CEC Grid-Support Inverter

# Ginlong Technologies Co Ltd: S6-GC30K-LV-US {240V} — CEC Inverter Specifications

Manufacturer: [**Ginlong Technologies Co Ltd**](https://epri-peac.com/solar-equipment/brands/ginlong-technologies-co-ltd/) Registry: **CEC Verified Engineering Specification**

Ginlong Technologies Co Ltd: S6-GC30K-LV-US {240V} outputs 29,878 W AC at 240 V, 3-phase (71.9 A continuous, 90 A OCPD), ranking #1,683 of 2,343 CEC inverters at 96.38% efficiency with a 340-680 V MPPT window and 680 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 29,878 W

- **AC Voltage** : 240 V, 3-phase

- **Min PV Breaker** : 90 A (3 AWG Cu)

- **CEC Efficiency** : 96.38%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Ginlong Technologies Co Ltd: S6-GC30K-LV-US {240V} Compare Against Peer CEC Listings?

CEC efficiency rank (#1,683), 340-680 V MPPT tracking, and panel fit for Ginlong Technologies Co Ltd: S6-GC30K-LV-US {240V}.

Ginlong Technologies Co Ltd: S6-GC30K-LV-US {240V} from Ginlong Technologies Co Ltd outputs 71.9 A continuous AC at 240 V, 3-phase (29,878 W AC, rank #575). Paired with 3 AWG Cu conductors and a 90 A OCPD, its 96.38% CEC efficiency compares closely with Amensolar Ess Co Ltd: N3H-X16US {240V} (16,199 W). Keep NEC 690.7 winter string Voc below 680 V DC.

## Where Does Ginlong Technologies Co Ltd: S6-GC30K-LV-US {240V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting Ginlong Technologies Co Ltd: S6-GC30K-LV-US {240V} at 29,878 W continuous AC output. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

## What Dataset Percentiles Define Ginlong Technologies Co Ltd: S6-GC30K-LV-US {240V}?

Dataset percentiles comparing Ginlong Technologies Co Ltd: S6-GC30K-LV-US {240V} against 2,343 certified grid-support inverters nationwide. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

## What Do the Dataset Ranks Show for Ginlong Technologies Co Ltd: S6-GC30K-LV-US {240V}?

Engineering highlights for Ginlong Technologies Co Ltd: S6-GC30K-LV-US {240V} covering efficiency, 3 AWG Cu feeder, and panel compatibility.

Eff #1,683 / 2,343

### 96.38% CEC Weighted Efficiency

-0.30 pts vs the 96.68% 240 V median; overall power rank #575 (29,878 W, top 24.5%; higher than 75.5% of peers).

NEC 705.12 Check

### 90 A Required Backfeed OCPD

125% x 71.9 A = 89.9 A -> 90 A standard OCPD using 3 AWG Cu (75 C).

MPPT Window

### 340 V - 680 V (Max 680 V DC)

Tracking span of 340.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

### Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 240 V, 3-phase switchgear (200A Bus / 200A Main (240V) to 1,200A Bus / 1,200A Main (240V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 29877.6W / 240 V 3-phase -> 71.9 A | Breaker >= 1.25 * 71.9 = 89.9 A -> 90 A

CEC Inverters.csv for Ginlong Technologies Co Ltd: S6-GC30K-LV-US {240V}: Paco=29877.6 W, Vac=240 V, Vdcmax=680.0 V, Eff=96.38%.

**Result:** Min 90 A breaker & 3 AWG Cu (75 C); 1,200A Bus / 1,200A Main (240V): PASS (120% Commercial Busbar).

## What Are the Published CEC Specifications for Ginlong Technologies Co Ltd: S6-GC30K-LV-US {240V}?

California Energy Commission Solar Equipment List parameters for Ginlong Technologies Co Ltd: S6-GC30K-LV-US {240V} (grid-tied PV inverter) interconnection.

Official California Energy Commission (NREL SAM) test parameters for Ginlong Technologies Co Ltd: S6-GC30K-LV-US {240V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 29,878 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 240 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 680 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 340 V - 680 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 53.4457 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 96.38% | Calculated AC/DC conversion ratio from CEC test protocol |
| **Inverter Topology** | Hybrid: No (Grid-Tied PV) | CEC Solar Equipment List grid-support certification |

## What Switchgear Limits Apply to Ginlong Technologies Co Ltd: S6-GC30K-LV-US {240V} (240 V, 3-phase)?

Panelboard and switchgear backfeed allowances for Ginlong Technologies Co Ltd: S6-GC30K-LV-US {240V} (90 A OCPD). Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Evaluates Ginlong Technologies Co Ltd: S6-GC30K-LV-US {240V} (90 A required OCPD at 240 V, 3-phase) across standard distribution busbars.

| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **200A Bus / 200A Main (240V)** | 40 A | 90 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **400A Bus / 400A Main (240V)** | 80 A | 90 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **600A Bus / 600A Main (240V)** | 120 A | 90 A | PASS (120% Commercial Busbar) |
| **800A Bus / 800A Main (240V)** | 160 A | 90 A | PASS (120% Commercial Busbar) |
| **1,200A Bus / 1,200A Main (240V)** | 240 A | 90 A | PASS (120% Commercial Busbar) |

## Which CEC PV Module Strings Pair With Ginlong Technologies Co Ltd: S6-GC30K-LV-US {240V}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for Ginlong Technologies Co Ltd: S6-GC30K-LV-US {240V}. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Sampled CEC PV modules aligned within 340.0-680.0 V MPPT and 680.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 8 to 12 panels | 7.08 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 11 to 16 panels | 7.04 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 10 to 15 panels | 6.38 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 12 to 16 panels | 3.2 kW |

