CEC Grid-Support Inverter

# FOXESS CO LTD: AIO-H1-38-US {240V} — CEC Inverter Specifications

Manufacturer: [**FOXESS CO LTD**](https://epri-peac.com/solar-equipment/brands/foxess-co-ltd/) Registry: **CEC Verified Engineering Specification**

FOXESS CO LTD: AIO-H1-38-US {240V} outputs 3,797 W AC at 240 V (15.8 A continuous, 20 A OCPD), ranking #841 of 2,343 CEC inverters at 97.14% efficiency with a 204-500 V MPPT window and 500 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 3,797 W

- **AC Voltage** : 240 V

- **Min PV Breaker** : 20 A (12 AWG Cu)

- **CEC Efficiency** : 97.14%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does FOXESS CO LTD: AIO-H1-38-US {240V} Compare Against Peer CEC Listings?

Breaker sizing (20 A), 12 AWG Cu wire rules, and DC input limits for FOXESS CO LTD: AIO-H1-38-US {240V}.

For NEC 705.12 solar interconnection, FOXESS CO LTD: AIO-H1-38-US {240V} outputs 15.8 A continuous AC at 240 V and needs a 20 A backfeed breaker on 12 AWG Cu (75 C). Requires a 20 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit). Conversion efficiency scores 97.14% (#841 of 2,343, +0.32 pts vs overall CEC median).

## Where Does FOXESS CO LTD: AIO-H1-38-US {240V} Fall Across Listed CEC Models?

Output power comparison showing where FOXESS CO LTD: AIO-H1-38-US {240V} sits among all 2,343 CEC-listed grid-support inverters. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

## What Dataset Percentiles Define FOXESS CO LTD: AIO-H1-38-US {240V}?

Relative ranking of FOXESS CO LTD: AIO-H1-38-US {240V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

## What Do the Dataset Ranks Show for FOXESS CO LTD: AIO-H1-38-US {240V}?

Snapshot of FOXESS CO LTD: AIO-H1-38-US {240V} efficiency rank (#841), OCPD breaker size, MPPT span, and busbar verdict.

Eff #841 / 2,343

### 97.14% CEC Weighted Efficiency

+0.46 pts vs the 96.68% 240 V median; overall power rank #1,671 (3,797 W, below CEC median; higher than 28.7% of peers).

NEC 705.12 Check

### 20 A Required Backfeed OCPD

125% x 15.8 A = 19.8 A -> 20 A standard OCPD using 12 AWG Cu (75 C).

MPPT Window

### 204 V - 500 V (Max 500 V DC)

Tracking span of 296.0 V; active in CEC directory (hybrid battery-capable inverter).

Panel Fit (240V)

### PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 3797.2W / 240 V -> 15.8 A | Breaker >= 1.25 * 15.8 = 19.8 A -> 20 A

CEC Inverters.csv for FOXESS CO LTD: AIO-H1-38-US {240V}: Paco=3797.2 W, Vac=240 V, Vdcmax=500.0 V, Eff=97.14%.

**Result:** Min 20 A breaker & 12 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

## What Are the Published CEC Specifications for FOXESS CO LTD: AIO-H1-38-US {240V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for FOXESS CO LTD: AIO-H1-38-US {240V}. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Official California Energy Commission (NREL SAM) test parameters for FOXESS CO LTD: AIO-H1-38-US {240V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 3,797 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 500 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 204 V - 500 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 10.287 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 97.14% | Calculated AC/DC conversion ratio from CEC test protocol |
| **Inverter Topology** | Hybrid: Yes (Battery Capable) | CEC Solar Equipment List grid-support certification |

## Can a Residential Panel Meet 120% Busbar Limits for FOXESS CO LTD: AIO-H1-38-US {240V}?

NEC 705.12(B)(3)(2) backfeed compliance table for FOXESS CO LTD: AIO-H1-38-US {240V} at 240 V. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Evaluates FOXESS CO LTD: AIO-H1-38-US {240V} (20 A required OCPD at 240 V) across standard distribution busbars.

| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **100A Bus / 100A Main** | 20 A | 20 A | PASS (120% Rule) |
| **150A Bus / 150A Main** | 30 A | 20 A | PASS (120% Rule) |
| **200A Bus / 200A Main** | 40 A | 20 A | PASS (120% Rule) |
| **200A Bus / 175A Main** | 65 A | 20 A | PASS (120% Rule) |
| **225A Bus / 200A Main** | 70 A | 20 A | PASS (120% Rule) |

## Which CEC PV Module Strings Pair With FOXESS CO LTD: AIO-H1-38-US {240V}?

Minimum and maximum series solar module strings fitting FOXESS CO LTD: AIO-H1-38-US {240V} MPPT and 500 V limits.

