title: "EPC Power Corp: HY LC12/6-7 {480V} Inverter (220,033W)"
url: https://epri-peac.com/solar-equipment/inverters/epc-power-corp/epc-power-corp-hy-lc12-6-7-480v/
description: "CEC specs for EPC Power Corp: HY LC12/6-7 {480V}: 220,033W AC, 480V, 400A OCPD, and NEC 705.12 checks. Verified US government and CEC engineering data."
---

CEC Grid-Support Inverter

# EPC Power Corp: HY LC12/6-7 {480V} — CEC Inverter Specifications

Manufacturer: [**EPC Power Corp**](https://epri-peac.com/solar-equipment/brands/epc-power-corp/) Registry: **CEC Verified Engineering Specification**

EPC Power Corp: HY LC12/6-7 {480V} outputs 220,033 W AC at 480 V, 3-phase (264.7 A continuous, 400 A OCPD), ranking #2,164 of 2,343 CEC inverters at 95.51% efficiency with a 455-600 V MPPT window and 600 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 220,033 W

- **AC Voltage** : 480 V, 3-phase

- **Min PV Breaker** : 400 A (parallel Cu feeders)

- **CEC Efficiency** : 95.51%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does EPC Power Corp: HY LC12/6-7 {480V} Compare Against Peer CEC Listings?

Breaker sizing (400 A), parallel Cu feeders wire rules, and DC input limits for EPC Power Corp: HY LC12/6-7 {480V}.

Classified as a hybrid battery-capable inverter (active in CEC directory), EPC Power Corp: HY LC12/6-7 {480V} requires 330.9 A design capacity -> 400 A breaker using parallel Cu feeders copper at 75 C terminals. Weighted efficiency sits at 95.51% (-1.31 pts vs overall CEC median) across 2,343 CEC models, while commercial 480 v, 3-phase switchgear interconnection uses 1,200a bus / 1,200a main (480v) or nec 705.11 supply-side tap.

## Where Does EPC Power Corp: HY LC12/6-7 {480V} Fall Across Listed CEC Models?

Output power comparison showing where EPC Power Corp: HY LC12/6-7 {480V} sits among all 2,343 CEC-listed grid-support inverters.

## What Dataset Percentiles Define EPC Power Corp: HY LC12/6-7 {480V}?

Relative ranking of EPC Power Corp: HY LC12/6-7 {480V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

## What Do the Dataset Ranks Show for EPC Power Corp: HY LC12/6-7 {480V}?

Snapshot of EPC Power Corp: HY LC12/6-7 {480V} efficiency rank (#2,164), OCPD breaker size, MPPT span, and busbar verdict.

Eff #2,164 / 2,343

### 95.51% CEC Weighted Efficiency

-2.51 pts vs the 98.02% 480 V median; overall power rank #242 (220,033 W, top 10.3%; higher than 89.7% of peers).

NEC 705.12 Check

### 400 A Required Backfeed OCPD

125% x 264.7 A = 330.9 A -> 400 A standard OCPD using parallel Cu feeders (75 C).

MPPT Window

### 455 V - 600 V (Max 600 V DC)

Tracking span of 145.0 V; active in CEC directory (hybrid battery-capable inverter).

Commercial / 3-Phase Fit

### Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 480 V, 3-phase switchgear (200A Bus / 200A Main (480V) to 1,200A Bus / 1,200A Main (480V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 220033.0W / 480 V 3-phase -> 264.7 A | Breaker >= 1.25 * 264.7 = 330.9 A -> 400 A

CEC Inverters.csv for EPC Power Corp: HY LC12/6-7 {480V}: Paco=220033.0 W, Vac=480 V, Vdcmax=600.0 V, Eff=95.51%.

**Result:** Min 400 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (480V): Supply-Side Tap (705.11) / Dedicated Switchboard.

## What Are the Published CEC Specifications for EPC Power Corp: HY LC12/6-7 {480V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for EPC Power Corp: HY LC12/6-7 {480V}.

Official California Energy Commission (NREL SAM) test parameters for EPC Power Corp: HY LC12/6-7 {480V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 220,033 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 480 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 600 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 455 V - 600 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 485.023 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 95.51% | Calculated AC/DC conversion ratio from CEC test protocol |
| **Inverter Topology** | Hybrid: Yes (Battery Capable) | CEC Solar Equipment List grid-support certification |

## What Switchgear Limits Apply to EPC Power Corp: HY LC12/6-7 {480V} (480 V, 3-phase)?

NEC 705.12(B)(3)(2) backfeed compliance table for EPC Power Corp: HY LC12/6-7 {480V} at 480 V, 3-phase.

Evaluates EPC Power Corp: HY LC12/6-7 {480V} (400 A required OCPD at 480 V, 3-phase) across standard distribution busbars.

| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **200A Bus / 200A Main (480V)** | 40 A | 400 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **400A Bus / 400A Main (480V)** | 80 A | 400 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **600A Bus / 600A Main (480V)** | 120 A | 400 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **800A Bus / 800A Main (480V)** | 160 A | 400 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **1,200A Bus / 1,200A Main (480V)** | 240 A | 400 A | Supply-Side Tap (705.11) / Dedicated Switchboard |

## Which CEC PV Module Strings Pair With EPC Power Corp: HY LC12/6-7 {480V}?

Minimum and maximum series solar module strings fitting EPC Power Corp: HY LC12/6-7 {480V} MPPT and 600 V limits.

