title: "Fronius International GmbH Inverter (12,000W)"
url: https://epri-peac.com/solar-equipment/inverters/fronius-international-gmbh/fronius-international-gmbh-fronius-symo-120-3-208-240-208v/
description: "CEC specs for Fronius International GmbH: Fronius Symo 120-3 208-240 {208V}: 12,000W AC, 208V, 45A OCPD, and NEC 705.12 checks."
---

CEC Grid-Support Inverter

# Fronius International GmbH: Fronius Symo 120-3 208-240 {208V} — CEC Inverter Specifications

Manufacturer: [**Fronius International GmbH**](https://epri-peac.com/solar-equipment/brands/fronius-international-gmbh/) Registry: **CEC Verified Engineering Specification**

Fronius International GmbH: Fronius Symo 120-3 208-240 {208V} outputs 12,000 W AC at 208 V, 3-phase (33.3 A continuous, 45 A OCPD), ranking #2,071 of 2,343 CEC inverters at 95.81% efficiency with a 300-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 12,000 W

- **AC Voltage** : 208 V, 3-phase

- **Min PV Breaker** : 45 A (8 AWG Cu)

- **CEC Efficiency** : 95.81%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Fronius International GmbH: Fronius Symo 120-3 208-240 {208V} Compare Against Peer CEC Listings?

How Fronius International GmbH Fronius International GmbH: Fronius Symo 120-3 208-240 {208V} compares on 95.81% efficiency, MPPT span, and 120% busbar interconnection.

With a 300-480 V MPPT tracking band and 480 V DC ceiling, Fronius International GmbH: Fronius Symo 120-3 208-240 {208V} handles 12,000 W continuous AC (7,000 W above the 5,000 W 208 V median). Commercial 208 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap. Installers comparing Fronius International GmbH against Chint Power Systems America: CPS ECH12KTL/US {208V} (12,000 W) should verify whether listed since 2019-03-01 grid-support firmware meets local IEEE 1547 utility rules.

## Where Does Fronius International GmbH: Fronius Symo 120-3 208-240 {208V} Fall Across Listed CEC Models?

Position of Fronius International GmbH: Fronius Symo 120-3 208-240 {208V} (12,000 W AC) relative to the 7,680 W CEC median inverter.

## What Dataset Percentiles Define Fronius International GmbH: Fronius Symo 120-3 208-240 {208V}?

Percentile placement of Fronius International GmbH: Fronius Symo 120-3 208-240 {208V} across AC power class, conversion efficiency, and backfeed breaker size.

## What Do the Dataset Ranks Show for Fronius International GmbH: Fronius Symo 120-3 208-240 {208V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for Fronius International GmbH: Fronius Symo 120-3 208-240 {208V}.

Eff #2,071 / 2,343

### 95.81% CEC Weighted Efficiency

-0.60 pts vs the 96.41% 208 V median; overall power rank #723 (12,000 W, top 31.1%; higher than 68.9% of peers).

NEC 705.12 Check

### 45 A Required Backfeed OCPD

125% x 33.3 A = 41.6 A -> 45 A standard OCPD using 8 AWG Cu (75 C).

MPPT Window

### 300 V - 480 V (Max 480 V DC)

Tracking span of 180.0 V; listed since 2019-03-01 (grid-tied PV inverter).

Commercial / 3-Phase Fit

### PASS (120% Commercial Busbar)

Evaluated for 208 V, 3-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 12000.0W / 208 V 3-phase -> 33.3 A | Breaker >= 1.25 * 33.3 = 41.6 A -> 45 A

CEC Inverters.csv for Fronius International GmbH: Fronius Symo 120-3 208-240 {208V}: Paco=12000.0 W, Vac=208 V, Vdcmax=480.0 V, Eff=95.81%.

**Result:** Min 45 A breaker & 8 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).

## What Are the Published CEC Specifications for Fronius International GmbH: Fronius Symo 120-3 208-240 {208V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for Fronius International GmbH: Fronius Symo 120-3 208-240 {208V}.

Official California Energy Commission (NREL SAM) test parameters for Fronius International GmbH: Fronius Symo 120-3 208-240 {208V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 12,000 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 208 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 480 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 300 V - 480 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 35.7863 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 95.81% | Calculated AC/DC conversion ratio from CEC test protocol |
| **CEC Listing Date & Hybrid** | 2019-03-01 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |

## What Switchgear Limits Apply to Fronius International GmbH: Fronius Symo 120-3 208-240 {208V} (208 V, 3-phase)?

Check whether Fronius International GmbH: Fronius Symo 120-3 208-240 {208V} (45 A breaker) fits without main breaker derate or supply-side taps.

Evaluates Fronius International GmbH: Fronius Symo 120-3 208-240 {208V} (45 A required OCPD at 208 V, 3-phase) across standard distribution busbars.

| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **200A Bus / 200A Main (208V)** | 40 A | 45 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **400A Bus / 400A Main (208V)** | 80 A | 45 A | PASS (120% Commercial Busbar) |
| **600A Bus / 600A Main (208V)** | 120 A | 45 A | PASS (120% Commercial Busbar) |
| **800A Bus / 800A Main (208V)** | 160 A | 45 A | PASS (120% Commercial Busbar) |
| **1,200A Bus / 1,200A Main (208V)** | 240 A | 45 A | PASS (120% Commercial Busbar) |

## Which CEC PV Module Strings Pair With Fronius International GmbH: Fronius Symo 120-3 208-240 {208V}?

Verified cold-weather (-10 C) series module counts matched to Fronius International GmbH: Fronius Symo 120-3 208-240 {208V}'s 480 V DC ceiling.