## Which Competing Grid-Support Inverters Compare to Ginlong Technologies Co Ltd: S6-GC30K-LV-US {240V}?

Four alternative CEC inverters matched to Ginlong Technologies Co Ltd: S6-GC30K-LV-US {240V} (29,878 W AC), led by Amensolar Ess Co Ltd: N3H-X16US {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Amensolar Ess Co Ltd: N3H-X16US {240V}**](https://epri-peac.com/solar-equipment/inverters/amensolar-ess-co-ltd/amensolar-ess-co-ltd-n3h-x16us-240v/) Amensolar Ess Co Ltd | 16,199 W | -13679 W | 240.0 V | 430.0 V | 96.25% |
| [**Amensolar Ess Co Ltd: N3H-X12US {240V}**](https://epri-peac.com/solar-equipment/inverters/amensolar-ess-co-ltd/amensolar-ess-co-ltd-n3h-x12us-240v/) Amensolar Ess Co Ltd | 12,214 W | -17664 W | 240.0 V | 430.0 V | 96.17% |
| [**Chint Power Systems America: CPS ECH12KTL/US {240V}**](https://epri-peac.com/solar-equipment/inverters/chint-power-systems-america/chint-power-systems-america-cps-ech12ktl-us-240v/) Chint Power Systems America | 11,990 W | -17888 W | 240.0 V | 480.0 V | 96.59% |
| [**Delta Electronics: S12_BDI {240V}**](https://epri-peac.com/solar-equipment/inverters/delta-electronics/delta-electronics-s12-bdi-240v/) Delta Electronics | 11,589 W | -18289 W | 240.0 V | 480.0 V | 96.99% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Ginlong Technologies Co Ltd: S6-GC30K-LV-US {240V}?

Check Ginlong Technologies Co Ltd: S6-GC30K-LV-US {240V} (29,878 W AC, 90 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 240 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (240V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 680 V DC on Ginlong Technologies Co Ltd: S6-GC30K-LV-US {240V}.

### Ginlong Technologies Co Ltd: S6-GC30K-LV-US {240V} Panel & Wire Spec

Size 75 C copper conductors at 3 AWG Cu on a 90 A OCPD breaker (71.9 A continuous).

### Alternative Inverter Comparison

Compare efficiency (96.38%) and MPPT window (340-680 V) directly against Amensolar Ess Co Ltd: N3H-X16US {240V} (16,199 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Ginlong Technologies Co Ltd: S6-GC30K-LV-US {240V} by Ginlong Technologies Co Ltd covering breaker sizing, MPPT limits, and 240 V, 3-phase interconnection.

### What breaker and wire size does Ginlong Technologies Co Ltd: S6-GC30K-LV-US {240V} require?

At 29,878 W continuous AC (240 V, 3-phase), continuous current is 71.9 A; 125% NEC 690.8/705.12 sizing requires a 90 A breaker and 3 AWG Cu (75 C) wire.

### What commercial switchgear or feeder sizing does Ginlong Technologies Co Ltd: S6-GC30K-LV-US {240V} require?

At 29,878 W AC and 240 V, 3-phase, continuous line current is 71.9 A, requiring a 90 A OCPD and 1,200A Bus / 1,200A Main (240V) or NEC 705.11 interconnection.

### How does Ginlong Technologies Co Ltd: S6-GC30K-LV-US {240V} compare to Amensolar Ess Co Ltd: N3H-X16US {240V}?

Ginlong Technologies Co Ltd: S6-GC30K-LV-US {240V} delivers 29,878 W AC at 96.38% CEC efficiency with a 680 V DC ceiling, while Amensolar Ess Co Ltd: N3H-X16US {240V} outputs 16,199 W at 240 V, 3-phase.

## Related Pages

Explore Ginlong Technologies Co Ltd hardware, Amensolar Ess Co Ltd: N3H-X16US {240V}, utility rates, and NEC 705.12 sizing calculators alongside Ginlong Technologies Co Ltd: S6-GC30K-LV-US {240V}.

[All Ginlong Technologies Co Ltd Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/ginlong-technologies-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Ginlong Technologies Co Ltd

- [All Ginlong Technologies Co Ltd Specs](https://epri-peac.com/solar-equipment/brands/ginlong-technologies-co-ltd/)
- [Ginlong Technologies Co Ltd: S6-GU350K-EHV-US-M16 {800V}](https://epri-peac.com/solar-equipment/inverters/ginlong-technologies-co-ltd/ginlong-technologies-co-ltd-s6-gu350k-ehv-us-m16-800v/)
- [Ginlong Technologies Co Ltd: S6-GU350K-EHV-US-M12 {800V}](https://epri-peac.com/solar-equipment/inverters/ginlong-technologies-co-ltd/ginlong-technologies-co-ltd-s6-gu350k-ehv-us-m12-800v/)
- [Ginlong Technologies Co Ltd: Solis-255K-EHV-5G-US {800V}](https://epri-peac.com/solar-equipment/inverters/ginlong-technologies-co-ltd/ginlong-technologies-co-ltd-solis-255k-ehv-5g-us-800v/)
- [Ginlong Technologies Co Ltd: S6-GU250K-EHV-US-M12 {600V}](https://epri-peac.com/solar-equipment/inverters/ginlong-technologies-co-ltd/ginlong-technologies-co-ltd-s6-gu250k-ehv-us-m12-600v/)
- [Ginlong Technologies Co Ltd: Solis-255K-EHV-5G-US-PLUS {800V}](https://epri-peac.com/solar-equipment/inverters/ginlong-technologies-co-ltd/ginlong-technologies-co-ltd-solis-255k-ehv-5g-us-plus-800v/)