CEC Grid-Support Inverter

# FOXESS CO LTD: M1-1000-NA {240V} — CEC Inverter Specifications

Manufacturer: [**FOXESS CO LTD**](https://epri-peac.com/solar-equipment/brands/foxess-co-ltd/) Registry: **CEC Verified Engineering Specification**

FOXESS CO LTD: M1-1000-NA {240V} outputs 1,005 W AC at 240 V (4.2 A continuous, 15 A OCPD), ranking #2,242 of 2,343 CEC inverters at 95.13% efficiency with a 35-50 V MPPT window and 50 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 1,005 W

- **AC Voltage** : 240 V

- **Min PV Breaker** : 15 A (14 AWG Cu)

- **CEC Efficiency** : 95.13%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does FOXESS CO LTD: M1-1000-NA {240V} Compare Against Peer CEC Listings?

Breaker sizing (15 A), 14 AWG Cu wire rules, and DC input limits for FOXESS CO LTD: M1-1000-NA {240V}.

Classified as a grid-tied PV inverter (active in CEC directory), FOXESS CO LTD: M1-1000-NA {240V} requires 5.2 A design capacity -> 15 A breaker using 14 AWG Cu copper at 75 C terminals. Weighted efficiency sits at 95.13% (-1.69 pts vs overall CEC median) across 2,343 CEC models, while requires a 15 a breaker, passing directly inside a standard 200 a main / 200 a busbar panel (40 a limit).

## Where Does FOXESS CO LTD: M1-1000-NA {240V} Fall Across Listed CEC Models?

Output power comparison showing where FOXESS CO LTD: M1-1000-NA {240V} sits among all 2,343 CEC-listed grid-support inverters. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

## What Dataset Percentiles Define FOXESS CO LTD: M1-1000-NA {240V}?

Relative ranking of FOXESS CO LTD: M1-1000-NA {240V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

## What Do the Dataset Ranks Show for FOXESS CO LTD: M1-1000-NA {240V}?

Snapshot of FOXESS CO LTD: M1-1000-NA {240V} efficiency rank (#2,242), OCPD breaker size, MPPT span, and busbar verdict.

Eff #2,242 / 2,343

### 95.13% CEC Weighted Efficiency

-1.55 pts vs the 96.68% 240 V median; overall power rank #1,829 (1,005 W, below CEC median; higher than 21.9% of peers).

NEC 705.12 Check

### 15 A Required Backfeed OCPD

125% x 4.2 A = 5.2 A -> 15 A standard OCPD using 14 AWG Cu (75 C).

MPPT Window

### 35 V - 50 V (Max 50 V DC)

Tracking span of 15.0 V; active in CEC directory (grid-tied PV inverter).

Panel Fit (240V)

### PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 1005.0W / 240 V -> 4.2 A | Breaker >= 1.25 * 4.2 = 5.2 A -> 15 A

CEC Inverters.csv for FOXESS CO LTD: M1-1000-NA {240V}: Paco=1005.0 W, Vac=240 V, Vdcmax=50.0 V, Eff=95.13%.

**Result:** Min 15 A breaker & 14 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

## What Are the Published CEC Specifications for FOXESS CO LTD: M1-1000-NA {240V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for FOXESS CO LTD: M1-1000-NA {240V}. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Official California Energy Commission (NREL SAM) test parameters for FOXESS CO LTD: M1-1000-NA {240V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 1,005 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 50 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 35 V - 50 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 25.1545 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 95.13% | Calculated AC/DC conversion ratio from CEC test protocol |
| **Inverter Topology** | Hybrid: No (Grid-Tied PV) | CEC Solar Equipment List grid-support certification |

## Can a Residential Panel Meet 120% Busbar Limits for FOXESS CO LTD: M1-1000-NA {240V}?

NEC 705.12(B)(3)(2) backfeed compliance table for FOXESS CO LTD: M1-1000-NA {240V} at 240 V. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Evaluates FOXESS CO LTD: M1-1000-NA {240V} (15 A required OCPD at 240 V) across standard distribution busbars.

| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **100A Bus / 100A Main** | 20 A | 15 A | PASS (120% Rule) |
| **150A Bus / 150A Main** | 30 A | 15 A | PASS (120% Rule) |
| **200A Bus / 200A Main** | 40 A | 15 A | PASS (120% Rule) |
| **200A Bus / 175A Main** | 65 A | 15 A | PASS (120% Rule) |
| **225A Bus / 200A Main** | 70 A | 15 A | PASS (120% Rule) |

## Which CEC PV Module Strings Pair With FOXESS CO LTD: M1-1000-NA {240V}?

Minimum and maximum series solar module strings fitting FOXESS CO LTD: M1-1000-NA {240V} MPPT and 50 V limits.

