450 {450V}?

Minimum and maximum series solar module strings fitting INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C450 {450V} MPPT and 1,300 V limits.

Sampled CEC PV modules aligned within 650.0-1300.0 V MPPT and 1300.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 16 to 23 panels | 13.57 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 20 to 30 panels | 13.2 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 19 to 29 panels | 12.32 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 23 to 32 panels | 6.4 kW |

## Which Competing Grid-Support Inverters Compare to INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C450 {450V}?

Peer 450 V, 3-phase CEC inverters near 2,306,000 W AC output such as Power Electronics: FS2250CU15O3 {600V}. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Power Electronics: FS2250CU15O3 {600V}**](https://epri-peac.com/solar-equipment/inverters/power-electronics/power-electronics-fs2250cu15o3-600v/) Power Electronics | 2,420,370 W | +114370 W | 600.0 V | 1200.0 V | 97.82% |
| [**SINENG ELECTRIC CO LTD: EH-1725-HA-UD-US {690V}**](https://epri-peac.com/solar-equipment/inverters/sineng-electric-co-ltd/sineng-electric-co-ltd-eh-1725-ha-ud-us-690v/) SINENG ELECTRIC CO LTD | 1,726,700 W | -579300 W | 690.0 V | 1500.0 V | 98.32% |
| [**Schneider Electric USA Inc: CS1666-3-NA {575V}**](https://epri-peac.com/solar-equipment/inverters/schneider-electric-usa-inc/schneider-electric-usa-inc-cs1666-3-na-575v/) Schneider Electric USA Inc | 1,666,000 W | -640000 W | 575.0 V | 1200.0 V | 97.54% |
| [**Sungrow Power Supply Co Ltd: SG3150U {630V}**](https://epri-peac.com/solar-equipment/inverters/sungrow-power-supply-co-ltd/sungrow-power-supply-co-ltd-sg3150u-630v/) Sungrow Power Supply Co Ltd | 3,154,300 W | +848300 W | 630.0 V | 1300.0 V | 97.49% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C450 {450V}?

Check INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C450 {450V} (2,306,000 W AC, 3,700 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 450 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (450V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,300 V DC on INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C450 {450V}.

### INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C450 {450V} Panel & Wire Spec

Size 75 C copper conductors at parallel Cu feeders on a 3,700 A OCPD breaker (2958.7 A continuous).

### Alternative Inverter Comparison

Compare efficiency (96.49%) and MPPT window (650-1,300 V) directly against Power Electronics: FS2250CU15O3 {600V} (2,420,370 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C450 {450V} by INGETEAM POWER TECHNOLOGY SA covering breaker sizing, MPPT limits, and 450 V, 3-phase interconnection.

### What breaker and wire size does INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C450 {450V} require?

At 2,306,000 W continuous AC (450 V, 3-phase), continuous current is 2958.7 A; 125% NEC 690.8/705.12 sizing requires a 3,700 A breaker and parallel Cu feeders (75 C) wire.

### What commercial switchgear or feeder sizing does INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C450 {450V} require?

At 2,306,000 W AC and 450 V, 3-phase, continuous line current is 2958.7 A, requiring a 3,700 A OCPD and 1,200A Bus / 1,200A Main (450V) or NEC 705.11 interconnection.

### How does INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C450 {450V} compare to Power Electronics: FS2250CU15O3 {600V}?

INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C450 {450V} delivers 2,306,000 W AC at 96.49% CEC efficiency with a 1,300 V DC ceiling, while Power Electronics: FS2250CU15O3 {600V} outputs 2,420,370 W at 450 V, 3-phase.

## Related Pages

Explore INGETEAM POWER TECHNOLOGY SA hardware, Power Electronics: FS2250CU15O3 {600V}, utility rates, and NEC 705.12 sizing calculators alongside INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C450 {450V}.

[All INGETEAM POWER TECHNOLOGY SA Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/ingeteam-power-technology-sa/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From INGETEAM POWER TECHNOLOGY SA

- [All INGETEAM POWER TECHNOLOGY SA Specs](https://epri-peac.com/solar-equipment/brands/ingeteam-power-technology-sa/)
- [INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C690 {690V}](https://epri-peac.com/solar-equipment/inverters/ingeteam-power-technology-sa/ingeteam-power-technology-sa-ingecon-sun-3825tl-u-c690-690v/)
- [INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C690 {690V}](https://epri-peac.com/solar-equipment/inverters/ingeteam-power-technology-sa/ingeteam-power-technology-sa-ingecon-sun-storage-3660tl-u-c690-690v/)
- [INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C675 {675V}](https://epri-peac.com/solar-equipment/inverters/ingeteam-power-technology-sa/ingeteam-power-technology-sa-ingecon-sun-3825tl-u-c675-675v/)
- [INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C660 {660V}](https://epri-peac.com/solar-equipment/inverters/ingeteam-power-technology-sa/ingeteam-power-technology-sa-ingecon-sun-3825tl-u-c660-660v/)
- [INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C660 {660V}](https://epri-peac.com/solar-equipment/inverters/ingeteam-power-technology-sa/ingeteam-power-technology-sa-ingecon-sun-storage-3660tl-u-c660-660v/)