title: "Ginlong Technologies Co Ltd Inverter (25,884W)"
url: https://epri-peac.com/solar-equipment/inverters/ginlong-technologies-co-ltd/ginlong-technologies-co-ltd-s6-eh3p30k03-lv-yd-h-us-21a-208v/
description: "CEC specs for Ginlong Technologies Co Ltd: S6-EH3P30K03-LV-YD-H-US(21A) {208V}: 25,884W AC, 208V, 90A OCPD, and NEC 705.12 checks."
---

CEC Grid-Support Inverter

# Ginlong Technologies Co Ltd: S6-EH3P30K03-LV-YD-H-US(21A) {208V} — CEC Inverter Specifications

Manufacturer: [**Ginlong Technologies Co Ltd**](https://epri-peac.com/solar-equipment/brands/ginlong-technologies-co-ltd/) Registry: **CEC Verified Engineering Specification**

Ginlong Technologies Co Ltd: S6-EH3P30K03-LV-YD-H-US(21A) {208V} outputs 25,884 W AC at 208 V, 3-phase (71.8 A continuous, 90 A OCPD), ranking #689 of 2,343 CEC inverters at 97.29% efficiency with a 500-850 V MPPT window and 850 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 25,884 W

- **AC Voltage** : 208 V, 3-phase

- **Min PV Breaker** : 90 A (3 AWG Cu)

- **CEC Efficiency** : 97.29%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Ginlong Technologies Co Ltd: S6-EH3P30K03-LV-YD-H-US(21A) {208V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 208 V, 3-phase grid-support overview for Ginlong Technologies Co Ltd: S6-EH3P30K03-LV-YD-H-US(21A) {208V}.

Rated at 25,884 W AC (71.8 A continuous), Ginlong Technologies Co Ltd: S6-EH3P30K03-LV-YD-H-US(21A) {208V} ranks #689 of 2,343 CEC units at 97.29% efficiency (+0.88 pts vs the 96.41% 208 V median). Minimum 75 C copper conductor sizing for its 90 A circuit is 3 AWG Cu per NEC Table 310.16. Cold-weather string Voc must remain under 850 V DC at record local winter lows.

## Where Does Ginlong Technologies Co Ltd: S6-EH3P30K03-LV-YD-H-US(21A) {208V} Fall Across Listed CEC Models?

Marks Ginlong Technologies Co Ltd: S6-EH3P30K03-LV-YD-H-US(21A) {208V} (25,884 W AC) across the California Energy Commission inverter AC capacity distribution.

## What Dataset Percentiles Define Ginlong Technologies Co Ltd: S6-EH3P30K03-LV-YD-H-US(21A) {208V}?

Benchmarks Ginlong Technologies Co Ltd: S6-EH3P30K03-LV-YD-H-US(21A) {208V} continuous AC output, 97.29% CEC weighted efficiency, and 90 A OCPD breaker demand.

## What Do the Dataset Ranks Show for Ginlong Technologies Co Ltd: S6-EH3P30K03-LV-YD-H-US(21A) {208V}?

Four key NEC 705.12 and California Energy Commission metrics defining Ginlong Technologies Co Ltd: S6-EH3P30K03-LV-YD-H-US(21A) {208V} by Ginlong Technologies Co Ltd.

Eff #689 / 2,343

### 97.29% CEC Weighted Efficiency

+0.88 pts vs the 96.41% 208 V median; overall power rank #592 (25,884 W, top 25.3%; higher than 74.7% of peers).

NEC 705.12 Check

### 90 A Required Backfeed OCPD

125% x 71.8 A = 89.8 A -> 90 A standard OCPD using 3 AWG Cu (75 C).

MPPT Window

### 500 V - 850 V (Max 850 V DC)

Tracking span of 350.0 V; active in CEC directory (hybrid battery-capable inverter).

Commercial / 3-Phase Fit

### Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 208 V, 3-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 25883.5W / 208 V 3-phase -> 71.8 A | Breaker >= 1.25 * 71.8 = 89.8 A -> 90 A

CEC Inverters.csv for Ginlong Technologies Co Ltd: S6-EH3P30K03-LV-YD-H-US(21A) {208V}: Paco=25883.5 W, Vac=208 V, Vdcmax=850.0 V, Eff=97.29%.

