CEC Grid-Support Inverter

# Ginlong Technologies Co Ltd: S6-EH3P50K04-NV-YD-H-US {480V} — CEC Inverter Specifications

Manufacturer: [**Ginlong Technologies Co Ltd**](https://epri-peac.com/solar-equipment/brands/ginlong-technologies-co-ltd/) Registry: **CEC Verified Engineering Specification**

Ginlong Technologies Co Ltd: S6-EH3P50K04-NV-YD-H-US {480V} outputs 49,800 W AC at 480 V, 3-phase (59.9 A continuous, 80 A OCPD), ranking #841 of 2,343 CEC inverters at 97.14% efficiency with a 450-850 V MPPT window and 850 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 49,800 W

- **AC Voltage** : 480 V, 3-phase

- **Min PV Breaker** : 80 A (4 AWG Cu)

- **CEC Efficiency** : 97.14%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Ginlong Technologies Co Ltd: S6-EH3P50K04-NV-YD-H-US {480V} Compare Against Peer CEC Listings?

Breaker sizing (80 A), 4 AWG Cu wire rules, and DC input limits for Ginlong Technologies Co Ltd: S6-EH3P50K04-NV-YD-H-US {480V}.

For NEC 705.12 solar interconnection, Ginlong Technologies Co Ltd: S6-EH3P50K04-NV-YD-H-US {480V} outputs 59.9 A continuous AC at 480 V, 3-phase and needs an 80 A backfeed breaker on 4 AWG Cu (75 C). Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap. Conversion efficiency scores 97.14% (#841 of 2,343, +0.32 pts vs overall CEC median).

## Where Does Ginlong Technologies Co Ltd: S6-EH3P50K04-NV-YD-H-US {480V} Fall Across Listed CEC Models?

Output power comparison showing where Ginlong Technologies Co Ltd: S6-EH3P50K04-NV-YD-H-US {480V} sits among all 2,343 CEC-listed grid-support inverters.

## What Dataset Percentiles Define Ginlong Technologies Co Ltd: S6-EH3P50K04-NV-YD-H-US {480V}?

Relative ranking of Ginlong Technologies Co Ltd: S6-EH3P50K04-NV-YD-H-US {480V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

## What Do the Dataset Ranks Show for Ginlong Technologies Co Ltd: S6-EH3P50K04-NV-YD-H-US {480V}?

Snapshot of Ginlong Technologies Co Ltd: S6-EH3P50K04-NV-YD-H-US {480V} efficiency rank (#841), OCPD breaker size, MPPT span, and busbar verdict.

Eff #841 / 2,343

### 97.14% CEC Weighted Efficiency

-0.88 pts vs the 98.02% 480 V median; overall power rank #463 (49,800 W, top 19.8%; higher than 80.2% of peers).

NEC 705.12 Check

### 80 A Required Backfeed OCPD

125% x 59.9 A = 74.9 A -> 80 A standard OCPD using 4 AWG Cu (75 C).

MPPT Window

### 450 V - 850 V (Max 850 V DC)

Tracking span of 400.0 V; listed since 2025-11-12 (hybrid battery-capable inverter).

Commercial / 3-Phase Fit

### PASS (120% Commercial Busbar)

Evaluated for 480 V, 3-phase switchgear (200A Bus / 200A Main (480V) to 1,200A Bus / 1,200A Main (480V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 49800.3W / 480 V 3-phase -> 59.9 A | Breaker >= 1.25 * 59.9 = 74.9 A -> 80 A

CEC Inverters.csv for Ginlong Technologies Co Ltd: S6-EH3P50K04-NV-YD-H-US {480V}: Paco=49800.3 W, Vac=480 V, Vdcmax=850.0 V, Eff=97.14%.

**Result:** Min 80 A breaker & 4 AWG Cu (75 C); 1,200A Bus / 1,200A Main (480V): PASS (120% Commercial Busbar).

## What Are the Published CEC Specifications for Ginlong Technologies Co Ltd: S6-EH3P50K04-NV-YD-H-US {480V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Ginlong Technologies Co Ltd: S6-EH3P50K04-NV-YD-H-US {480V}.

