title: "Generac Power Systems Inc: PM-820 Inverter (820W)"
url: https://epri-peac.com/solar-equipment/inverters/generac-power-systems-inc/generac-power-systems-inc-pm-820-208v/
description: "CEC specs for Generac Power Systems Inc: PM-820 {208V}: 820W AC, 208V, 15A OCPD, and NEC 705.12 checks. Verified US government and CEC engineering data."
---

CEC Grid-Support Inverter

# Generac Power Systems Inc: PM-820 {208V} — CEC Inverter Specifications

Manufacturer: [**Generac Power Systems Inc**](https://epri-peac.com/solar-equipment/brands/generac-power-systems-inc/) Registry: **CEC Verified Engineering Specification**

Generac Power Systems Inc: PM-820 {208V} outputs 820 W AC at 208 V, commercial single-phase (3.9 A continuous, 15 A OCPD), ranking #1,348 of 2,343 CEC inverters at 96.61% efficiency with a 31.5-40 V MPPT window and 40 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 820 W

- **AC Voltage** : 208 V, commercial single-phase

- **Min PV Breaker** : 15 A (14 AWG Cu)

- **CEC Efficiency** : 96.61%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Generac Power Systems Inc: PM-820 {208V} Compare Against Peer CEC Listings?

How Generac Power Systems Inc Generac Power Systems Inc: PM-820 {208V} compares on 96.61% efficiency, MPPT span, and 120% busbar interconnection.

Generac Power Systems Inc certifies Generac Power Systems Inc: PM-820 {208V} (grid-tied PV inverter, active in CEC directory) at 820 W AC (4,180 W below the 5,000 W 208 V median). Its 40 V DC ceiling pairs with an MPPT window of 31.5-40 V (span 8.5 V). Under NEC 690.8/705.12, 125% sizing demands 14 AWG Cu conductors on a 15 A OCPD.

## Where Does Generac Power Systems Inc: PM-820 {208V} Fall Across Listed CEC Models?

Position of Generac Power Systems Inc: PM-820 {208V} (820 W AC) relative to the 7,680 W CEC median inverter.

## What Dataset Percentiles Define Generac Power Systems Inc: PM-820 {208V}?

Percentile placement of Generac Power Systems Inc: PM-820 {208V} across AC power class, conversion efficiency, and backfeed breaker size.

## What Do the Dataset Ranks Show for Generac Power Systems Inc: PM-820 {208V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for Generac Power Systems Inc: PM-820 {208V}.

Eff #1,348 / 2,343

### 96.61% CEC Weighted Efficiency

+0.20 pts vs the 96.41% 208 V median; overall power rank #1,860 (820 W, below CEC median; higher than 20.6% of peers).

NEC 705.12 Check

### 15 A Required Backfeed OCPD

125% x 3.9 A = 4.9 A -> 15 A standard OCPD using 14 AWG Cu (75 C).

MPPT Window

### 31.5 V - 40 V (Max 40 V DC)

Tracking span of 8.5 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

### PASS (120% Commercial Busbar)

Evaluated for 208 V, commercial single-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 820.0W / 208 V -> 3.9 A | Breaker >= 1.25 * 3.9 = 4.9 A -> 15 A

CEC Inverters.csv for Generac Power Systems Inc: PM-820 {208V}: Paco=820.0 W, Vac=208 V, Vdcmax=40.0 V, Eff=96.61%.

**Result:** Min 15 A breaker & 14 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).

## What Are the Published CEC Specifications for Generac Power Systems Inc: PM-820 {208V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for Generac Power Systems Inc: PM-820 {208V}.

Official California Energy Commission (NREL SAM) test parameters for Generac Power Systems Inc: PM-820 {208V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 820 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 208 V, commercial single-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 40 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 31.5 V - 40 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 22.635 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 96.61% | Calculated AC/DC conversion ratio from CEC test protocol |
| **Inverter Topology** | Hybrid: No (Grid-Tied PV) | CEC Solar Equipment List grid-support certification |

## What Switchgear Limits Apply to Generac Power Systems Inc: PM-820 {208V} (208 V, commercial single-phase)?

Check whether Generac Power Systems Inc: PM-820 {208V} (15 A breaker) fits without main breaker derate or supply-side taps.

