title: "Fronius International GmbH: Primo Inverter (3,802W)"
url: https://epri-peac.com/solar-equipment/inverters/fronius-international-gmbh/fronius-international-gmbh-primo-gen24-38-208-240-240v/
description: "CEC specs for Fronius International GmbH: Primo GEN24 38 208-240 {240V}: 3,802W AC, 240V, 20A OCPD, and NEC 705.12 checks. Source-verified US engineering data."
---

CEC Grid-Support Inverter

# Fronius International GmbH: Primo GEN24 38 208-240 {240V} — CEC Inverter Specifications

Manufacturer: [**Fronius International GmbH**](https://epri-peac.com/solar-equipment/brands/fronius-international-gmbh/) Registry: **CEC Verified Engineering Specification**

Fronius International GmbH: Primo GEN24 38 208-240 {240V} outputs 3,802 W AC at 240 V (15.8 A continuous, 20 A OCPD), ranking #630 of 2,343 CEC inverters at 97.38% efficiency with a 200-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 3,802 W

- **AC Voltage** : 240 V

- **Min PV Breaker** : 20 A (12 AWG Cu)

- **CEC Efficiency** : 97.38%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Fronius International GmbH: Primo GEN24 38 208-240 {240V} Compare Against Peer CEC Listings?

Breaker sizing (20 A), 12 AWG Cu wire rules, and DC input limits for Fronius International GmbH: Primo GEN24 38 208-240 {240V}.

For NEC 705.12 solar interconnection, Fronius International GmbH: Primo GEN24 38 208-240 {240V} outputs 15.8 A continuous AC at 240 V and needs a 20 A backfeed breaker on 12 AWG Cu (75 C). Requires a 20 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit). Conversion efficiency scores 97.38% (#630 of 2,343, +0.56 pts vs overall CEC median).

## Where Does Fronius International GmbH: Primo GEN24 38 208-240 {240V} Fall Across Listed CEC Models?

Output power comparison showing where Fronius International GmbH: Primo GEN24 38 208-240 {240V} sits among all 2,343 CEC-listed grid-support inverters.

## What Dataset Percentiles Define Fronius International GmbH: Primo GEN24 38 208-240 {240V}?

Relative ranking of Fronius International GmbH: Primo GEN24 38 208-240 {240V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

## What Do the Dataset Ranks Show for Fronius International GmbH: Primo GEN24 38 208-240 {240V}?

Snapshot of Fronius International GmbH: Primo GEN24 38 208-240 {240V} efficiency rank (#630), OCPD breaker size, MPPT span, and busbar verdict.

Eff #630 / 2,343

### 97.38% CEC Weighted Efficiency

+0.70 pts vs the 96.68% 240 V median; overall power rank #1,647 (3,802 W, below CEC median; higher than 29.7% of peers).

NEC 705.12 Check

### 20 A Required Backfeed OCPD

125% x 15.8 A = 19.8 A -> 20 A standard OCPD using 12 AWG Cu (75 C).

MPPT Window

### 200 V - 480 V (Max 480 V DC)

Tracking span of 280.0 V; listed since 2025-05-01 (hybrid battery-capable inverter).

Panel Fit (240V)

### PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 3802.0W / 240 V -> 15.8 A | Breaker >= 1.25 * 15.8 = 19.8 A -> 20 A

CEC Inverters.csv for Fronius International GmbH: Primo GEN24 38 208-240 {240V}: Paco=3802.0 W, Vac=240 V, Vdcmax=480.0 V, Eff=97.38%.

**Result:** Min 20 A breaker & 12 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

## What Are the Published CEC Specifications for Fronius International GmbH: Primo GEN24 38 208-240 {240V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Fronius International GmbH: Primo GEN24 38 208-240 {240V}.

Official California Energy Commission (NREL SAM) test parameters for Fronius International GmbH: Primo GEN24 38 208-240 {240V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 3,802 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 480 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 200 V - 480 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 9.76072 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 97.38% | Calculated AC/DC conversion ratio from CEC test protocol |
| **CEC Listing Date & Hybrid** | 2025-05-01 / Hybrid: Yes (Battery Capable) | Utility interconnection approval metadata |

## Can a Residential Panel Meet 120% Busbar Limits for Fronius International GmbH: Primo GEN24 38 208-240 {240V}?

NEC 705.12(B)(3)(2) backfeed compliance table for Fronius International GmbH: Primo GEN24 38 208-240 {240V} at 240 V.

Evaluates Fronius International GmbH: Primo GEN24 38 208-240 {240V} (20 A required OCPD at 240 V) across standard distribution busbars.

| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **100A Bus / 100A Main** | 20 A | 20 A | PASS (120% Rule) |
| **150A Bus / 150A Main** | 30 A | 20 A | PASS (120% Rule) |
| **200A Bus / 200A Main** | 40 A | 20 A | PASS (120% Rule) |
| **200A Bus / 175A Main** | 65 A | 20 A | PASS (120% Rule) |
| **225A Bus / 200A Main** | 70 A | 20 A | PASS (120% Rule) |

## Which CEC PV Module Strings Pair With Fronius International GmbH: Primo GEN24 38 208-240 {240V}?

Minimum and maximum series solar module strings fitting Fronius International GmbH: Primo GEN24 38 208-240 {240V} MPPT and 480 V limits.

