title: "Ginlong Technologies Co Ltd Inverter (4,600W)"
url: https://epri-peac.com/solar-equipment/inverters/ginlong-technologies-co-ltd/ginlong-technologies-co-ltd-solis-1p46k-4g-us-240v/
description: "CEC specs for Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V}: 4,600W AC, 240V, 25A OCPD, and NEC 705.12 checks. Source-verified US engineering data."
---

CEC Grid-Support Inverter

# Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V} — CEC Inverter Specifications

Manufacturer: [**Ginlong Technologies Co Ltd**](https://epri-peac.com/solar-equipment/brands/ginlong-technologies-co-ltd/) Registry: **CEC Verified Engineering Specification**

Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V} outputs 4,600 W AC at 240 V (19.2 A continuous, 25 A OCPD), ranking #1,075 of 2,343 CEC inverters at 96.96% efficiency with a 200-500 V MPPT window and 500 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 4,600 W

- **AC Voltage** : 240 V

- **Min PV Breaker** : 25 A (10 AWG Cu)

- **CEC Efficiency** : 96.96%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V} Compare Against Peer CEC Listings?

CEC efficiency rank (#1,075), 200-500 V MPPT tracking, and panel fit for Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V}.

Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V} from Ginlong Technologies Co Ltd outputs 19.2 A continuous AC at 240 V (4,600 W AC, rank #1,582). Paired with 10 AWG Cu conductors and a 25 A OCPD, its 96.96% CEC efficiency compares closely with ABB: UNO-DM-46-TL-PLUS-US-SB-RA {240V} (4,600 W). Keep NEC 690.7 winter string Voc below 500 V DC.

## Where Does Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V} at 4,600 W continuous AC output. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

## What Dataset Percentiles Define Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V}?

Dataset percentiles comparing Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V} against 2,343 certified grid-support inverters nationwide. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

## What Do the Dataset Ranks Show for Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V}?

Engineering highlights for Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V} covering efficiency, 10 AWG Cu feeder, and panel compatibility.

Eff #1,075 / 2,343

### 96.96% CEC Weighted Efficiency

+0.28 pts vs the 96.68% 240 V median; overall power rank #1,582 (4,600 W, below CEC median; higher than 32.0% of peers).

NEC 705.12 Check

### 25 A Required Backfeed OCPD

125% x 19.2 A = 24.0 A -> 25 A standard OCPD using 10 AWG Cu (75 C).

MPPT Window

### 200 V - 500 V (Max 500 V DC)

Tracking span of 300.0 V; listed since 2020-09-11 (grid-tied PV inverter).

Panel Fit (240V)

### PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 4600.0W / 240 V -> 19.2 A | Breaker >= 1.25 * 19.2 = 24.0 A -> 25 A

CEC Inverters.csv for Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V}: Paco=4600.0 W, Vac=240 V, Vdcmax=500.0 V, Eff=96.96%.

**Result:** Min 25 A breaker & 10 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

## What Are the Published CEC Specifications for Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V}?

California Energy Commission Solar Equipment List parameters for Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V} (grid-tied PV inverter) interconnection.

Official California Energy Commission (NREL SAM) test parameters for Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 4,600 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 500 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 200 V - 500 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 13.1783 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 96.96% | Calculated AC/DC conversion ratio from CEC test protocol |
| **CEC Listing Date & Hybrid** | 2020-09-11 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |

## Can a Residential Panel Meet 120% Busbar Limits for Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V}?

Panelboard and switchgear backfeed allowances for Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V} (25 A OCPD). Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Evaluates Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V} (25 A required OCPD at 240 V) across standard distribution busbars.

| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **100A Bus / 100A Main** | 20 A | 25 A | Needs Derate / Tap 705.11 |
| **150A Bus / 150A Main** | 30 A | 25 A | PASS (120% Rule) |
| **200A Bus / 200A Main** | 40 A | 25 A | PASS (120% Rule) |
| **200A Bus / 175A Main** | 65 A | 25 A | PASS (120% Rule) |
| **225A Bus / 200A Main** | 70 A | 25 A | PASS (120% Rule) |

## Which CEC PV Module Strings Pair With Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V}. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Sampled CEC PV modules aligned within 200.0-500.0 V MPPT and 500.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 5 to 8 panels | 4.72 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 6 to 11 panels | 4.84 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 6 to 11 panels | 4.67 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 7 to 12 panels | 2.4 kW |