Evaluates Generac Power Systems Inc: PM-820 {208V} (15 A required OCPD at 208 V, commercial single-phase) across standard distribution busbars.

| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **200A Bus / 200A Main (208V)** | 40 A | 15 A | PASS (120% Commercial Busbar) |
| **400A Bus / 400A Main (208V)** | 80 A | 15 A | PASS (120% Commercial Busbar) |
| **600A Bus / 600A Main (208V)** | 120 A | 15 A | PASS (120% Commercial Busbar) |
| **800A Bus / 800A Main (208V)** | 160 A | 15 A | PASS (120% Commercial Busbar) |
| **1,200A Bus / 1,200A Main (208V)** | 240 A | 15 A | PASS (120% Commercial Busbar) |

## Which Competing Grid-Support Inverters Compare to Generac Power Systems Inc: PM-820 {208V}?

Alternative CEC inverters comparable to Generac Power Systems Inc: PM-820 {208V}, including Cherry Solution Co Ltd: CMI-800S-SA {208V} (800 W) at 208 V, commercial single-phase.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Cherry Solution Co Ltd: CMI-800S-SA {208V}**](https://epri-peac.com/solar-equipment/inverters/cherry-solution-co-ltd/cherry-solution-co-ltd-cmi-800s-sa-208v/) Cherry Solution Co Ltd | 800 W | -20 W | 208.0 V | 50.0 V | 95.84% |
| [**Cherry Solution Co Ltd: CMI-800S-WA {208V}**](https://epri-peac.com/solar-equipment/inverters/cherry-solution-co-ltd/cherry-solution-co-ltd-cmi-800s-wa-208v/) Cherry Solution Co Ltd | 800 W | -20 W | 208.0 V | 50.0 V | 95.84% |
| [**Aptos Solar Technology LLC: MAC-800 {208V}**](https://epri-peac.com/solar-equipment/inverters/aptos-solar-technology-llc/aptos-solar-technology-llc-mac-800-208v/) Aptos Solar Technology LLC | 767 W | -53 W | 208.0 V | 48.0 V | 96.12% |
| [**Aptos Solar Technology LLC: MAC-800R {208V}**](https://epri-peac.com/solar-equipment/inverters/aptos-solar-technology-llc/aptos-solar-technology-llc-mac-800r-208v/) Aptos Solar Technology LLC | 767 W | -53 W | 208.0 V | 48.0 V | 96.12% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Generac Power Systems Inc: PM-820 {208V}?

Check Generac Power Systems Inc: PM-820 {208V} (820 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 40 V DC on Generac Power Systems Inc: PM-820 {208V}.

### Generac Power Systems Inc: PM-820 {208V} Panel & Wire Spec

Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (3.9 A continuous).

### Alternative Inverter Comparison

Compare efficiency (96.61%) and MPPT window (31.5-40 V) directly against Cherry Solution Co Ltd: CMI-800S-SA {208V} (800 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Generac Power Systems Inc: PM-820 {208V} by Generac Power Systems Inc covering breaker sizing, MPPT limits, and 208 V, commercial single-phase interconnection.

### What breaker and wire size does Generac Power Systems Inc: PM-820 {208V} require?

At 820 W continuous AC (208 V, commercial single-phase), continuous current is 3.9 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.

### What commercial switchgear or feeder sizing does Generac Power Systems Inc: PM-820 {208V} require?

At 820 W AC and 208 V, commercial single-phase, continuous line current is 3.9 A, requiring a 15 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.

### How does Generac Power Systems Inc: PM-820 {208V} compare to Cherry Solution Co Ltd: CMI-800S-SA {208V}?

Generac Power Systems Inc: PM-820 {208V} delivers 820 W AC at 96.61% CEC efficiency with a 40 V DC ceiling, while Cherry Solution Co Ltd: CMI-800S-SA {208V} outputs 800 W at 208 V, commercial single-phase.

## Related Pages

Explore Generac Power Systems Inc hardware, Cherry Solution Co Ltd: CMI-800S-SA {208V}, utility rates, and NEC 705.12 sizing calculators alongside Generac Power Systems Inc: PM-820 {208V}.

[All Generac Power Systems Inc Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/generac-power-systems-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Generac Power Systems Inc

- [All Generac Power Systems Inc Specs](https://epri-peac.com/solar-equipment/brands/generac-power-systems-inc/)
- [Generac Power Systems Inc: XVT114G03 {208V}](https://epri-peac.com/solar-equipment/inverters/generac-power-systems-inc/generac-power-systems-inc-xvt114g03-208v/)
- [Generac Power Systems Inc: APKE00075 {240V}](https://epri-peac.com/solar-equipment/inverters/generac-power-systems-inc/generac-power-systems-inc-apke00075-240v/)
- [Generac Power Systems Inc: X11402 {208V}](https://epri-peac.com/solar-equipment/inverters/generac-power-systems-inc/generac-power-systems-inc-x11402-208v/)
- [Generac Power Systems Inc: XVT076A03 {240V}](https://epri-peac.com/solar-equipment/inverters/generac-power-systems-inc/generac-power-systems-inc-xvt076a03-240v/)
- [Generac Power Systems Inc: X7602 {240V}](https://epri-peac.com/solar-equipment/inverters/generac-power-systems-inc/generac-power-systems-inc-x7602-240v/)