**Result:** Min 90 A breaker & 3 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).

## What Are the Published CEC Specifications for Ginlong Technologies Co Ltd: S6-EH3P30K03-LV-YD-H-US(21A) {208V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for Ginlong Technologies Co Ltd: S6-EH3P30K03-LV-YD-H-US(21A) {208V}.

Official California Energy Commission (NREL SAM) test parameters for Ginlong Technologies Co Ltd: S6-EH3P30K03-LV-YD-H-US(21A) {208V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 25,884 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 208 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 850 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 500 V - 850 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 39.4131 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 97.29% | Calculated AC/DC conversion ratio from CEC test protocol |
| **Inverter Topology** | Hybrid: Yes (Battery Capable) | CEC Solar Equipment List grid-support certification |

## What Switchgear Limits Apply to Ginlong Technologies Co Ltd: S6-EH3P30K03-LV-YD-H-US(21A) {208V} (208 V, 3-phase)?

Evaluates Ginlong Technologies Co Ltd: S6-EH3P30K03-LV-YD-H-US(21A) {208V} (90 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates Ginlong Technologies Co Ltd: S6-EH3P30K03-LV-YD-H-US(21A) {208V} (90 A required OCPD at 208 V, 3-phase) across standard distribution busbars.

| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **200A Bus / 200A Main (208V)** | 40 A | 90 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **400A Bus / 400A Main (208V)** | 80 A | 90 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **600A Bus / 600A Main (208V)** | 120 A | 90 A | PASS (120% Commercial Busbar) |
| **800A Bus / 800A Main (208V)** | 160 A | 90 A | PASS (120% Commercial Busbar) |
| **1,200A Bus / 1,200A Main (208V)** | 240 A | 90 A | PASS (120% Commercial Busbar) |

## Which CEC PV Module Strings Pair With Ginlong Technologies Co Ltd: S6-EH3P30K03-LV-YD-H-US(21A) {208V}?

Sample PV string lengths aligned within 500-850 V MPPT and 850 V DC max at -10 C. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sampled CEC PV modules aligned within 500.0-850.0 V MPPT and 850.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 12 to 15 panels | 8.85 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 15 to 20 panels | 8.8 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 15 to 18 panels | 7.65 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 18 to 20 panels | 4.0 kW |

## Which Competing Grid-Support Inverters Compare to Ginlong Technologies Co Ltd: S6-EH3P30K03-LV-YD-H-US(21A) {208V}?

Competing CEC grid-support inverters near 25,884 W AC and 208 V, 3-phase, led by Chint Power Systems America: CPS SCA25KTL-DO/US-208 {208V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Chint Power Systems America: CPS SCA25KTL-DO/US-208 {208V}**](https://epri-peac.com/solar-equipment/inverters/chint-power-systems-america/chint-power-systems-america-cps-sca25ktl-do-us-208-208v/) Chint Power Systems America | 25,000 W | -884 W | 208.0 V | 850.0 V | 96.26% |
| [**EcoFlow Inc: EF-PCS-24 {208V 24kW}**](https://epri-peac.com/solar-equipment/inverters/ecoflow-inc/ecoflow-inc-ef-pcs-24-208v-24kw/) EcoFlow Inc | 24,291 W | -1592 W | 208.0 V | 480.0 V | 96.01% |
| [**CSI Solar Co Ltd: CSI-30K-T208GL03-U {208V}**](https://epri-peac.com/solar-equipment/inverters/csi-solar-co-ltd/csi-solar-co-ltd-csi-30k-t208gl03-u-208v/) CSI Solar Co Ltd | 29,878 W | +3994 W | 208.0 V | 680.0 V | 96.38% |
| [**EG4 Electronics LLC: IV-16000-HYB-AW-FX-xx {208V}**](https://epri-peac.com/solar-equipment/inverters/eg4-electronics-llc/eg4-electronics-llc-iv-16000-hyb-aw-fx-xx-208v/) EG4 Electronics LLC | 13,899 W | -11985 W | 208.0 V | 440.0 V | 96.46% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Ginlong Technologies Co Ltd: S6-EH3P30K03-LV-YD-H-US(21A) {208V}?