Sampled CEC PV modules aligned within 300.0-480.0 V MPPT and 480.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 7 to 8 panels | 4.72 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 9 to 11 panels | 4.84 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 9 to 10 panels | 4.25 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 11 panels (fixed) | 2.2 kW |

## Which Competing Grid-Support Inverters Compare to Fronius International GmbH: Fronius Symo 120-3 208-240 {208V}?

Alternative CEC inverters comparable to Fronius International GmbH: Fronius Symo 120-3 208-240 {208V}, including Chint Power Systems America: CPS ECH12KTL/US {208V} (12,000 W) at 208 V, 3-phase.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Chint Power Systems America: CPS ECH12KTL/US {208V}**](https://epri-peac.com/solar-equipment/inverters/chint-power-systems-america/chint-power-systems-america-cps-ech12ktl-us-208v/) Chint Power Systems America | 12,000 W | Tie (0 W) | 208.0 V | 480.0 V | 96.63% |
| [**EcoFlow Inc: EF-PCS-24 {208V 115kW}**](https://epri-peac.com/solar-equipment/inverters/ecoflow-inc/ecoflow-inc-ef-pcs-24-208v-115kw/) EcoFlow Inc | 11,444 W | -556 W | 208.0 V | 480.0 V | 96.52% |
| [**Chint Power Systems America: CPS ECH114KTL/US {208V}**](https://epri-peac.com/solar-equipment/inverters/chint-power-systems-america/chint-power-systems-america-cps-ech114ktl-us-208v/) Chint Power Systems America | 11,350 W | -650 W | 208.0 V | 480.0 V | 96.63% |
| [**EG4 Electronics LLC: IV-13000-HYB-AW-FX-xx {208V}**](https://epri-peac.com/solar-equipment/inverters/eg4-electronics-llc/eg4-electronics-llc-iv-13000-hyb-aw-fx-xx-208v/) EG4 Electronics LLC | 11,325 W | -675 W | 208.0 V | 440.0 V | 96.79% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Fronius International GmbH: Fronius Symo 120-3 208-240 {208V}?

Check Fronius International GmbH: Fronius Symo 120-3 208-240 {208V} (12,000 W AC, 45 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 208 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on Fronius International GmbH: Fronius Symo 120-3 208-240 {208V}.

### Fronius International GmbH: Fronius Symo 120-3 208-240 {208V} Panel & Wire Spec

Size 75 C copper conductors at 8 AWG Cu on a 45 A OCPD breaker (33.3 A continuous).

### Alternative Inverter Comparison

Compare efficiency (95.81%) and MPPT window (300-480 V) directly against Chint Power Systems America: CPS ECH12KTL/US {208V} (12,000 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Fronius International GmbH: Fronius Symo 120-3 208-240 {208V} by Fronius International GmbH covering breaker sizing, MPPT limits, and 208 V, 3-phase interconnection.

### What breaker and wire size does Fronius International GmbH: Fronius Symo 120-3 208-240 {208V} require?

At 12,000 W continuous AC (208 V, 3-phase), continuous current is 33.3 A; 125% NEC 690.8/705.12 sizing requires a 45 A breaker and 8 AWG Cu (75 C) wire.

### What commercial switchgear or feeder sizing does Fronius International GmbH: Fronius Symo 120-3 208-240 {208V} require?

At 12,000 W AC and 208 V, 3-phase, continuous line current is 33.3 A, requiring a 45 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.

### How does Fronius International GmbH: Fronius Symo 120-3 208-240 {208V} compare to Chint Power Systems America: CPS ECH12KTL/US {208V}?

Fronius International GmbH: Fronius Symo 120-3 208-240 {208V} delivers 12,000 W AC at 95.81% CEC efficiency with a 480 V DC ceiling, while Chint Power Systems America: CPS ECH12KTL/US {208V} outputs 12,000 W at 208 V, 3-phase.

## Related Pages

Explore Fronius International GmbH hardware, Chint Power Systems America: CPS ECH12KTL/US {208V}, utility rates, and NEC 705.12 sizing calculators alongside Fronius International GmbH: Fronius Symo 120-3 208-240 {208V}.

[All Fronius International GmbH Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/fronius-international-gmbh/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Fronius International GmbH

- [All Fronius International GmbH Specs](https://epri-peac.com/solar-equipment/brands/fronius-international-gmbh/)
- [Fronius International GmbH: Fronius Symo Advanced 240-3 480 {480V}](https://epri-peac.com/solar-equipment/inverters/fronius-international-gmbh/fronius-international-gmbh-fronius-symo-advanced-240-3-480-480v/)
- [Fronius International GmbH: Fronius Symo Advanced 240-3 480 Lite {480V}](https://epri-peac.com/solar-equipment/inverters/fronius-international-gmbh/fronius-international-gmbh-fronius-symo-advanced-240-3-480-lite-480v/)
- [Fronius International GmbH: Fronius Symo 240-3 480 {480V}](https://epri-peac.com/solar-equipment/inverters/fronius-international-gmbh/fronius-international-gmbh-fronius-symo-240-3-480-480v/)
- [Fronius International GmbH: Fronius Symo Advanced 227-3 480 {480V}](https://epri-peac.com/solar-equipment/inverters/fronius-international-gmbh/fronius-international-gmbh-fronius-symo-advanced-227-3-480-480v/)
- [Fronius International GmbH: Fronius Symo Advanced 227-3 480 Lite {480V}](https://epri-peac.com/solar-equipment/inverters/fronius-international-gmbh/fronius-international-gmbh-fronius-symo-advanced-227-3-480-lite-480v/)