title: "Enphase Energy Inc: IQ8X-80-M-US Inverter (380W)"
url: https://epri-peac.com/solar-equipment/inverters/enphase-energy-inc/enphase-energy-inc-iq8x-80-m-us-240v/
description: "CEC specs for Enphase Energy Inc: IQ8X-80-M-US {240V}: 380W AC, 240V, 15A OCPD, and NEC 705.12 checks. Verified US government and CEC engineering data."
---

CEC Grid-Support Inverter

# Enphase Energy Inc: IQ8X-80-M-US {240V} — CEC Inverter Specifications

Manufacturer: [**Enphase Energy Inc**](https://epri-peac.com/solar-equipment/brands/enphase-energy-inc/) Registry: **CEC Verified Engineering Specification**

Enphase Energy Inc: IQ8X-80-M-US {240V} outputs 380 W AC at 240 V (1.6 A continuous, 15 A OCPD), ranking #1,520 of 2,343 CEC inverters at 96.52% efficiency with a 43-60 V MPPT window and 60 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 380 W

- **AC Voltage** : 240 V

- **Min PV Breaker** : 15 A (14 AWG Cu)

- **CEC Efficiency** : 96.52%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Enphase Energy Inc: IQ8X-80-M-US {240V} Compare Against Peer CEC Listings?

Breaker sizing (15 A), 14 AWG Cu wire rules, and DC input limits for Enphase Energy Inc: IQ8X-80-M-US {240V}.

Classified as a grid-tied PV inverter (listed since 2025-06-23), Enphase Energy Inc: IQ8X-80-M-US {240V} requires 2.0 A design capacity -> 15 A breaker using 14 AWG Cu copper at 75 C terminals. Weighted efficiency sits at 96.52% (-0.30 pts vs overall CEC median) across 2,343 CEC models, while module-level microinverter output eliminates high-voltage dc rooftop strings and connects via a 240v ac trunk circuit.

## Where Does Enphase Energy Inc: IQ8X-80-M-US {240V} Fall Across Listed CEC Models?

Output power comparison showing where Enphase Energy Inc: IQ8X-80-M-US {240V} sits among all 2,343 CEC-listed grid-support inverters. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

## What Dataset Percentiles Define Enphase Energy Inc: IQ8X-80-M-US {240V}?

Relative ranking of Enphase Energy Inc: IQ8X-80-M-US {240V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

## What Do the Dataset Ranks Show for Enphase Energy Inc: IQ8X-80-M-US {240V}?

Snapshot of Enphase Energy Inc: IQ8X-80-M-US {240V} efficiency rank (#1,520), OCPD breaker size, MPPT span, and busbar verdict.

Eff #1,520 / 2,343

### 96.52% CEC Weighted Efficiency

-0.16 pts vs the 96.68% 240 V median; overall power rank #2,008 (380 W, below CEC median; higher than 14.0% of peers).

NEC 705.12 Check

### 15 A Required Backfeed OCPD

125% x 1.6 A = 2.0 A -> 15 A standard OCPD using 14 AWG Cu (75 C).

MPPT Window

### 43 V - 60 V (Max 60 V DC)

Tracking span of 17.0 V; listed since 2025-06-23 (grid-tied PV inverter).

Panel Fit (240V)

### PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 380.0W / 240 V -> 1.6 A | Breaker >= 1.25 * 1.6 = 2.0 A -> 15 A

CEC Inverters.csv for Enphase Energy Inc: IQ8X-80-M-US {240V}: Paco=380.0 W, Vac=240 V, Vdcmax=60.0 V, Eff=96.52%.

