title: "HiQ Solar: TSXL480-10k {480V} Inverter (9,975W)"
url: https://epri-peac.com/solar-equipment/inverters/hiq-solar/hiq-solar-tsxl480-10k-480v/
description: "CEC specs for HiQ Solar: TSXL480-10k {480V}: 9,975W AC, 480V, 15A OCPD, and NEC 705.12 checks. Verified US government and CEC engineering data."
---

CEC Grid-Support Inverter

# HiQ Solar: TSXL480-10k {480V} — CEC Inverter Specifications

Manufacturer: [**HiQ Solar**](https://epri-peac.com/solar-equipment/brands/hiq-solar/) Registry: **CEC Verified Engineering Specification**

HiQ Solar: TSXL480-10k {480V} outputs 9,975 W AC at 480 V, 3-phase (12.0 A continuous, 15 A OCPD), ranking #314 of 2,343 CEC inverters at 98.06% efficiency with a 450-850 V MPPT window and 850 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 9,975 W

- **AC Voltage** : 480 V, 3-phase

- **Min PV Breaker** : 15 A (14 AWG Cu)

- **CEC Efficiency** : 98.06%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does HiQ Solar: TSXL480-10k {480V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 480 V, 3-phase grid-support overview for HiQ Solar: TSXL480-10k {480V}. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Rated at 9,975 W AC (12.0 A continuous), HiQ Solar: TSXL480-10k {480V} ranks #314 of 2,343 CEC units at 98.06% efficiency (+0.04 pts vs the 98.02% 480 V median). Minimum 75 C copper conductor sizing for its 15 A circuit is 14 AWG Cu per NEC Table 310.16. Cold-weather string Voc must remain under 850 V DC at record local winter lows.

## Where Does HiQ Solar: TSXL480-10k {480V} Fall Across Listed CEC Models?

Marks HiQ Solar: TSXL480-10k {480V} (9,975 W AC) across the California Energy Commission inverter AC capacity distribution. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

## What Dataset Percentiles Define HiQ Solar: TSXL480-10k {480V}?

Benchmarks HiQ Solar: TSXL480-10k {480V} continuous AC output, 98.06% CEC weighted efficiency, and 15 A OCPD breaker demand.

## What Do the Dataset Ranks Show for HiQ Solar: TSXL480-10k {480V}?

Four key NEC 705.12 and California Energy Commission metrics defining HiQ Solar: TSXL480-10k {480V} by HiQ Solar. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Eff #314 / 2,343

### 98.06% CEC Weighted Efficiency

+0.04 pts vs the 98.02% 480 V median; overall power rank #923 (9,975 W, top 39.5%; higher than 60.5% of peers).

NEC 705.12 Check

### 15 A Required Backfeed OCPD

125% x 12.0 A = 15.0 A -> 15 A standard OCPD using 14 AWG Cu (75 C).

MPPT Window

### 450 V - 850 V (Max 850 V DC)

Tracking span of 400.0 V; listed since 2019-02-15 (grid-tied PV inverter).

Commercial / 3-Phase Fit

### PASS (120% Commercial Busbar)

Evaluated for 480 V, 3-phase switchgear (200A Bus / 200A Main (480V) to 1,200A Bus / 1,200A Main (480V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 9975.0W / 480 V 3-phase -> 12.0 A | Breaker >= 1.25 * 12.0 = 15.0 A -> 15 A

CEC Inverters.csv for HiQ Solar: TSXL480-10k {480V}: Paco=9975.0 W, Vac=480 V, Vdcmax=850.0 V, Eff=98.06%.

**Result:** Min 15 A breaker & 14 AWG Cu (75 C); 1,200A Bus / 1,200A Main (480V): PASS (120% Commercial Busbar).

## What Are the Published CEC Specifications for HiQ Solar: TSXL480-10k {480V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for HiQ Solar: TSXL480-10k {480V}. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Official California Energy Commission (NREL SAM) test parameters for HiQ Solar: TSXL480-10k {480V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 9,975 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 480 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 850 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 450 V - 850 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 13.5625 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 98.06% | Calculated AC/DC conversion ratio from CEC test protocol |
| **CEC Listing Date & Hybrid** | 2019-02-15 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |

## What Switchgear Limits Apply to HiQ Solar: TSXL480-10k {480V} (480 V, 3-phase)?

Evaluates HiQ Solar: TSXL480-10k {480V} (15 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates HiQ Solar: TSXL480-10k {480V} (15 A required OCPD at 480 V, 3-phase) across standard distribution busbars.

| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **200A Bus / 200A Main (480V)** | 40 A | 15 A | PASS (120% Commercial Busbar) |
| **400A Bus / 400A Main (480V)** | 80 A | 15 A | PASS (120% Commercial Busbar) |
| **600A Bus / 600A Main (480V)** | 120 A | 15 A | PASS (120% Commercial Busbar) |
| **800A Bus / 800A Main (480V)** | 160 A | 15 A | PASS (120% Commercial Busbar) |
| **1,200A Bus / 1,200A Main (480V)** | 240 A | 15 A | PASS (120% Commercial Busbar) |

## Which CEC PV Module Strings Pair With HiQ Solar: TSXL480-10k {480V}?

Sample PV string lengths aligned within 450-850 V MPPT and 850 V DC max at -10 C. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sampled CEC PV modules aligned within 450.0-850.0 V MPPT and 850.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 11 to 15 panels | 8.85 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 14 to 20 panels | 8.8 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 14 to 18 panels | 7.65 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 16 to 20 panels | 4.0 kW |

## Which Competing Grid-Support Inverters Compare to HiQ Solar: TSXL480-10k {480V}?

Competing CEC grid-support inverters near 9,975 W AC and 480 V, 3-phase, led by Fronius International GmbH: Fronius Symo 100-3 480 {480V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Fronius International GmbH: Fronius Symo 100-3 480 {480V}**](https://epri-peac.com/solar-equipment/inverters/fronius-international-gmbh/fronius-international-gmbh-fronius-symo-100-3-480-480v/) Fronius International GmbH | 9,995 W | +20 W | 480.0 V | 800.0 V | 97.42% |
| [**Fronius International GmbH: Fronius Symo 125-3 480 {480V}**](https://epri-peac.com/solar-equipment/inverters/fronius-international-gmbh/fronius-international-gmbh-fronius-symo-125-3-480-480v/) Fronius International GmbH | 12,500 W | +2525 W | 480.0 V | 800.0 V | 97.57% |
| [**Fronius International GmbH: Fronius Symo 150-3 480 {480V}**](https://epri-peac.com/solar-equipment/inverters/fronius-international-gmbh/fronius-international-gmbh-fronius-symo-150-3-480-480v/) Fronius International GmbH | 15,000 W | +5025 W | 480.0 V | 800.0 V | 97.47% |
| [**Fronius International GmbH: Fronius Symo Advanced 150-3 480 {480V}**](https://epri-peac.com/solar-equipment/inverters/fronius-international-gmbh/fronius-international-gmbh-fronius-symo-advanced-150-3-480-480v/) Fronius International GmbH | 15,197 W | +5222 W | 480.0 V | 800.0 V | 97.48% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for HiQ Solar: TSXL480-10k {480V}?

Check HiQ Solar: TSXL480-10k {480V} (9,975 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 850 V DC on HiQ Solar: TSXL480-10k {480V}.

### HiQ Solar: TSXL480-10k {480V} Panel & Wire Spec

Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (12.0 A continuous).

### Alternative Inverter Comparison

Compare efficiency (98.06%) and MPPT window (450-850 V) directly against Fronius International GmbH: Fronius Symo 100-3 480 {480V} (9,995 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for HiQ Solar: TSXL480-10k {480V} by HiQ Solar covering breaker sizing, MPPT limits, and 480 V, 3-phase interconnection.

### What breaker and wire size does HiQ Solar: TSXL480-10k {480V} require?

At 9,975 W continuous AC (480 V, 3-phase), continuous current is 12.0 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.

### What commercial switchgear or feeder sizing does HiQ Solar: TSXL480-10k {480V} require?

At 9,975 W AC and 480 V, 3-phase, continuous line current is 12.0 A, requiring a 15 A OCPD and 1,200A Bus / 1,200A Main (480V) or NEC 705.11 interconnection.

### How does HiQ Solar: TSXL480-10k {480V} compare to Fronius International GmbH: Fronius Symo 100-3 480 {480V}?

HiQ Solar: TSXL480-10k {480V} delivers 9,975 W AC at 98.06% CEC efficiency with a 850 V DC ceiling, while Fronius International GmbH: Fronius Symo 100-3 480 {480V} outputs 9,995 W at 480 V, 3-phase.

## Related Pages

Explore HiQ Solar hardware, Fronius International GmbH: Fronius Symo 100-3 480 {480V}, utility rates, and NEC 705.12 sizing calculators alongside HiQ Solar: TSXL480-10k {480V}.

[All HiQ Solar Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/hiq-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From HiQ Solar

- [All HiQ Solar Specs](https://epri-peac.com/solar-equipment/brands/hiq-solar/)