Ginlong Technologies Co Ltd: Solis-1P9K-4G-US {240V} outputs 9,000 W AC at 240 V (37.5 A continuous, 50 A OCPD), ranking #684 of 2,343 CEC inverters at 97.3% efficiency with a 250-500 V MPPT window and 500 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 9,000 W

- **AC Voltage** : 240 V

- **Min PV Breaker** : 50 A (8 AWG Cu)

- **CEC Efficiency** : 97.3%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Ginlong Technologies Co Ltd: Solis-1P9K-4G-US {240V} Compare Against Peer CEC Listings?

Breaker sizing (50 A), 8 AWG Cu wire rules, and DC input limits for Ginlong Technologies Co Ltd: Solis-1P9K-4G-US {240V}.

Classified as a grid-tied PV inverter (listed since 2024-03-11), Ginlong Technologies Co Ltd: Solis-1P9K-4G-US {240V} requires 46.9 A design capacity -> 50 A breaker using 8 AWG Cu copper at 75 C terminals. Weighted efficiency sits at 97.3% (+0.48 pts vs overall CEC median) across 2,343 CEC models, while its 50 a backfeed breaker exceeds a 200a/200a panel's 40 a ceiling, requiring a 175 a main derate, 225 a busbar, or nec 705.11 tap.

## Where Does Ginlong Technologies Co Ltd: Solis-1P9K-4G-US {240V} Fall Across Listed CEC Models?

Output power comparison showing where Ginlong Technologies Co Ltd: Solis-1P9K-4G-US {240V} sits among all 2,343 CEC-listed grid-support inverters.

## What Dataset Percentiles Define Ginlong Technologies Co Ltd: Solis-1P9K-4G-US {240V}?

Relative ranking of Ginlong Technologies Co Ltd: Solis-1P9K-4G-US {240V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

## What Do the Dataset Ranks Show for Ginlong Technologies Co Ltd: Solis-1P9K-4G-US {240V}?

Snapshot of Ginlong Technologies Co Ltd: Solis-1P9K-4G-US {240V} efficiency rank (#684), OCPD breaker size, MPPT span, and busbar verdict.

Eff #684 / 2,343

### 97.3% CEC Weighted Efficiency

+0.62 pts vs the 96.68% 240 V median; overall power rank #1,024 (9,000 W, top 43.7%; higher than 56.3% of peers).

NEC 705.12 Check

### 50 A Required Backfeed OCPD

125% x 37.5 A = 46.9 A -> 50 A standard OCPD using 8 AWG Cu (75 C).

MPPT Window

### 250 V - 500 V (Max 500 V DC)

Tracking span of 250.0 V; listed since 2024-03-11 (grid-tied PV inverter).

Panel Fit (240V)

### Needs Derate / Tap 705.11

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 9000.0W / 240 V -> 37.5 A | Breaker >= 1.25 * 37.5 = 46.9 A -> 50 A

CEC Inverters.csv for Ginlong Technologies Co Ltd: Solis-1P9K-4G-US {240V}: Paco=9000.0 W, Vac=240 V, Vdcmax=500.0 V, Eff=97.3%.

**Result:** Min 50 A breaker & 8 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.

## What Are the Published CEC Specifications for Ginlong Technologies Co Ltd: Solis-1P9K-4G-US {240V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Ginlong Technologies Co Ltd: Solis-1P9K-4G-US {240V}.

Official California Energy Commission (NREL SAM) test parameters for Ginlong Technologies Co Ltd: Solis-1P9K-4G-US {240V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 9,000 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 500 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 250 V - 500 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 24.3404 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 97.3% | Calculated AC/DC conversion ratio from CEC test protocol |
| **CEC Listing Date & Hybrid** | 2024-03-11 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |

## Can a Residential Panel Meet 120% Busbar Limits for Ginlong Technologies Co Ltd: Solis-1P9K-4G-US {240V}?

NEC 705.12(B)(3)(2) backfeed compliance table for Ginlong Technologies Co Ltd: Solis-1P9K-4G-US {240V} at 240 V.

Evaluates Ginlong Technologies Co Ltd: Solis-1P9K-4G-US {240V} (50 A required OCPD at 240 V) across standard distribution busbars.

| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **100A Bus / 100A Main** | 20 A | 50 A | Needs Derate / Tap 705.11 |
| **150A Bus / 150A Main** | 30 A | 50 A | Needs Derate / Tap 705.11 |
| **200A Bus / 200A Main** | 40 A | 50 A | Needs Derate / Tap 705.11 |
| **200A Bus / 175A Main** | 65 A | 50 A | PASS (120% Rule) |
| **225A Bus / 200A Main** | 70 A | 50 A | PASS (120% Rule) |

## Which CEC PV Module Strings Pair With Ginlong Technologies Co Ltd: Solis-1P9K-4G-US {240V}?

Minimum and maximum series solar module strings fitting Ginlong Technologies Co Ltd: Solis-1P9K-4G-US {240V} MPPT and 500 V limits.