Check Ginlong Technologies Co Ltd: S6-EH3P30K03-LV-YD-H-US(21A) {208V} (25,884 W AC, 90 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 208 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 850 V DC on Ginlong Technologies Co Ltd: S6-EH3P30K03-LV-YD-H-US(21A) {208V}.

### Ginlong Technologies Co Ltd: S6-EH3P30K03-LV-YD-H-US(21A) {208V} Panel & Wire Spec

Size 75 C copper conductors at 3 AWG Cu on a 90 A OCPD breaker (71.8 A continuous).

### Alternative Inverter Comparison

Compare efficiency (97.29%) and MPPT window (500-850 V) directly against Chint Power Systems America: CPS SCA25KTL-DO/US-208 {208V} (25,000 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Ginlong Technologies Co Ltd: S6-EH3P30K03-LV-YD-H-US(21A) {208V} by Ginlong Technologies Co Ltd covering breaker sizing, MPPT limits, and 208 V, 3-phase interconnection.

### What breaker and wire size does Ginlong Technologies Co Ltd: S6-EH3P30K03-LV-YD-H-US(21A) {208V} require?

At 25,884 W continuous AC (208 V, 3-phase), continuous current is 71.8 A; 125% NEC 690.8/705.12 sizing requires a 90 A breaker and 3 AWG Cu (75 C) wire.

### What commercial switchgear or feeder sizing does Ginlong Technologies Co Ltd: S6-EH3P30K03-LV-YD-H-US(21A) {208V} require?

At 25,884 W AC and 208 V, 3-phase, continuous line current is 71.8 A, requiring a 90 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.

### How does Ginlong Technologies Co Ltd: S6-EH3P30K03-LV-YD-H-US(21A) {208V} compare to Chint Power Systems America: CPS SCA25KTL-DO/US-208 {208V}?

Ginlong Technologies Co Ltd: S6-EH3P30K03-LV-YD-H-US(21A) {208V} delivers 25,884 W AC at 97.29% CEC efficiency with a 850 V DC ceiling, while Chint Power Systems America: CPS SCA25KTL-DO/US-208 {208V} outputs 25,000 W at 208 V, 3-phase.

## Related Pages

Explore Ginlong Technologies Co Ltd hardware, Chint Power Systems America: CPS SCA25KTL-DO/US-208 {208V}, utility rates, and NEC 705.12 sizing calculators alongside Ginlong Technologies Co Ltd: S6-EH3P30K03-LV-YD-H-US(21A) {208V}.

[All Ginlong Technologies Co Ltd Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/ginlong-technologies-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Ginlong Technologies Co Ltd

- [All Ginlong Technologies Co Ltd Specs](https://epri-peac.com/solar-equipment/brands/ginlong-technologies-co-ltd/)
- [Ginlong Technologies Co Ltd: S6-GU350K-EHV-US-M16 {800V}](https://epri-peac.com/solar-equipment/inverters/ginlong-technologies-co-ltd/ginlong-technologies-co-ltd-s6-gu350k-ehv-us-m16-800v/)
- [Ginlong Technologies Co Ltd: S6-GU350K-EHV-US-M12 {800V}](https://epri-peac.com/solar-equipment/inverters/ginlong-technologies-co-ltd/ginlong-technologies-co-ltd-s6-gu350k-ehv-us-m12-800v/)
- [Ginlong Technologies Co Ltd: Solis-255K-EHV-5G-US {800V}](https://epri-peac.com/solar-equipment/inverters/ginlong-technologies-co-ltd/ginlong-technologies-co-ltd-solis-255k-ehv-5g-us-800v/)
- [Ginlong Technologies Co Ltd: S6-GU250K-EHV-US-M12 {600V}](https://epri-peac.com/solar-equipment/inverters/ginlong-technologies-co-ltd/ginlong-technologies-co-ltd-s6-gu250k-ehv-us-m12-600v/)
- [Ginlong Technologies Co Ltd: Solis-255K-EHV-5G-US-PLUS {800V}](https://epri-peac.com/solar-equipment/inverters/ginlong-technologies-co-ltd/ginlong-technologies-co-ltd-solis-255k-ehv-5g-us-plus-800v/)