Official California Energy Commission (NREL SAM) test parameters for Ginlong Technologies Co Ltd: S6-EH3P50K04-NV-YD-H-US {480V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 49,800 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 480 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 850 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 450 V - 850 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 78.8707 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 97.14% | Calculated AC/DC conversion ratio from CEC test protocol |
| **CEC Listing Date & Hybrid** | 2025-11-12 / Hybrid: Yes (Battery Capable) | Utility interconnection approval metadata |

## What Switchgear Limits Apply to Ginlong Technologies Co Ltd: S6-EH3P50K04-NV-YD-H-US {480V} (480 V, 3-phase)?

NEC 705.12(B)(3)(2) backfeed compliance table for Ginlong Technologies Co Ltd: S6-EH3P50K04-NV-YD-H-US {480V} at 480 V, 3-phase.

Evaluates Ginlong Technologies Co Ltd: S6-EH3P50K04-NV-YD-H-US {480V} (80 A required OCPD at 480 V, 3-phase) across standard distribution busbars.

| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **200A Bus / 200A Main (480V)** | 40 A | 80 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **400A Bus / 400A Main (480V)** | 80 A | 80 A | PASS (120% Commercial Busbar) |
| **600A Bus / 600A Main (480V)** | 120 A | 80 A | PASS (120% Commercial Busbar) |
| **800A Bus / 800A Main (480V)** | 160 A | 80 A | PASS (120% Commercial Busbar) |
| **1,200A Bus / 1,200A Main (480V)** | 240 A | 80 A | PASS (120% Commercial Busbar) |

## Which CEC PV Module Strings Pair With Ginlong Technologies Co Ltd: S6-EH3P50K04-NV-YD-H-US {480V}?

Minimum and maximum series solar module strings fitting Ginlong Technologies Co Ltd: S6-EH3P50K04-NV-YD-H-US {480V} MPPT and 850 V limits.

Sampled CEC PV modules aligned within 450.0-850.0 V MPPT and 850.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 11 to 15 panels | 8.85 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 14 to 20 panels | 8.8 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 14 to 18 panels | 7.65 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 16 to 20 panels | 4.0 kW |

## Which Competing Grid-Support Inverters Compare to Ginlong Technologies Co Ltd: S6-EH3P50K04-NV-YD-H-US {480V}?

Peer 480 V, 3-phase CEC inverters near 49,800 W AC output such as Fortress Power LLC: FP-Nano-50k-N {480V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Fortress Power LLC: FP-Nano-50k-N {480V}**](https://epri-peac.com/solar-equipment/inverters/fortress-power-llc/fortress-power-llc-fp-nano-50k-n-480v/) Fortress Power LLC | 49,803 W | +3 W | 480.0 V | 850.0 V | 97.41% |
| [**CSI Solar Co Ltd: CSI-50K-T480GL03-U {480V}**](https://epri-peac.com/solar-equipment/inverters/csi-solar-co-ltd/csi-solar-co-ltd-csi-50k-t480gl03-u-480v/) CSI Solar Co Ltd | 49,848 W | +48 W | 480.0 V | 850.0 V | 98.29% |
| [**CSI Solar Co Ltd: CSI-50K-T480GL01-UB {480V}**](https://epri-peac.com/solar-equipment/inverters/csi-solar-co-ltd/csi-solar-co-ltd-csi-50k-t480gl01-ub-480v/) CSI Solar Co Ltd | 49,916 W | +116 W | 480.0 V | 850.0 V | 98.32% |
| [**ABB: TRIO-500-TL-OUTD-US-480 {480V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-trio-500-tl-outd-us-480-480v/) ABB | 50,000 W | +200 W | 480.0 V | 800.0 V | 98.27% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Ginlong Technologies Co Ltd: S6-EH3P50K04-NV-YD-H-US {480V}?

