---
title: "INGETEAM POWER TECHNOLOGY SA Inverter (1,048,594W)"
url: https://epri-peac.com/solar-equipment/inverters/ingeteam-power-technology-sa/ingeteam-power-technology-sa-ingecon-sun-1190tl-u-b430-430v/
description: "CEC specs for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1190TL U B430 {430V}: 1,048,594W AC, 430V, 1800A OCPD, and NEC 705.12 checks."
---

CEC Grid-Support Inverter

# INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1190TL U B430 {430V} — CEC Inverter Specifications

Manufacturer: [**INGETEAM POWER TECHNOLOGY SA**](https://epri-peac.com/solar-equipment/brands/ingeteam-power-technology-sa/) Registry: **CEC Verified Engineering Specification**

INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1190TL U B430 {430V} outputs 1,048,594 W AC at 430 V, 3-phase (1408.0 A continuous, 1,800 A OCPD), ranking #595 of 2,343 CEC inverters at 97.41% efficiency with a 624-800 V MPPT window and 800 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 1,048,594 W

- **AC Voltage** : 430 V, 3-phase

- **Min PV Breaker** : 1,800 A (parallel Cu feeders)

- **CEC Efficiency** : 97.41%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1190TL U B430 {430V} Compare Against Peer CEC Listings?

CEC efficiency rank (#595), 624-800 V MPPT tracking, and panel fit for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1190TL U B430 {430V}.

Operating at 430 V, 3-phase, INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1190TL U B430 {430V} converts DC array energy at 97.41% CEC weighted efficiency (top 25.9%; higher than 74.1% of peers) with a 800 V max DC input and 1578.34 A max input current for NEC 690.7 string safety. Compare this 1,048,594 W hybrid battery-capable inverter directly with EPC Power Corp: 50-200100 {720V} (561,806 W). Commercial 430 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (430V) or NEC 705.11 supply-side tap.

## Where Does INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1190TL U B430 {430V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1190TL U B430 {430V} at 1,048,594 W continuous AC output.

## What Dataset Percentiles Define INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1190TL U B430 {430V}?

Dataset percentiles comparing INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1190TL U B430 {430V} against 2,343 certified grid-support inverters nationwide.

## What Do the Dataset Ranks Show for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1190TL U B430 {430V}?

Engineering highlights for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1190TL U B430 {430V} covering efficiency, parallel Cu feeders feeder, and panel compatibility.

Eff #595 / 2,343

### 97.41% CEC Weighted Efficiency

equal to the 97.41% 430 V median; overall power rank #161 (1,048,594 W, top 6.9%; higher than 93.1% of peers).

NEC 705.12 Check

### 1,800 A Required Backfeed OCPD

125% x 1408.0 A = 1760.0 A -> 1,800 A standard OCPD using parallel Cu feeders (75 C).

MPPT Window

### 624 V - 800 V (Max 800 V DC)

Tracking span of 176.0 V; active in CEC directory (hybrid battery-capable inverter).

Commercial / 3-Phase Fit

### Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 430 V, 3-phase switchgear (200A Bus / 200A Main (430V) to 1,200A Bus / 1,200A Main (430V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 1048594.0W / 430 V 3-phase -> 1408.0 A | Breaker >= 1.25 * 1408.0 = 1760.0 A -> 1,800 A

CEC Inverters.csv for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1190TL U B430 {430V}: Paco=1048594.0 W, Vac=430 V, Vdcmax=800.0 V, Eff=97.41%.

**Result:** Min 1,800 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (430V): Supply-Side Tap (705.11) / Dedicated Switchboard.

## What Are the Published CEC Specifications for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1190TL U B430 {430V}?

California Energy Commission Solar Equipment List parameters for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1190TL U B430 {430V} (hybrid battery-capable inverter) interconnection.

Official California Energy Commission (NREL SAM) test parameters for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1190TL U B430 {430V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 1,048,594 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 430 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 800 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 624 V - 800 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 1578.34 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 97.41% | Calculated AC/DC conversion ratio from CEC test protocol |
| **Inverter Topology** | Hybrid: Yes (Battery Capable) | CEC Solar Equipment List grid-support certification |

## What Switchgear Limits Apply to INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1190TL U B430 {430V} (430 V, 3-phase)?

Panelboard and switchgear backfeed allowances for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1190TL U B430 {430V} (1,800 A OCPD).

Evaluates INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1190TL U B430 {430V} (1800 A required OCPD at 430 V, 3-phase) across standard distribution busbars.

| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **200A Bus / 200A Main (430V)** | 40 A | 1,800 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **400A Bus / 400A Main (430V)** | 80 A | 1,800 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **600A Bus / 600A Main (430V)** | 120 A | 1,800 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **800A Bus / 800A Main (430V)** | 160 A | 1,800 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **1,200A Bus / 1,200A Main (430V)** | 240 A | 1,800 A | Supply-Side Tap (705.11) / Dedicated Switchboard |

## Which Competing Grid-Support Inverters Compare to INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1190TL U B430 {430V}?

