CEC Grid-Support Inverter

# EPC Power Corp: 50-100181 {690V} — CEC Inverter Specifications

Manufacturer: [**EPC Power Corp**](https://epri-peac.com/solar-equipment/brands/epc-power-corp/) Registry: **CEC Verified Engineering Specification**

EPC Power Corp: 50-100181 {690V} outputs 1,504,900 W AC at 690 V, 3-phase (1259.2 A continuous, 1,600 A OCPD), ranking #302 of 2,343 CEC inverters at 98.09% efficiency with a 1,100-1,500 V MPPT window and 1,500 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 1,504,900 W

- **AC Voltage** : 690 V, 3-phase

- **Min PV Breaker** : 1,600 A (parallel Cu feeders)

- **CEC Efficiency** : 98.09%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does EPC Power Corp: 50-100181 {690V} Compare Against Peer CEC Listings?

CEC efficiency rank (#302), 1,100-1,500 V MPPT tracking, and panel fit for EPC Power Corp: 50-100181 {690V}. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

EPC Power Corp: 50-100181 {690V} from EPC Power Corp outputs 1259.2 A continuous AC at 690 V, 3-phase (1,504,900 W AC, rank #132). Paired with parallel Cu feeders conductors and a 1,600 A OCPD, its 98.09% CEC efficiency compares closely with Power Electronics: FS1275CU15 {690V} (1,389,080 W). Keep NEC 690.7 winter string Voc below 1,500 V DC.

## Where Does EPC Power Corp: 50-100181 {690V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting EPC Power Corp: 50-100181 {690V} at 1,504,900 W continuous AC output. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

## What Dataset Percentiles Define EPC Power Corp: 50-100181 {690V}?

Dataset percentiles comparing EPC Power Corp: 50-100181 {690V} against 2,343 certified grid-support inverters nationwide. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

## What Do the Dataset Ranks Show for EPC Power Corp: 50-100181 {690V}?

Engineering highlights for EPC Power Corp: 50-100181 {690V} covering efficiency, parallel Cu feeders feeder, and panel compatibility. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Eff #302 / 2,343

### 98.09% CEC Weighted Efficiency

-0.08 pts vs the 98.17% 690 V median; overall power rank #132 (1,504,900 W, top 5.6%; higher than 94.4% of peers).

NEC 705.12 Check

### 1,600 A Required Backfeed OCPD

125% x 1259.2 A = 1574.0 A -> 1,600 A standard OCPD using parallel Cu feeders (75 C).

MPPT Window

### 1,100 V - 1,500 V (Max 1,500 V DC)

Tracking span of 400.0 V; listed since 2024-09-03 (hybrid battery-capable inverter).

Commercial / 3-Phase Fit

### Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 690 V, 3-phase switchgear (200A Bus / 200A Main (690V) to 1,200A Bus / 1,200A Main (690V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 1504900.0W / 690 V 3-phase -> 1259.2 A | Breaker >= 1.25 * 1259.2 = 1574.0 A -> 1,600 A

CEC Inverters.csv for EPC Power Corp: 50-100181 {690V}: Paco=1504900.0 W, Vac=690 V, Vdcmax=1500.0 V, Eff=98.09%.

**Result:** Min 1,600 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (690V): Supply-Side Tap (705.11) / Dedicated Switchboard.

## What Are the Published CEC Specifications for EPC Power Corp: 50-100181 {690V}?

California Energy Commission Solar Equipment List parameters for EPC Power Corp: 50-100181 {690V} (hybrid battery-capable inverter) interconnection. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Official California Energy Commission (NREL SAM) test parameters for EPC Power Corp: 50-100181 {690V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 1,504,900 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 690 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 1,500 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 1,100 V - 1,500 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 1153.57 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 98.09% | Calculated AC/DC conversion ratio from CEC test protocol |
| **CEC Listing Date & Hybrid** | 2024-09-03 / Hybrid: Yes (Battery Capable) | Utility interconnection approval metadata |

## What Switchgear Limits Apply to EPC Power Corp: 50-100181 {690V} (690 V, 3-phase)?

Panelboard and switchgear backfeed allowances for EPC Power Corp: 50-100181 {690V} (1,600 A OCPD). Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Evaluates EPC Power Corp: 50-100181 {690V} (1600 A required OCPD at 690 V, 3-phase) across standard distribution busbars.

| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **200A Bus / 200A Main (690V)** | 40 A | 1,600 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **400A Bus / 400A Main (690V)** | 80 A | 1,600 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **600A Bus / 600A Main (690V)** | 120 A | 1,600 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **800A Bus / 800A Main (690V)** | 160 A | 1,600 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **1,200A Bus / 1,200A Main (690V)** | 240 A | 1,600 A | Supply-Side Tap (705.11) / Dedicated Switchboard |

## Which CEC PV Module Strings Pair With EPC Power Corp: 50-100181 {690V}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for EPC Power Corp: 50-100181 {690V}. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Sampled CEC PV modules aligned within 1100.0-1500.0 V MPPT and 1500.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 26 panels (fixed) | 15.34 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 33 to 35 panels | 15.4 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 32 to 33 panels | 14.03 kW |
| [**Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-515**](https://epri-peac.com/solar-equipment/modules/chint-new-energy-technology-co-ltd/chint-new-energy-technology-co-ltd-chsm72m-dg-f-bh-515/) | 515.0 W | 53.76 V | 27 panels (fixed) | 13.9 kW |