Sampled CEC PV modules aligned within 250.0-500.0 V MPPT and 500.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 6 to 8 panels | 4.72 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 8 to 11 panels | 4.84 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 8 to 11 panels | 4.67 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 9 to 12 panels | 2.4 kW |

## Which Competing Grid-Support Inverters Compare to Ginlong Technologies Co Ltd: Solis-1P9K-4G-US {240V}?

Peer 240 V CEC inverters near 9,000 W AC output such as Base Power Inc: MIN 9000TL-XH-US {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Base Power Inc: MIN 9000TL-XH-US {240V}**](https://epri-peac.com/solar-equipment/inverters/base-power-inc/base-power-inc-min-9000tl-xh-us-240v/) Base Power Inc | 9,063 W | +63 W | 240.0 V | 480.0 V | 97.69% |
| [**ABB: UNO-86-TL-OUTD-S-US-A {240V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-uno-86-tl-outd-s-us-a-240v/) ABB | 8,600 W | -400 W | 240.0 V | 480.0 V | 97.03% |
| [**ABB: UNO-86-TL-OUTD-S-US-Z-A {240V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-uno-86-tl-outd-s-us-z-a-240v/) ABB | 8,600 W | -400 W | 240.0 V | 480.0 V | 97.03% |
| [**ABB: UNO-86-TL-OUTD-S-US-Z-M-A {240V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-uno-86-tl-outd-s-us-z-m-a-240v/) ABB | 8,600 W | -400 W | 240.0 V | 480.0 V | 97.03% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Ginlong Technologies Co Ltd: Solis-1P9K-4G-US {240V}?

Check Ginlong Technologies Co Ltd: Solis-1P9K-4G-US {240V} (9,000 W AC, 50 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Its 50 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 500 V DC on Ginlong Technologies Co Ltd: Solis-1P9K-4G-US {240V}.

### Ginlong Technologies Co Ltd: Solis-1P9K-4G-US {240V} Panel & Wire Spec

Size 75 C copper conductors at 8 AWG Cu on a 50 A OCPD breaker (37.5 A continuous).

### Alternative Inverter Comparison

Compare efficiency (97.3%) and MPPT window (250-500 V) directly against Base Power Inc: MIN 9000TL-XH-US {240V} (9,063 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Ginlong Technologies Co Ltd: Solis-1P9K-4G-US {240V} by Ginlong Technologies Co Ltd covering breaker sizing, MPPT limits, and 240 V interconnection.

### What breaker and wire size does Ginlong Technologies Co Ltd: Solis-1P9K-4G-US {240V} require?

At 9,000 W continuous AC (240 V), continuous current is 37.5 A; 125% NEC 690.8/705.12 sizing requires a 50 A breaker and 8 AWG Cu (75 C) wire.

### Does Ginlong Technologies Co Ltd: Solis-1P9K-4G-US {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 50 A at 240 V means Needs Derate / Tap 705.11.

### How does Ginlong Technologies Co Ltd: Solis-1P9K-4G-US {240V} compare to Base Power Inc: MIN 9000TL-XH-US {240V}?

Ginlong Technologies Co Ltd: Solis-1P9K-4G-US {240V} delivers 9,000 W AC at 97.3% CEC efficiency with a 500 V DC ceiling, while Base Power Inc: MIN 9000TL-XH-US {240V} outputs 9,063 W at 240 V.

## Related Pages

Explore Ginlong Technologies Co Ltd hardware, Base Power Inc: MIN 9000TL-XH-US {240V}, utility rates, and NEC 705.12 sizing calculators alongside Ginlong Technologies Co Ltd: Solis-1P9K-4G-US {240V}.

[All Ginlong Technologies Co Ltd Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/ginlong-technologies-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Ginlong Technologies Co Ltd

- [All Ginlong Technologies Co Ltd Specs](https://epri-peac.com/solar-equipment/brands/ginlong-technologies-co-ltd/)
- [Ginlong Technologies Co Ltd: S6-GU350K-EHV-US-M16 {800V}](https://epri-peac.com/solar-equipment/inverters/ginlong-technologies-co-ltd/ginlong-technologies-co-ltd-s6-gu350k-ehv-us-m16-800v/)
- [Ginlong Technologies Co Ltd: S6-GU350K-EHV-US-M12 {800V}](https://epri-peac.com/solar-equipment/inverters/ginlong-technologies-co-ltd/ginlong-technologies-co-ltd-s6-gu350k-ehv-us-m12-800v/)
- [Ginlong Technologies Co Ltd: Solis-255K-EHV-5G-US {800V}](https://epri-peac.com/solar-equipment/inverters/ginlong-technologies-co-ltd/ginlong-technologies-co-ltd-solis-255k-ehv-5g-us-800v/)
- [Ginlong Technologies Co Ltd: S6-GU250K-EHV-US-M12 {600V}](https://epri-peac.com/solar-equipment/inverters/ginlong-technologies-co-ltd/ginlong-technologies-co-ltd-s6-gu250k-ehv-us-m12-600v/)
- [Ginlong Technologies Co Ltd: Solis-255K-EHV-5G-US-PLUS {800V}](https://epri-peac.com/solar-equipment/inverters/ginlong-technologies-co-ltd/ginlong-technologies-co-ltd-solis-255k-ehv-5g-us-plus-800v/)