# Huawei Technologies Co Ltd: SUN2000-38KTL-USL0 {240V} — CEC Inverter Specifications

Manufacturer: [**Huawei Technologies Co Ltd**](https://epri-peac.com/solar-equipment/brands/huawei-technologies-co-ltd/) Registry: **CEC Verified Engineering Specification**

Huawei Technologies Co Ltd: SUN2000-38KTL-USL0 {240V} outputs 3,800 W AC at 240 V (15.8 A continuous, 20 A OCPD), ranking #3 of 2,343 CEC inverters at 99.03% efficiency with a 370-420 V MPPT window and 420 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 3,800 W

- **AC Voltage** : 240 V

- **Min PV Breaker** : 20 A (12 AWG Cu)

- **CEC Efficiency** : 99.03%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Huawei Technologies Co Ltd: SUN2000-38KTL-USL0 {240V} Compare Against Peer CEC Listings?

Breaker sizing (20 A), 12 AWG Cu wire rules, and DC input limits for Huawei Technologies Co Ltd: SUN2000-38KTL-USL0 {240V}.

Classified as a grid-tied PV inverter (listed since 2019-01-15), Huawei Technologies Co Ltd: SUN2000-38KTL-USL0 {240V} requires 19.8 A design capacity -> 20 A breaker using 12 AWG Cu copper at 75 C terminals. Weighted efficiency sits at 99.03% (+2.21 pts vs overall CEC median) across 2,343 CEC models, while requires a 20 a breaker, passing directly inside a standard 200 a main / 200 a busbar panel (40 a limit).

## Where Does Huawei Technologies Co Ltd: SUN2000-38KTL-USL0 {240V} Fall Across Listed CEC Models?

Output power comparison showing where Huawei Technologies Co Ltd: SUN2000-38KTL-USL0 {240V} sits among all 2,343 CEC-listed grid-support inverters.

## What Dataset Percentiles Define Huawei Technologies Co Ltd: SUN2000-38KTL-USL0 {240V}?

Relative ranking of Huawei Technologies Co Ltd: SUN2000-38KTL-USL0 {240V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

## What Do the Dataset Ranks Show for Huawei Technologies Co Ltd: SUN2000-38KTL-USL0 {240V}?

Snapshot of Huawei Technologies Co Ltd: SUN2000-38KTL-USL0 {240V} efficiency rank (#3), OCPD breaker size, MPPT span, and busbar verdict.

Eff #3 / 2,343

### 99.03% CEC Weighted Efficiency

+2.35 pts vs the 96.68% 240 V median; overall power rank #1,650 (3,800 W, below CEC median; higher than 28.7% of peers).

NEC 705.12 Check

### 20 A Required Backfeed OCPD

125% x 15.8 A = 19.8 A -> 20 A standard OCPD using 12 AWG Cu (75 C).

MPPT Window

### 370 V - 420 V (Max 420 V DC)

Tracking span of 50.0 V; listed since 2019-01-15 (grid-tied PV inverter).

Panel Fit (240V)

### PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 3800.0W / 240 V -> 15.8 A | Breaker >= 1.25 * 15.8 = 19.8 A -> 20 A

CEC Inverters.csv for Huawei Technologies Co Ltd: SUN2000-38KTL-USL0 {240V}: Paco=3800.0 W, Vac=240 V, Vdcmax=420.0 V, Eff=99.03%.

**Result:** Min 20 A breaker & 12 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

## What Are the Published CEC Specifications for Huawei Technologies Co Ltd: SUN2000-38KTL-USL0 {240V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Huawei Technologies Co Ltd: SUN2000-38KTL-USL0 {240V}.

Official California Energy Commission (NREL SAM) test parameters for Huawei Technologies Co Ltd: SUN2000-38KTL-USL0 {240V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 3,800 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 420 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 370 V - 420 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 9.71431 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 99.03% | Calculated AC/DC conversion ratio from CEC test protocol |
| **CEC Listing Date & Hybrid** | 2019-01-15 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |

## Can a Residential Panel Meet 120% Busbar Limits for Huawei Technologies Co Ltd: SUN2000-38KTL-USL0 {240V}?

NEC 705.12(B)(3)(2) backfeed compliance table for Huawei Technologies Co Ltd: SUN2000-38KTL-USL0 {240V} at 240 V.