Sampled CEC PV modules aligned within 200.0-480.0 V MPPT and 480.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 5 to 8 panels | 4.72 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 6 to 11 panels | 4.84 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 6 to 10 panels | 4.25 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 7 to 11 panels | 2.2 kW |

## Which Competing Grid-Support Inverters Compare to Fronius International GmbH: Primo GEN24 38 208-240 {240V}?

Peer 240 V CEC inverters near 3,802 W AC output such as ABB: PVI-38-OUTD-S-US-A {240V}. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**ABB: PVI-38-OUTD-S-US-A {240V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-pvi-38-outd-s-us-a-240v/) ABB | 3,800 W | -2 W | 240.0 V | 480.0 V | 96.2% |
| [**ABB: PVI-38-OUTD-S-US-Z-A {240V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-pvi-38-outd-s-us-z-a-240v/) ABB | 3,800 W | -2 W | 240.0 V | 480.0 V | 96.2% |
| [**ABB: PVI-38-OUTD-S-US-Z-M-A {240V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-pvi-38-outd-s-us-z-m-a-240v/) ABB | 3,800 W | -2 W | 240.0 V | 480.0 V | 96.2% |
| [**ABB: UNO-DM-38-TL-PLUS-US-SB-RA {240V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-uno-dm-38-tl-plus-us-sb-ra-240v/) ABB | 3,800 W | -2 W | 240.0 V | 480.0 V | 96.39% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Fronius International GmbH: Primo GEN24 38 208-240 {240V}?

Check Fronius International GmbH: Primo GEN24 38 208-240 {240V} (3,802 W AC, 20 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Requires a 20 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on Fronius International GmbH: Primo GEN24 38 208-240 {240V}.

### Fronius International GmbH: Primo GEN24 38 208-240 {240V} Panel & Wire Spec

Size 75 C copper conductors at 12 AWG Cu on a 20 A OCPD breaker (15.8 A continuous).

### Alternative Inverter Comparison

Compare efficiency (97.38%) and MPPT window (200-480 V) directly against ABB: PVI-38-OUTD-S-US-A {240V} (3,800 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Fronius International GmbH: Primo GEN24 38 208-240 {240V} by Fronius International GmbH covering breaker sizing, MPPT limits, and 240 V interconnection.

### What breaker and wire size does Fronius International GmbH: Primo GEN24 38 208-240 {240V} require?

At 3,802 W continuous AC (240 V), continuous current is 15.8 A; 125% NEC 690.8/705.12 sizing requires a 20 A breaker and 12 AWG Cu (75 C) wire.

### Does Fronius International GmbH: Primo GEN24 38 208-240 {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 20 A at 240 V means PASS (120% Rule).

### How does Fronius International GmbH: Primo GEN24 38 208-240 {240V} compare to ABB: PVI-38-OUTD-S-US-A {240V}?

Fronius International GmbH: Primo GEN24 38 208-240 {240V} delivers 3,802 W AC at 97.38% CEC efficiency with a 480 V DC ceiling, while ABB: PVI-38-OUTD-S-US-A {240V} outputs 3,800 W at 240 V.

## Related Pages

Explore Fronius International GmbH hardware, ABB: PVI-38-OUTD-S-US-A {240V}, utility rates, and NEC 705.12 sizing calculators alongside Fronius International GmbH: Primo GEN24 38 208-240 {240V}.

[All Fronius International GmbH Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/fronius-international-gmbh/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Fronius International GmbH

- [All Fronius International GmbH Specs](https://epri-peac.com/solar-equipment/brands/fronius-international-gmbh/)
- [Fronius International GmbH: Fronius Symo Advanced 240-3 480 {480V}](https://epri-peac.com/solar-equipment/inverters/fronius-international-gmbh/fronius-international-gmbh-fronius-symo-advanced-240-3-480-480v/)
- [Fronius International GmbH: Fronius Symo Advanced 240-3 480 Lite {480V}](https://epri-peac.com/solar-equipment/inverters/fronius-international-gmbh/fronius-international-gmbh-fronius-symo-advanced-240-3-480-lite-480v/)
- [Fronius International GmbH: Fronius Symo 240-3 480 {480V}](https://epri-peac.com/solar-equipment/inverters/fronius-international-gmbh/fronius-international-gmbh-fronius-symo-240-3-480-480v/)
- [Fronius International GmbH: Fronius Symo Advanced 227-3 480 {480V}](https://epri-peac.com/solar-equipment/inverters/fronius-international-gmbh/fronius-international-gmbh-fronius-symo-advanced-227-3-480-480v/)
- [Fronius International GmbH: Fronius Symo Advanced 227-3 480 Lite {480V}](https://epri-peac.com/solar-equipment/inverters/fronius-international-gmbh/fronius-international-gmbh-fronius-symo-advanced-227-3-480-lite-480v/)