Sampled CEC PV modules aligned within 204.0-500.0 V MPPT and 500.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 5 to 8 panels | 4.72 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 7 to 11 panels | 4.84 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 6 to 11 panels | 4.67 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 8 to 12 panels | 2.4 kW |

## Which Competing Grid-Support Inverters Compare to FOXESS CO LTD: AIO-H1-38-US {240V}?

Peer 240 V CEC inverters near 3,797 W AC output such as ABB: PVI-38-OUTD-S-US-A {240V}. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**ABB: PVI-38-OUTD-S-US-A {240V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-pvi-38-outd-s-us-a-240v/) ABB | 3,800 W | +3 W | 240.0 V | 480.0 V | 96.2% |
| [**ABB: PVI-38-OUTD-S-US-Z-A {240V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-pvi-38-outd-s-us-z-a-240v/) ABB | 3,800 W | +3 W | 240.0 V | 480.0 V | 96.2% |
| [**ABB: PVI-38-OUTD-S-US-Z-M-A {240V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-pvi-38-outd-s-us-z-m-a-240v/) ABB | 3,800 W | +3 W | 240.0 V | 480.0 V | 96.2% |
| [**ABB: UNO-DM-38-TL-PLUS-US-SB-RA {240V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-uno-dm-38-tl-plus-us-sb-ra-240v/) ABB | 3,800 W | +3 W | 240.0 V | 480.0 V | 96.39% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for FOXESS CO LTD: AIO-H1-38-US {240V}?

Check FOXESS CO LTD: AIO-H1-38-US {240V} (3,797 W AC, 20 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Requires a 20 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 500 V DC on FOXESS CO LTD: AIO-H1-38-US {240V}.

### FOXESS CO LTD: AIO-H1-38-US {240V} Panel & Wire Spec

Size 75 C copper conductors at 12 AWG Cu on a 20 A OCPD breaker (15.8 A continuous).

### Alternative Inverter Comparison

Compare efficiency (97.14%) and MPPT window (204-500 V) directly against ABB: PVI-38-OUTD-S-US-A {240V} (3,800 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for FOXESS CO LTD: AIO-H1-38-US {240V} by FOXESS CO LTD covering breaker sizing, MPPT limits, and 240 V interconnection.

### What breaker and wire size does FOXESS CO LTD: AIO-H1-38-US {240V} require?

At 3,797 W continuous AC (240 V), continuous current is 15.8 A; 125% NEC 690.8/705.12 sizing requires a 20 A breaker and 12 AWG Cu (75 C) wire.

### Does FOXESS CO LTD: AIO-H1-38-US {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 20 A at 240 V means PASS (120% Rule).

### How does FOXESS CO LTD: AIO-H1-38-US {240V} compare to ABB: PVI-38-OUTD-S-US-A {240V}?

FOXESS CO LTD: AIO-H1-38-US {240V} delivers 3,797 W AC at 97.14% CEC efficiency with a 500 V DC ceiling, while ABB: PVI-38-OUTD-S-US-A {240V} outputs 3,800 W at 240 V.

## Related Pages

Explore FOXESS CO LTD hardware, ABB: PVI-38-OUTD-S-US-A {240V}, utility rates, and NEC 705.12 sizing calculators alongside FOXESS CO LTD: AIO-H1-38-US {240V}.

[All FOXESS CO LTD Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/foxess-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From FOXESS CO LTD

- [All FOXESS CO LTD Specs](https://epri-peac.com/solar-equipment/brands/foxess-co-ltd/)
- [FOXESS CO LTD: H1-114-US {240V}](https://epri-peac.com/solar-equipment/inverters/foxess-co-ltd/foxess-co-ltd-h1-114-us-240v/)
- [FOXESS CO LTD: AC1-114-US {240V}](https://epri-peac.com/solar-equipment/inverters/foxess-co-ltd/foxess-co-ltd-ac1-114-us-240v/)
- [FOXESS CO LTD: AIO-H1-114-US {240V}](https://epri-peac.com/solar-equipment/inverters/foxess-co-ltd/foxess-co-ltd-aio-h1-114-us-240v/)
- [FOXESS CO LTD: AIO-AC1-114-US {240V}](https://epri-peac.com/solar-equipment/inverters/foxess-co-ltd/foxess-co-ltd-aio-ac1-114-us-240v/)
- [FOXESS CO LTD: H1-96-US {240V}](https://epri-peac.com/solar-equipment/inverters/foxess-co-ltd/foxess-co-ltd-h1-96-us-240v/)