title: "Hyperian Energy Inc: ST2-120i Inverter (11,968W)"
url: https://epri-peac.com/solar-equipment/inverters/hyperian-energy-inc/hyperian-energy-inc-st2-120i-240v/
description: "CEC specs for Hyperian Energy Inc: ST2-120i {240V}: 11,968W AC, 240V, 70A OCPD, and NEC 705.12 checks. Verified US government and CEC engineering data."
---

CEC Grid-Support Inverter

# Hyperian Energy Inc: ST2-120i {240V} — CEC Inverter Specifications

Manufacturer: [**Hyperian Energy Inc**](https://epri-peac.com/solar-equipment/brands/hyperian-energy-inc/) Registry: **CEC Verified Engineering Specification**

Hyperian Energy Inc: ST2-120i {240V} outputs 11,968 W AC at 240 V (49.9 A continuous, 70 A OCPD), ranking #946 of 2,343 CEC inverters at 97.04% efficiency with a 300-440 V MPPT window and 440 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 11,968 W

- **AC Voltage** : 240 V

- **Min PV Breaker** : 70 A (4 AWG Cu)

- **CEC Efficiency** : 97.04%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Hyperian Energy Inc: ST2-120i {240V} Compare Against Peer CEC Listings?

Breaker sizing (70 A), 4 AWG Cu wire rules, and DC input limits for Hyperian Energy Inc: ST2-120i {240V}.

Classified as a hybrid battery-capable inverter (active in CEC directory), Hyperian Energy Inc: ST2-120i {240V} requires 62.4 A design capacity -> 70 A breaker using 4 AWG Cu copper at 75 C terminals. Weighted efficiency sits at 97.04% (+0.22 pts vs overall CEC median) across 2,343 CEC models, while its 70 a backfeed breaker exceeds a 200a/200a panel's 40 a ceiling, requiring a 175 a main derate, 225 a busbar, or nec 705.11 tap.

## Where Does Hyperian Energy Inc: ST2-120i {240V} Fall Across Listed CEC Models?

Output power comparison showing where Hyperian Energy Inc: ST2-120i {240V} sits among all 2,343 CEC-listed grid-support inverters. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

## What Dataset Percentiles Define Hyperian Energy Inc: ST2-120i {240V}?

Relative ranking of Hyperian Energy Inc: ST2-120i {240V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

## What Do the Dataset Ranks Show for Hyperian Energy Inc: ST2-120i {240V}?

Snapshot of Hyperian Energy Inc: ST2-120i {240V} efficiency rank (#946), OCPD breaker size, MPPT span, and busbar verdict.

Eff #946 / 2,343

### 97.04% CEC Weighted Efficiency

+0.36 pts vs the 96.68% 240 V median; overall power rank #740 (11,968 W, top 31.6%; higher than 68.4% of peers).

NEC 705.12 Check

### 70 A Required Backfeed OCPD

125% x 49.9 A = 62.4 A -> 70 A standard OCPD using 4 AWG Cu (75 C).

MPPT Window

### 300 V - 440 V (Max 440 V DC)

Tracking span of 140.0 V; active in CEC directory (hybrid battery-capable inverter).

Panel Fit (240V)

### Needs Derate / Tap 705.11

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 11968.0W / 240 V -> 49.9 A | Breaker >= 1.25 * 49.9 = 62.4 A -> 70 A

CEC Inverters.csv for Hyperian Energy Inc: ST2-120i {240V}: Paco=11968.0 W, Vac=240 V, Vdcmax=440.0 V, Eff=97.04%.

**Result:** Min 70 A breaker & 4 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.

## What Are the Published CEC Specifications for Hyperian Energy Inc: ST2-120i {240V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Hyperian Energy Inc: ST2-120i {240V}. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Official California Energy Commission (NREL SAM) test parameters for Hyperian Energy Inc: ST2-120i {240V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 11,968 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 440 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 300 V - 440 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 33.3322 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 97.04% | Calculated AC/DC conversion ratio from CEC test protocol |
| **Inverter Topology** | Hybrid: Yes (Battery Capable) | CEC Solar Equipment List grid-support certification |

## Can a Residential Panel Meet 120% Busbar Limits for Hyperian Energy Inc: ST2-120i {240V}?

NEC 705.12(B)(3)(2) backfeed compliance table for Hyperian Energy Inc: ST2-120i {240V} at 240 V. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Evaluates Hyperian Energy Inc: ST2-120i {240V} (70 A required OCPD at 240 V) across standard distribution busbars.

| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **100A Bus / 100A Main** | 20 A | 70 A | Needs Derate / Tap 705.11 |
| **150A Bus / 150A Main** | 30 A | 70 A | Needs Derate / Tap 705.11 |
| **200A Bus / 200A Main** | 40 A | 70 A | Needs Derate / Tap 705.11 |
| **200A Bus / 175A Main** | 65 A | 70 A | Needs Derate / Tap 705.11 |
| **225A Bus / 200A Main** | 70 A | 70 A | PASS (120% Rule) |

## Which CEC PV Module Strings Pair With Hyperian Energy Inc: ST2-120i {240V}?

Minimum and maximum series solar module strings fitting Hyperian Energy Inc: ST2-120i {240V} MPPT and 440 V limits.