## Which Competing Grid-Support Inverters Compare to EPC Power Corp: 50-100181 {690V}?

Four alternative CEC inverters matched to EPC Power Corp: 50-100181 {690V} (1,504,900 W AC), led by Power Electronics: FS1275CU15 {690V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Power Electronics: FS1275CU15 {690V}**](https://epri-peac.com/solar-equipment/inverters/power-electronics/power-electronics-fs1275cu15-690v/) Power Electronics | 1,389,080 W | -115820 W | 690.0 V | 1200.0 V | 97.72% |
| [**Shenzhen Sinexcel Electric Co Ltd: PWS1-1725KTL-H-NA-8M1 {690V}**](https://epri-peac.com/solar-equipment/inverters/shenzhen-sinexcel-electric-co-ltd/shenzhen-sinexcel-electric-co-ltd-pws1-1725ktl-h-na-8m1-690v/) Shenzhen Sinexcel Electric Co Ltd | 1,708,180 W | +203280 W | 690.0 V | 1450.0 V | 93.44% |
| [**INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1800TL U B690 {690V}**](https://epri-peac.com/solar-equipment/inverters/ingeteam-power-technology-sa/ingeteam-power-technology-sa-ingecon-sun-1800tl-u-b690-690v/) INGETEAM POWER TECHNOLOGY SA | 1,300,644 W | -204256 W | 690.0 V | 1200.0 V | 97.34% |
| [**Shenzhen Sinexcel Electric Co Ltd: PWS1-1725KTL-H-NA-8M8 {690V}**](https://epri-peac.com/solar-equipment/inverters/shenzhen-sinexcel-electric-co-ltd/shenzhen-sinexcel-electric-co-ltd-pws1-1725ktl-h-na-8m8-690v/) Shenzhen Sinexcel Electric Co Ltd | 1,710,710 W | +205810 W | 690.0 V | 1450.0 V | 92.8% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for EPC Power Corp: 50-100181 {690V}?

Check EPC Power Corp: 50-100181 {690V} (1,504,900 W AC, 1,600 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 690 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (690V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,500 V DC on EPC Power Corp: 50-100181 {690V}.

### EPC Power Corp: 50-100181 {690V} Panel & Wire Spec

Size 75 C copper conductors at parallel Cu feeders on a 1,600 A OCPD breaker (1259.2 A continuous).

### Alternative Inverter Comparison

Compare efficiency (98.09%) and MPPT window (1,100-1,500 V) directly against Power Electronics: FS1275CU15 {690V} (1,389,080 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for EPC Power Corp: 50-100181 {690V} by EPC Power Corp covering breaker sizing, MPPT limits, and 690 V, 3-phase interconnection.

### What breaker and wire size does EPC Power Corp: 50-100181 {690V} require?

At 1,504,900 W continuous AC (690 V, 3-phase), continuous current is 1259.2 A; 125% NEC 690.8/705.12 sizing requires a 1,600 A breaker and parallel Cu feeders (75 C) wire.

### What commercial switchgear or feeder sizing does EPC Power Corp: 50-100181 {690V} require?

At 1,504,900 W AC and 690 V, 3-phase, continuous line current is 1259.2 A, requiring a 1,600 A OCPD and 1,200A Bus / 1,200A Main (690V) or NEC 705.11 interconnection.

### How does EPC Power Corp: 50-100181 {690V} compare to Power Electronics: FS1275CU15 {690V}?

EPC Power Corp: 50-100181 {690V} delivers 1,504,900 W AC at 98.09% CEC efficiency with a 1,500 V DC ceiling, while Power Electronics: FS1275CU15 {690V} outputs 1,389,080 W at 690 V, 3-phase.

## Related Pages

Explore EPC Power Corp hardware, Power Electronics: FS1275CU15 {690V}, utility rates, and NEC 705.12 sizing calculators alongside EPC Power Corp: 50-100181 {690V}.

[All EPC Power Corp Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/epc-power-corp/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From EPC Power Corp

- [All EPC Power Corp Specs](https://epri-peac.com/solar-equipment/brands/epc-power-corp/)
- [EPC Power Corp: 50-100100 {690V}](https://epri-peac.com/solar-equipment/inverters/epc-power-corp/epc-power-corp-50-100100-690v/)
- [EPC Power Corp: 50-100181 {600V}](https://epri-peac.com/solar-equipment/inverters/epc-power-corp/epc-power-corp-50-100181-600v/)
- [EPC Power Corp: 50-100181 {480V}](https://epri-peac.com/solar-equipment/inverters/epc-power-corp/epc-power-corp-50-100181-480v/)
- [EPC Power Corp: 50-100100 {480V}](https://epri-peac.com/solar-equipment/inverters/epc-power-corp/epc-power-corp-50-100100-480v/)
- [EPC Power Corp: 50-200100 {850V}](https://epri-peac.com/solar-equipment/inverters/epc-power-corp/epc-power-corp-50-200100-850v/)