title: "INGETEAM POWER TECHNOLOGY SA Inverter (1,027,752W)"
url: https://epri-peac.com/solar-equipment/inverters/ingeteam-power-technology-sa/ingeteam-power-technology-sa-ingecon-sun-1140tl-u-b410-410v/
description: "CEC specs for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V}: 1,027,752W AC, 410V, 1850A OCPD, and NEC 705.12 checks."
---

CEC Grid-Support Inverter

# INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V} — CEC Inverter Specifications

Manufacturer: [**INGETEAM POWER TECHNOLOGY SA**](https://epri-peac.com/solar-equipment/brands/ingeteam-power-technology-sa/) Registry: **CEC Verified Engineering Specification**

INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V} outputs 1,027,752 W AC at 410 V, 3-phase (1447.3 A continuous, 1,850 A OCPD), ranking #654 of 2,343 CEC inverters at 97.35% efficiency with a 595-800 V MPPT window and 800 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 1,027,752 W

- **AC Voltage** : 410 V, 3-phase

- **Min PV Breaker** : 1,850 A (parallel Cu feeders)

- **CEC Efficiency** : 97.35%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V} Compare Against Peer CEC Listings?

Breaker sizing (1,850 A), parallel Cu feeders wire rules, and DC input limits for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V}.

For NEC 705.12 solar interconnection, INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V} outputs 1447.3 A continuous AC at 410 V, 3-phase and needs a 1,850 A backfeed breaker on parallel Cu feeders (75 C). Commercial 410 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (410V) or NEC 705.11 supply-side tap. Conversion efficiency scores 97.35% (#654 of 2,343, +0.53 pts vs overall CEC median).

## Where Does INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V} Fall Across Listed CEC Models?

Output power comparison showing where INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V} sits among all 2,343 CEC-listed grid-support inverters.

## What Dataset Percentiles Define INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V}?

Relative ranking of INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

## What Do the Dataset Ranks Show for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V}?

Snapshot of INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V} efficiency rank (#654), OCPD breaker size, MPPT span, and busbar verdict.

Eff #654 / 2,343

### 97.35% CEC Weighted Efficiency

equal to the 97.35% 410 V median; overall power rank #165 (1,027,752 W, top 7.0%; higher than 93.0% of peers).

NEC 705.12 Check

### 1,850 A Required Backfeed OCPD

125% x 1447.3 A = 1809.1 A -> 1,850 A standard OCPD using parallel Cu feeders (75 C).

MPPT Window

### 595 V - 800 V (Max 800 V DC)

Tracking span of 205.0 V; active in CEC directory (hybrid battery-capable inverter).

Commercial / 3-Phase Fit

### Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 410 V, 3-phase switchgear (200A Bus / 200A Main (410V) to 1,200A Bus / 1,200A Main (410V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 1027752.0W / 410 V 3-phase -> 1447.3 A | Breaker >= 1.25 * 1447.3 = 1809.1 A -> 1,850 A

CEC Inverters.csv for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V}: Paco=1027752.0 W, Vac=410 V, Vdcmax=800.0 V, Eff=97.35%.

**Result:** Min 1,850 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (410V): Supply-Side Tap (705.11) / Dedicated Switchboard.

## What Are the Published CEC Specifications for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V}.

Official California Energy Commission (NREL SAM) test parameters for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 1,027,752 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 410 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 800 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 595 V - 800 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 1580.48 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 97.35% | Calculated AC/DC conversion ratio from CEC test protocol |
| **Inverter Topology** | Hybrid: Yes (Battery Capable) | CEC Solar Equipment List grid-support certification |

## What Switchgear Limits Apply to INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V} (410 V, 3-phase)?

NEC 705.12(B)(3)(2) backfeed compliance table for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V} at 410 V, 3-phase.

Evaluates INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V} (1850 A required OCPD at 410 V, 3-phase) across standard distribution busbars.

| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **200A Bus / 200A Main (410V)** | 40 A | 1,850 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **400A Bus / 400A Main (410V)** | 80 A | 1,850 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **600A Bus / 600A Main (410V)** | 120 A | 1,850 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **800A Bus / 800A Main (410V)** | 160 A | 1,850 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **1,200A Bus / 1,200A Main (410V)** | 240 A | 1,850 A | Supply-Side Tap (705.11) / Dedicated Switchboard |

## Which CEC PV Module Strings Pair With INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V}?

Minimum and maximum series solar module strings fitting INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V} MPPT and 800 V limits.