Sampled CEC PV modules aligned within 300.0-440.0 V MPPT and 440.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 7 panels (fixed) | 4.13 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 9 to 10 panels | 4.4 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 9 panels (fixed) | 3.83 kW |
| [**Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-515**](https://epri-peac.com/solar-equipment/modules/chint-new-energy-technology-co-ltd/chint-new-energy-technology-co-ltd-chsm72m-dg-f-bh-515/) | 515.0 W | 53.76 V | 8 panels (fixed) | 4.12 kW |

## Which Competing Grid-Support Inverters Compare to Hyperian Energy Inc: ST2-120i {240V}?

Peer 240 V CEC inverters near 11,968 W AC output such as Chint Power Systems America: CPS ECH12KTL/US {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Chint Power Systems America: CPS ECH12KTL/US {240V}**](https://epri-peac.com/solar-equipment/inverters/chint-power-systems-america/chint-power-systems-america-cps-ech12ktl-us-240v/) Chint Power Systems America | 11,990 W | +22 W | 240.0 V | 480.0 V | 96.59% |
| [**Amensolar Ess Co Ltd: N3H-X12US {240V}**](https://epri-peac.com/solar-equipment/inverters/amensolar-ess-co-ltd/amensolar-ess-co-ltd-n3h-x12us-240v/) Amensolar Ess Co Ltd | 12,214 W | +246 W | 240.0 V | 430.0 V | 96.17% |
| [**Delta Electronics: S12_BDI {240V}**](https://epri-peac.com/solar-equipment/inverters/delta-electronics/delta-electronics-s12-bdi-240v/) Delta Electronics | 11,589 W | -379 W | 240.0 V | 480.0 V | 96.99% |
| [**Base Power Inc: MIN 11400TL-XH-US {240V}**](https://epri-peac.com/solar-equipment/inverters/base-power-inc/base-power-inc-min-11400tl-xh-us-240v/) Base Power Inc | 11,520 W | -448 W | 240.0 V | 480.0 V | 97.76% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Hyperian Energy Inc: ST2-120i {240V}?

Check Hyperian Energy Inc: ST2-120i {240V} (11,968 W AC, 70 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Its 70 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 440 V DC on Hyperian Energy Inc: ST2-120i {240V}.

### Hyperian Energy Inc: ST2-120i {240V} Panel & Wire Spec

Size 75 C copper conductors at 4 AWG Cu on a 70 A OCPD breaker (49.9 A continuous).

### Alternative Inverter Comparison

Compare efficiency (97.04%) and MPPT window (300-440 V) directly against Chint Power Systems America: CPS ECH12KTL/US {240V} (11,990 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Hyperian Energy Inc: ST2-120i {240V} by Hyperian Energy Inc covering breaker sizing, MPPT limits, and 240 V interconnection.

### What breaker and wire size does Hyperian Energy Inc: ST2-120i {240V} require?

At 11,968 W continuous AC (240 V), continuous current is 49.9 A; 125% NEC 690.8/705.12 sizing requires a 70 A breaker and 4 AWG Cu (75 C) wire.

### Does Hyperian Energy Inc: ST2-120i {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 70 A at 240 V means Needs Derate / Tap 705.11.

### How does Hyperian Energy Inc: ST2-120i {240V} compare to Chint Power Systems America: CPS ECH12KTL/US {240V}?

Hyperian Energy Inc: ST2-120i {240V} delivers 11,968 W AC at 97.04% CEC efficiency with a 440 V DC ceiling, while Chint Power Systems America: CPS ECH12KTL/US {240V} outputs 11,990 W at 240 V.

## Related Pages

Explore Hyperian Energy Inc hardware, Chint Power Systems America: CPS ECH12KTL/US {240V}, utility rates, and NEC 705.12 sizing calculators alongside Hyperian Energy Inc: ST2-120i {240V}.

[All Hyperian Energy Inc Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/hyperian-energy-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Hyperian Energy Inc

- [All Hyperian Energy Inc Specs](https://epri-peac.com/solar-equipment/brands/hyperian-energy-inc/)
- [Hyperian Energy Inc: ST2-114i {240V}](https://epri-peac.com/solar-equipment/inverters/hyperian-energy-inc/hyperian-energy-inc-st2-114i-240v/)
- [Hyperian Energy Inc: ST2-100i {240V}](https://epri-peac.com/solar-equipment/inverters/hyperian-energy-inc/hyperian-energy-inc-st2-100i-240v/)
- [Hyperian Energy Inc: ST2-96i {240V}](https://epri-peac.com/solar-equipment/inverters/hyperian-energy-inc/hyperian-energy-inc-st2-96i-240v/)
- [Hyperian Energy Inc: ST2-76i {240V}](https://epri-peac.com/solar-equipment/inverters/hyperian-energy-inc/hyperian-energy-inc-st2-76i-240v/)