Sampled CEC PV modules aligned within 455.0-600.0 V MPPT and 600.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 14 panels (fixed) | 6.16 kW |
| [**G-Star Pte Ltd GSN8K66T(H)740WT**](https://epri-peac.com/solar-equipment/modules/g-star-pte-ltd/g-star-pte-ltd-gsn8k66t-h-740wt/) | 740.0 W | 54.38 V | 11 panels (fixed) | 8.14 kW |

## Which Competing Grid-Support Inverters Compare to EPC Power Corp: HY LC12/6-7 {480V}?

Peer 480 V, 3-phase CEC inverters near 220,033 W AC output such as Chint Power Systems America: SCH200K-T-US-480 {480V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Chint Power Systems America: SCH200K-T-US-480 {480V}**](https://epri-peac.com/solar-equipment/inverters/chint-power-systems-america/chint-power-systems-america-sch200k-t-us-480-480v/) Chint Power Systems America | 200,000 W | -20033 W | 480.0 V | 1300.0 V | 97.72% |
| [**DYNAPOWER COMPANY LLC: MPS-250 {480V}**](https://epri-peac.com/solar-equipment/inverters/dynapower-company-llc/dynapower-company-llc-mps-250-480v/) DYNAPOWER COMPANY LLC | 248,910 W | +28877 W | 480.0 V | 600.0 V | 95.24% |
| [**DYNAPOWER COMPANY LLC: MPS-250HV {480V}**](https://epri-peac.com/solar-equipment/inverters/dynapower-company-llc/dynapower-company-llc-mps-250hv-480v/) DYNAPOWER COMPANY LLC | 249,619 W | +29586 W | 480.0 V | 830.0 V | 96.2% |
| [**Chint Power Systems America: CPS ECB125KTL-M/US-480 {480V}**](https://epri-peac.com/solar-equipment/inverters/chint-power-systems-america/chint-power-systems-america-cps-ecb125ktl-m-us-480-480v/) Chint Power Systems America | 125,000 W | -95033 W | 480.0 V | 1100.0 V | 97.2% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for EPC Power Corp: HY LC12/6-7 {480V}?

Check EPC Power Corp: HY LC12/6-7 {480V} (220,033 W AC, 400 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 600 V DC on EPC Power Corp: HY LC12/6-7 {480V}.

### EPC Power Corp: HY LC12/6-7 {480V} Panel & Wire Spec

Size 75 C copper conductors at parallel Cu feeders on a 400 A OCPD breaker (264.7 A continuous).

### Alternative Inverter Comparison

Compare efficiency (95.51%) and MPPT window (455-600 V) directly against Chint Power Systems America: SCH200K-T-US-480 {480V} (200,000 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for EPC Power Corp: HY LC12/6-7 {480V} by EPC Power Corp covering breaker sizing, MPPT limits, and 480 V, 3-phase interconnection.

### What breaker and wire size does EPC Power Corp: HY LC12/6-7 {480V} require?

At 220,033 W continuous AC (480 V, 3-phase), continuous current is 264.7 A; 125% NEC 690.8/705.12 sizing requires a 400 A breaker and parallel Cu feeders (75 C) wire.

### What commercial switchgear or feeder sizing does EPC Power Corp: HY LC12/6-7 {480V} require?

At 220,033 W AC and 480 V, 3-phase, continuous line current is 264.7 A, requiring a 400 A OCPD and 1,200A Bus / 1,200A Main (480V) or NEC 705.11 interconnection.

### How does EPC Power Corp: HY LC12/6-7 {480V} compare to Chint Power Systems America: SCH200K-T-US-480 {480V}?

EPC Power Corp: HY LC12/6-7 {480V} delivers 220,033 W AC at 95.51% CEC efficiency with a 600 V DC ceiling, while Chint Power Systems America: SCH200K-T-US-480 {480V} outputs 200,000 W at 480 V, 3-phase.

## Related Pages

Explore EPC Power Corp hardware, Chint Power Systems America: SCH200K-T-US-480 {480V}, utility rates, and NEC 705.12 sizing calculators alongside EPC Power Corp: HY LC12/6-7 {480V}.

[All EPC Power Corp Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/epc-power-corp/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From EPC Power Corp

- [All EPC Power Corp Specs](https://epri-peac.com/solar-equipment/brands/epc-power-corp/)
- [EPC Power Corp: 50-100181 {690V}](https://epri-peac.com/solar-equipment/inverters/epc-power-corp/epc-power-corp-50-100181-690v/)
- [EPC Power Corp: 50-100100 {690V}](https://epri-peac.com/solar-equipment/inverters/epc-power-corp/epc-power-corp-50-100100-690v/)
- [EPC Power Corp: 50-100181 {600V}](https://epri-peac.com/solar-equipment/inverters/epc-power-corp/epc-power-corp-50-100181-600v/)
- [EPC Power Corp: 50-100181 {480V}](https://epri-peac.com/solar-equipment/inverters/epc-power-corp/epc-power-corp-50-100181-480v/)
- [EPC Power Corp: 50-100100 {480V}](https://epri-peac.com/solar-equipment/inverters/epc-power-corp/epc-power-corp-50-100100-480v/)