## Which Competing Grid-Support Inverters Compare to Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V}?

Four alternative CEC inverters matched to Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V} (4,600 W AC), led by ABB: UNO-DM-46-TL-PLUS-US-SB-RA {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**ABB: UNO-DM-46-TL-PLUS-US-SB-RA {240V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-uno-dm-46-tl-plus-us-sb-ra-240v/) ABB | 4,600 W | Tie (0 W) | 240.0 V | 480.0 V | 96.17% |
| [**ABB: UNO-DM-46-TL-PLUS-US-SB-RA-Q {240V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-uno-dm-46-tl-plus-us-sb-ra-q-240v/) ABB | 4,600 W | Tie (0 W) | 240.0 V | 480.0 V | 96.17% |
| [**ABB: UNO-DM-46-TL-PLUS-US-SE-RA {240V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-uno-dm-46-tl-plus-us-se-ra-240v/) ABB | 4,600 W | Tie (0 W) | 240.0 V | 480.0 V | 96.17% |
| [**ABB: UNO-DM-46-TL-PLUS-US-SZ-RA {240V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-uno-dm-46-tl-plus-us-sz-ra-240v/) ABB | 4,600 W | Tie (0 W) | 240.0 V | 480.0 V | 96.17% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V}?

Check Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V} (4,600 W AC, 25 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Requires a 25 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 500 V DC on Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V}.

### Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V} Panel & Wire Spec

Size 75 C copper conductors at 10 AWG Cu on a 25 A OCPD breaker (19.2 A continuous).

### Alternative Inverter Comparison

Compare efficiency (96.96%) and MPPT window (200-500 V) directly against ABB: UNO-DM-46-TL-PLUS-US-SB-RA {240V} (4,600 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V} by Ginlong Technologies Co Ltd covering breaker sizing, MPPT limits, and 240 V interconnection.

### What breaker and wire size does Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V} require?

At 4,600 W continuous AC (240 V), continuous current is 19.2 A; 125% NEC 690.8/705.12 sizing requires a 25 A breaker and 10 AWG Cu (75 C) wire.

### Does Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 25 A at 240 V means PASS (120% Rule).

### How does Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V} compare to ABB: UNO-DM-46-TL-PLUS-US-SB-RA {240V}?

Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V} delivers 4,600 W AC at 96.96% CEC efficiency with a 500 V DC ceiling, while ABB: UNO-DM-46-TL-PLUS-US-SB-RA {240V} outputs 4,600 W at 240 V.

## Related Pages

Explore Ginlong Technologies Co Ltd hardware, ABB: UNO-DM-46-TL-PLUS-US-SB-RA {240V}, utility rates, and NEC 705.12 sizing calculators alongside Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V}.

[All Ginlong Technologies Co Ltd Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/ginlong-technologies-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Ginlong Technologies Co Ltd

- [All Ginlong Technologies Co Ltd Specs](https://epri-peac.com/solar-equipment/brands/ginlong-technologies-co-ltd/)
- [Ginlong Technologies Co Ltd: S6-GU350K-EHV-US-M16 {800V}](https://epri-peac.com/solar-equipment/inverters/ginlong-technologies-co-ltd/ginlong-technologies-co-ltd-s6-gu350k-ehv-us-m16-800v/)
- [Ginlong Technologies Co Ltd: S6-GU350K-EHV-US-M12 {800V}](https://epri-peac.com/solar-equipment/inverters/ginlong-technologies-co-ltd/ginlong-technologies-co-ltd-s6-gu350k-ehv-us-m12-800v/)
- [Ginlong Technologies Co Ltd: Solis-255K-EHV-5G-US {800V}](https://epri-peac.com/solar-equipment/inverters/ginlong-technologies-co-ltd/ginlong-technologies-co-ltd-solis-255k-ehv-5g-us-800v/)
- [Ginlong Technologies Co Ltd: S6-GU250K-EHV-US-M12 {600V}](https://epri-peac.com/solar-equipment/inverters/ginlong-technologies-co-ltd/ginlong-technologies-co-ltd-s6-gu250k-ehv-us-m12-600v/)
- [Ginlong Technologies Co Ltd: Solis-255K-EHV-5G-US-PLUS {800V}](https://epri-peac.com/solar-equipment/inverters/ginlong-technologies-co-ltd/ginlong-technologies-co-ltd-solis-255k-ehv-5g-us-plus-800v/)