Evaluates Huawei Technologies Co Ltd: SUN2000-38KTL-USL0 {240V} (20 A required OCPD at 240 V) across standard distribution busbars.

| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **100A Bus / 100A Main** | 20 A | 20 A | PASS (120% Rule) |
| **150A Bus / 150A Main** | 30 A | 20 A | PASS (120% Rule) |
| **200A Bus / 200A Main** | 40 A | 20 A | PASS (120% Rule) |
| **200A Bus / 175A Main** | 65 A | 20 A | PASS (120% Rule) |
| **225A Bus / 200A Main** | 70 A | 20 A | PASS (120% Rule) |

## Which Competing Grid-Support Inverters Compare to Huawei Technologies Co Ltd: SUN2000-38KTL-USL0 {240V}?

Peer 240 V CEC inverters near 3,800 W AC output such as ABB: PVI-38-OUTD-S-US-A {240V}. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**ABB: PVI-38-OUTD-S-US-A {240V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-pvi-38-outd-s-us-a-240v/) ABB | 3,800 W | Tie (0 W) | 240.0 V | 480.0 V | 96.2% |
| [**ABB: PVI-38-OUTD-S-US-Z-A {240V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-pvi-38-outd-s-us-z-a-240v/) ABB | 3,800 W | Tie (0 W) | 240.0 V | 480.0 V | 96.2% |
| [**ABB: PVI-38-OUTD-S-US-Z-M-A {240V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-pvi-38-outd-s-us-z-m-a-240v/) ABB | 3,800 W | Tie (0 W) | 240.0 V | 480.0 V | 96.2% |
| [**ABB: UNO-DM-38-TL-PLUS-US-SB-RA {240V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-uno-dm-38-tl-plus-us-sb-ra-240v/) ABB | 3,800 W | Tie (0 W) | 240.0 V | 480.0 V | 96.39% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Huawei Technologies Co Ltd: SUN2000-38KTL-USL0 {240V}?

Check Huawei Technologies Co Ltd: SUN2000-38KTL-USL0 {240V} (3,800 W AC, 20 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Requires a 20 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 420 V DC on Huawei Technologies Co Ltd: SUN2000-38KTL-USL0 {240V}.

### Huawei Technologies Co Ltd: SUN2000-38KTL-USL0 {240V} Panel & Wire Spec

Size 75 C copper conductors at 12 AWG Cu on a 20 A OCPD breaker (15.8 A continuous).

### Alternative Inverter Comparison

Compare efficiency (99.03%) and MPPT window (370-420 V) directly against ABB: PVI-38-OUTD-S-US-A {240V} (3,800 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Huawei Technologies Co Ltd: SUN2000-38KTL-USL0 {240V} by Huawei Technologies Co Ltd covering breaker sizing, MPPT limits, and 240 V interconnection.

### What breaker and wire size does Huawei Technologies Co Ltd: SUN2000-38KTL-USL0 {240V} require?

At 3,800 W continuous AC (240 V), continuous current is 15.8 A; 125% NEC 690.8/705.12 sizing requires a 20 A breaker and 12 AWG Cu (75 C) wire.

### Does Huawei Technologies Co Ltd: SUN2000-38KTL-USL0 {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 20 A at 240 V means PASS (120% Rule).

### How does Huawei Technologies Co Ltd: SUN2000-38KTL-USL0 {240V} compare to ABB: PVI-38-OUTD-S-US-A {240V}?

Huawei Technologies Co Ltd: SUN2000-38KTL-USL0 {240V} delivers 3,800 W AC at 99.03% CEC efficiency with a 420 V DC ceiling, while ABB: PVI-38-OUTD-S-US-A {240V} outputs 3,800 W at 240 V.

## Related Pages

Explore Huawei Technologies Co Ltd hardware, ABB: PVI-38-OUTD-S-US-A {240V}, utility rates, and NEC 705.12 sizing calculators alongside Huawei Technologies Co Ltd: SUN2000-38KTL-USL0 {240V}.

[All Huawei Technologies Co Ltd Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/huawei-technologies-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Huawei Technologies Co Ltd

- [All Huawei Technologies Co Ltd Specs](https://epri-peac.com/solar-equipment/brands/huawei-technologies-co-ltd/)
- [Huawei Technologies Co Ltd: SUN2000-100KTL-USH0 {800V}](https://epri-peac.com/solar-equipment/inverters/huawei-technologies-co-ltd/huawei-technologies-co-ltd-sun2000-100ktl-ush0-800v/)
- [Huawei Technologies Co Ltd: SUN2000-40KTL-US {480V}](https://epri-peac.com/solar-equipment/inverters/huawei-technologies-co-ltd/huawei-technologies-co-ltd-sun2000-40ktl-us-480v/)
- [Huawei Technologies Co Ltd: SUN2000-36KTL-US {480V}](https://epri-peac.com/solar-equipment/inverters/huawei-technologies-co-ltd/huawei-technologies-co-ltd-sun2000-36ktl-us-480v/)
- [Huawei Technologies Co Ltd: SUN2000-33KTL-US {480V}](https://epri-peac.com/solar-equipment/inverters/huawei-technologies-co-ltd/huawei-technologies-co-ltd-sun2000-33ktl-us-480v/)
- [Huawei Technologies Co Ltd: SUN2000-30KTL-US {480V}](https://epri-peac.com/solar-equipment/inverters/huawei-technologies-co-ltd/huawei-technologies-co-ltd-sun2000-30ktl-us-480v/)