Four alternative CEC inverters matched to INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1190TL U B430 {430V} (1,048,594 W AC), led by EPC Power Corp: 50-200100 {720V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**EPC Power Corp: 50-200100 {720V}**](https://epri-peac.com/solar-equipment/inverters/epc-power-corp/epc-power-corp-50-200100-720v/) EPC Power Corp | 561,806 W | -486788 W | 720.0 V | 1500.0 V | 98.58% |
| [**Schneider Electric USA Inc: CS1666-3-NA {575V}**](https://epri-peac.com/solar-equipment/inverters/schneider-electric-usa-inc/schneider-electric-usa-inc-cs1666-3-na-575v/) Schneider Electric USA Inc | 1,666,000 W | +617406 W | 575.0 V | 1200.0 V | 97.54% |
| [**SINENG ELECTRIC CO LTD: EH-1725-HA-UD-US {690V}**](https://epri-peac.com/solar-equipment/inverters/sineng-electric-co-ltd/sineng-electric-co-ltd-eh-1725-ha-ud-us-690v/) SINENG ELECTRIC CO LTD | 1,726,700 W | +678106 W | 690.0 V | 1500.0 V | 98.32% |
| [**ABB: PVS-175-TL-POWER-MODULE-1-US {800V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-pvs-175-tl-power-module-1-us-800v/) ABB | 179,574 W | -869020 W | 800.0 V | 1200.0 V | 97.39% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1190TL U B430 {430V}?

Check INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1190TL U B430 {430V} (1,048,594 W AC, 1,800 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 430 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (430V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 800 V DC on INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1190TL U B430 {430V}.

### INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1190TL U B430 {430V} Panel & Wire Spec

Size 75 C copper conductors at parallel Cu feeders on a 1,800 A OCPD breaker (1408.0 A continuous).

### Alternative Inverter Comparison

Compare efficiency (97.41%) and MPPT window (624-800 V) directly against EPC Power Corp: 50-200100 {720V} (561,806 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1190TL U B430 {430V} by INGETEAM POWER TECHNOLOGY SA covering breaker sizing, MPPT limits, and 430 V, 3-phase interconnection.

### What breaker and wire size does INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1190TL U B430 {430V} require?

At 1,048,594 W continuous AC (430 V, 3-phase), continuous current is 1408.0 A; 125% NEC 690.8/705.12 sizing requires a 1,800 A breaker and parallel Cu feeders (75 C) wire.

### What commercial switchgear or feeder sizing does INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1190TL U B430 {430V} require?

At 1,048,594 W AC and 430 V, 3-phase, continuous line current is 1408.0 A, requiring a 1,800 A OCPD and 1,200A Bus / 1,200A Main (430V) or NEC 705.11 interconnection.

### How does INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1190TL U B430 {430V} compare to EPC Power Corp: 50-200100 {720V}?

INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1190TL U B430 {430V} delivers 1,048,594 W AC at 97.41% CEC efficiency with a 800 V DC ceiling, while EPC Power Corp: 50-200100 {720V} outputs 561,806 W at 430 V, 3-phase.

## Related Pages

Explore INGETEAM POWER TECHNOLOGY SA hardware, EPC Power Corp: 50-200100 {720V}, utility rates, and NEC 705.12 sizing calculators alongside INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1190TL U B430 {430V}.

[All INGETEAM POWER TECHNOLOGY SA Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/ingeteam-power-technology-sa/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From INGETEAM POWER TECHNOLOGY SA

- [All INGETEAM POWER TECHNOLOGY SA Specs](https://epri-peac.com/solar-equipment/brands/ingeteam-power-technology-sa/)
- [INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C690 {690V}](https://epri-peac.com/solar-equipment/inverters/ingeteam-power-technology-sa/ingeteam-power-technology-sa-ingecon-sun-3825tl-u-c690-690v/)
- [INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C690 {690V}](https://epri-peac.com/solar-equipment/inverters/ingeteam-power-technology-sa/ingeteam-power-technology-sa-ingecon-sun-storage-3660tl-u-c690-690v/)
- [INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C675 {675V}](https://epri-peac.com/solar-equipment/inverters/ingeteam-power-technology-sa/ingeteam-power-technology-sa-ingecon-sun-3825tl-u-c675-675v/)
- [INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C660 {660V}](https://epri-peac.com/solar-equipment/inverters/ingeteam-power-technology-sa/ingeteam-power-technology-sa-ingecon-sun-3825tl-u-c660-660v/)
- [INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C660 {660V}](https://epri-peac.com/solar-equipment/inverters/ingeteam-power-technology-sa/ingeteam-power-technology-sa-ingecon-sun-storage-3660tl-u-c660-660v/)