Sampled CEC PV modules aligned within 595.0-800.0 V MPPT and 800.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 14 panels (fixed) | 8.26 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 18 panels (fixed) | 7.92 kW |
| [**Hansol Technics Co Ltd HA650-AE-NNEA0**](https://epri-peac.com/solar-equipment/modules/hansol-technics-co-ltd/hansol-technics-co-ltd-ha650-ae-nnea0/) | 650.0 W | 61.2 V | 13 panels (fixed) | 8.45 kW |
| [**Hyperion Solar HY-DH132P8-480**](https://epri-peac.com/solar-equipment/modules/hyperion-solar/hyperion-solar-hy-dh132p8-480/) | 480.0 W | 49.91 V | 16 panels (fixed) | 7.68 kW |

## Which Competing Grid-Support Inverters Compare to INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V}?

Peer 410 V, 3-phase CEC inverters near 1,027,752 W AC output such as EPC Power Corp: 50-200100 {720V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**EPC Power Corp: 50-200100 {720V}**](https://epri-peac.com/solar-equipment/inverters/epc-power-corp/epc-power-corp-50-200100-720v/) EPC Power Corp | 561,806 W | -465946 W | 720.0 V | 1500.0 V | 98.58% |
| [**Schneider Electric USA Inc: CS1666-3-NA {575V}**](https://epri-peac.com/solar-equipment/inverters/schneider-electric-usa-inc/schneider-electric-usa-inc-cs1666-3-na-575v/) Schneider Electric USA Inc | 1,666,000 W | +638248 W | 575.0 V | 1200.0 V | 97.54% |
| [**SINENG ELECTRIC CO LTD: EH-1725-HA-UD-US {690V}**](https://epri-peac.com/solar-equipment/inverters/sineng-electric-co-ltd/sineng-electric-co-ltd-eh-1725-ha-ud-us-690v/) SINENG ELECTRIC CO LTD | 1,726,700 W | +698948 W | 690.0 V | 1500.0 V | 98.32% |
| [**ABB: PVS-175-TL-POWER-MODULE-1-US {800V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-pvs-175-tl-power-module-1-us-800v/) ABB | 179,574 W | -848178 W | 800.0 V | 1200.0 V | 97.39% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V}?

Check INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V} (1,027,752 W AC, 1,850 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 410 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (410V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 800 V DC on INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V}.

### INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V} Panel & Wire Spec

Size 75 C copper conductors at parallel Cu feeders on a 1,850 A OCPD breaker (1447.3 A continuous).

### Alternative Inverter Comparison

Compare efficiency (97.35%) and MPPT window (595-800 V) directly against EPC Power Corp: 50-200100 {720V} (561,806 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V} by INGETEAM POWER TECHNOLOGY SA covering breaker sizing, MPPT limits, and 410 V, 3-phase interconnection.

### What breaker and wire size does INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V} require?

At 1,027,752 W continuous AC (410 V, 3-phase), continuous current is 1447.3 A; 125% NEC 690.8/705.12 sizing requires a 1,850 A breaker and parallel Cu feeders (75 C) wire.

### What commercial switchgear or feeder sizing does INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V} require?

At 1,027,752 W AC and 410 V, 3-phase, continuous line current is 1447.3 A, requiring a 1,850 A OCPD and 1,200A Bus / 1,200A Main (410V) or NEC 705.11 interconnection.

### How does INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V} compare to EPC Power Corp: 50-200100 {720V}?

INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V} delivers 1,027,752 W AC at 97.35% CEC efficiency with a 800 V DC ceiling, while EPC Power Corp: 50-200100 {720V} outputs 561,806 W at 410 V, 3-phase.

## Related Pages

Explore INGETEAM POWER TECHNOLOGY SA hardware, EPC Power Corp: 50-200100 {720V}, utility rates, and NEC 705.12 sizing calculators alongside INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V}.

[All INGETEAM POWER TECHNOLOGY SA Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/ingeteam-power-technology-sa/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From INGETEAM POWER TECHNOLOGY SA

- [All INGETEAM POWER TECHNOLOGY SA Specs](https://epri-peac.com/solar-equipment/brands/ingeteam-power-technology-sa/)
- [INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C690 {690V}](https://epri-peac.com/solar-equipment/inverters/ingeteam-power-technology-sa/ingeteam-power-technology-sa-ingecon-sun-3825tl-u-c690-690v/)
- [INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C690 {690V}](https://epri-peac.com/solar-equipment/inverters/ingeteam-power-technology-sa/ingeteam-power-technology-sa-ingecon-sun-storage-3660tl-u-c690-690v/)
- [INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C675 {675V}](https://epri-peac.com/solar-equipment/inverters/ingeteam-power-technology-sa/ingeteam-power-technology-sa-ingecon-sun-3825tl-u-c675-675v/)
- [INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C660 {660V}](https://epri-peac.com/solar-equipment/inverters/ingeteam-power-technology-sa/ingeteam-power-technology-sa-ingecon-sun-3825tl-u-c660-660v/)
- [INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C660 {660V}](https://epri-peac.com/solar-equipment/inverters/ingeteam-power-technology-sa/ingeteam-power-technology-sa-ingecon-sun-storage-3660tl-u-c660-660v/)