Check Ginlong Technologies Co Ltd: S6-EH3P50K04-NV-YD-H-US {480V} (49,800 W AC, 80 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 850 V DC on Ginlong Technologies Co Ltd: S6-EH3P50K04-NV-YD-H-US {480V}.

### Ginlong Technologies Co Ltd: S6-EH3P50K04-NV-YD-H-US {480V} Panel & Wire Spec

Size 75 C copper conductors at 4 AWG Cu on an 80 A OCPD breaker (59.9 A continuous).

### Alternative Inverter Comparison

Compare efficiency (97.14%) and MPPT window (450-850 V) directly against Fortress Power LLC: FP-Nano-50k-N {480V} (49,803 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Ginlong Technologies Co Ltd: S6-EH3P50K04-NV-YD-H-US {480V} by Ginlong Technologies Co Ltd covering breaker sizing, MPPT limits, and 480 V, 3-phase interconnection.

### What breaker and wire size does Ginlong Technologies Co Ltd: S6-EH3P50K04-NV-YD-H-US {480V} require?

At 49,800 W continuous AC (480 V, 3-phase), continuous current is 59.9 A; 125% NEC 690.8/705.12 sizing requires an 80 A breaker and 4 AWG Cu (75 C) wire.

### What commercial switchgear or feeder sizing does Ginlong Technologies Co Ltd: S6-EH3P50K04-NV-YD-H-US {480V} require?

At 49,800 W AC and 480 V, 3-phase, continuous line current is 59.9 A, requiring an 80 A OCPD and 1,200A Bus / 1,200A Main (480V) or NEC 705.11 interconnection.

### How does Ginlong Technologies Co Ltd: S6-EH3P50K04-NV-YD-H-US {480V} compare to Fortress Power LLC: FP-Nano-50k-N {480V}?

Ginlong Technologies Co Ltd: S6-EH3P50K04-NV-YD-H-US {480V} delivers 49,800 W AC at 97.14% CEC efficiency with a 850 V DC ceiling, while Fortress Power LLC: FP-Nano-50k-N {480V} outputs 49,803 W at 480 V, 3-phase.

## Related Pages

Explore Ginlong Technologies Co Ltd hardware, Fortress Power LLC: FP-Nano-50k-N {480V}, utility rates, and NEC 705.12 sizing calculators alongside Ginlong Technologies Co Ltd: S6-EH3P50K04-NV-YD-H-US {480V}.

[All Ginlong Technologies Co Ltd Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/ginlong-technologies-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Ginlong Technologies Co Ltd

- [All Ginlong Technologies Co Ltd Specs](https://epri-peac.com/solar-equipment/brands/ginlong-technologies-co-ltd/)
- [Ginlong Technologies Co Ltd: S6-GU350K-EHV-US-M16 {800V}](https://epri-peac.com/solar-equipment/inverters/ginlong-technologies-co-ltd/ginlong-technologies-co-ltd-s6-gu350k-ehv-us-m16-800v/)
- [Ginlong Technologies Co Ltd: S6-GU350K-EHV-US-M12 {800V}](https://epri-peac.com/solar-equipment/inverters/ginlong-technologies-co-ltd/ginlong-technologies-co-ltd-s6-gu350k-ehv-us-m12-800v/)
- [Ginlong Technologies Co Ltd: Solis-255K-EHV-5G-US {800V}](https://epri-peac.com/solar-equipment/inverters/ginlong-technologies-co-ltd/ginlong-technologies-co-ltd-solis-255k-ehv-5g-us-800v/)
- [Ginlong Technologies Co Ltd: S6-GU250K-EHV-US-M12 {600V}](https://epri-peac.com/solar-equipment/inverters/ginlong-technologies-co-ltd/ginlong-technologies-co-ltd-s6-gu250k-ehv-us-m12-600v/)
- [Ginlong Technologies Co Ltd: Solis-255K-EHV-5G-US-PLUS {800V}](https://epri-peac.com/solar-equipment/inverters/ginlong-technologies-co-ltd/ginlong-technologies-co-ltd-solis-255k-ehv-5g-us-plus-800v/)