Sampled CEC PV modules aligned within 35.0-50.0 V MPPT and 50.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 1 panel (micro/module) | 0.44 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 1 panel (micro/module) | 0.42 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 1 panel (micro/module) | 0.2 kW |
| [**Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-0-270TW**](https://epri-peac.com/solar-equipment/modules/hanwha-qcells-qidong-co-ltd/hanwha-qcells-qidong-co-ltd-hsl60p6-pb-0-270tw/) | 270.0 W | 42.56 V | 1 panel (micro/module) | 0.27 kW |

## Which Competing Grid-Support Inverters Compare to FOXESS CO LTD: M1-1000-NA {240V}?

Peer 240 V CEC inverters near 1,005 W AC output such as Cherry Solution Co Ltd: CMI-1000S-SA {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Cherry Solution Co Ltd: CMI-1000S-SA {240V}**](https://epri-peac.com/solar-equipment/inverters/cherry-solution-co-ltd/cherry-solution-co-ltd-cmi-1000s-sa-240v/) Cherry Solution Co Ltd | 1,062 W | +57 W | 240.0 V | 50.0 V | 96.33% |
| [**Cherry Solution Co Ltd: CMI-1000S-WA {240V}**](https://epri-peac.com/solar-equipment/inverters/cherry-solution-co-ltd/cherry-solution-co-ltd-cmi-1000s-wa-240v/) Cherry Solution Co Ltd | 1,062 W | +57 W | 240.0 V | 50.0 V | 96.33% |
| [**Altenergy Power System Inc: DS3-H {240V}**](https://epri-peac.com/solar-equipment/inverters/altenergy-power-system-inc/altenergy-power-system-inc-ds3-h-240v/) Altenergy Power System Inc | 1,068 W | +63 W | 240.0 V | 43.0 V | 96.73% |
| [**Anker Innovations Limited: MI80H {240V}**](https://epri-peac.com/solar-equipment/inverters/anker-innovations-limited/anker-innovations-limited-mi80h-240v/) Anker Innovations Limited | 1,068 W | +63 W | 240.0 V | 43.0 V | 96.73% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for FOXESS CO LTD: M1-1000-NA {240V}?

Check FOXESS CO LTD: M1-1000-NA {240V} (1,005 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Requires a 15 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 50 V DC on FOXESS CO LTD: M1-1000-NA {240V}.

### FOXESS CO LTD: M1-1000-NA {240V} Panel & Wire Spec

Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (4.2 A continuous).

### Alternative Inverter Comparison

Compare efficiency (95.13%) and MPPT window (35-50 V) directly against Cherry Solution Co Ltd: CMI-1000S-SA {240V} (1,062 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for FOXESS CO LTD: M1-1000-NA {240V} by FOXESS CO LTD covering breaker sizing, MPPT limits, and 240 V interconnection.

### What breaker and wire size does FOXESS CO LTD: M1-1000-NA {240V} require?

At 1,005 W continuous AC (240 V), continuous current is 4.2 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.

### Does FOXESS CO LTD: M1-1000-NA {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 15 A at 240 V means PASS (120% Rule).

### How does FOXESS CO LTD: M1-1000-NA {240V} compare to Cherry Solution Co Ltd: CMI-1000S-SA {240V}?

FOXESS CO LTD: M1-1000-NA {240V} delivers 1,005 W AC at 95.13% CEC efficiency with a 50 V DC ceiling, while Cherry Solution Co Ltd: CMI-1000S-SA {240V} outputs 1,062 W at 240 V.

## Related Pages

Explore FOXESS CO LTD hardware, Cherry Solution Co Ltd: CMI-1000S-SA {240V}, utility rates, and NEC 705.12 sizing calculators alongside FOXESS CO LTD: M1-1000-NA {240V}.

[All FOXESS CO LTD Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/foxess-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From FOXESS CO LTD

- [All FOXESS CO LTD Specs](https://epri-peac.com/solar-equipment/brands/foxess-co-ltd/)
- [FOXESS CO LTD: H1-114-US {240V}](https://epri-peac.com/solar-equipment/inverters/foxess-co-ltd/foxess-co-ltd-h1-114-us-240v/)
- [FOXESS CO LTD: AC1-114-US {240V}](https://epri-peac.com/solar-equipment/inverters/foxess-co-ltd/foxess-co-ltd-ac1-114-us-240v/)
- [FOXESS CO LTD: AIO-H1-114-US {240V}](https://epri-peac.com/solar-equipment/inverters/foxess-co-ltd/foxess-co-ltd-aio-h1-114-us-240v/)
- [FOXESS CO LTD: AIO-AC1-114-US {240V}](https://epri-peac.com/solar-equipment/inverters/foxess-co-ltd/foxess-co-ltd-aio-ac1-114-us-240v/)
- [FOXESS CO LTD: H1-96-US {240V}](https://epri-peac.com/solar-equipment/inverters/foxess-co-ltd/foxess-co-ltd-h1-96-us-240v/)