**Result:** Min 15 A breaker & 14 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

## What Are the Published CEC Specifications for Enphase Energy Inc: IQ8X-80-M-US {240V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Enphase Energy Inc: IQ8X-80-M-US {240V}. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Official California Energy Commission (NREL SAM) test parameters for Enphase Energy Inc: IQ8X-80-M-US {240V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 380 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 60 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 43 V - 60 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 7.64488 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 96.52% | Calculated AC/DC conversion ratio from CEC test protocol |
| **CEC Listing Date & Hybrid** | 2025-06-23 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |

## Can a Residential Panel Meet 120% Busbar Limits for Enphase Energy Inc: IQ8X-80-M-US {240V}?

NEC 705.12(B)(3)(2) backfeed compliance table for Enphase Energy Inc: IQ8X-80-M-US {240V} at 240 V. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Evaluates Enphase Energy Inc: IQ8X-80-M-US {240V} (15 A required OCPD at 240 V) across standard distribution busbars.

| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **100A Bus / 100A Main** | 20 A | 15 A | PASS (120% Rule) |
| **150A Bus / 150A Main** | 30 A | 15 A | PASS (120% Rule) |
| **200A Bus / 200A Main** | 40 A | 15 A | PASS (120% Rule) |
| **200A Bus / 175A Main** | 65 A | 15 A | PASS (120% Rule) |
| **225A Bus / 200A Main** | 70 A | 15 A | PASS (120% Rule) |

## Which CEC PV Module Strings Pair With Enphase Energy Inc: IQ8X-80-M-US {240V}?

Minimum and maximum series solar module strings fitting Enphase Energy Inc: IQ8X-80-M-US {240V} MPPT and 60 V limits.

Sampled CEC PV modules aligned within 43.0-60.0 V MPPT and 60.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 1 panel (micro/module) | 0.59 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 1 panel (micro/module) | 0.44 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 1 panel (micro/module) | 0.42 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 1 panel (micro/module) | 0.2 kW |

## Which Competing Grid-Support Inverters Compare to Enphase Energy Inc: IQ8X-80-M-US {240V}?

Peer 240 V CEC inverters near 380 W AC output such as Aptos Solar Technology LLC: MAC-400 {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Aptos Solar Technology LLC: MAC-400 {240V}**](https://epri-peac.com/solar-equipment/inverters/aptos-solar-technology-llc/aptos-solar-technology-llc-mac-400-240v/) Aptos Solar Technology LLC | 382 W | +2 W | 240.0 V | 48.0 V | 96.52% |
| [**Aptos Solar Technology LLC: MAC-400R {240V}**](https://epri-peac.com/solar-equipment/inverters/aptos-solar-technology-llc/aptos-solar-technology-llc-mac-400r-240v/) Aptos Solar Technology LLC | 382 W | +2 W | 240.0 V | 48.0 V | 96.52% |
| [**Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V}**](https://epri-peac.com/solar-equipment/inverters/chilicon-power-llc/chilicon-power-llc-cp-250e-60-72-208-240-mc4-240v/) Chilicon Power LLC | 289 W | -91 W | 240.0 V | 32.0 V | 95.41% |
| [**Altenergy Power System Inc: YC600 {240V}**](https://epri-peac.com/solar-equipment/inverters/altenergy-power-system-inc/altenergy-power-system-inc-yc600-240v/) Altenergy Power System Inc | 550 W | +170 W | 240.0 V | 45.0 V | 96.51% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Enphase Energy Inc: IQ8X-80-M-US {240V}?

Check Enphase Energy Inc: IQ8X-80-M-US {240V} (380 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 60 V DC on Enphase Energy Inc: IQ8X-80-M-US {240V}.

### Enphase Energy Inc: IQ8X-80-M-US {240V} Panel & Wire Spec

Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (1.6 A continuous).

### Alternative Inverter Comparison

Compare efficiency (96.52%) and MPPT window (43-60 V) directly against Aptos Solar Technology LLC: MAC-400 {240V} (382 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Enphase Energy Inc: IQ8X-80-M-US {240V} by Enphase Energy Inc covering breaker sizing, MPPT limits, and 240 V interconnection.

### What breaker and wire size does Enphase Energy Inc: IQ8X-80-M-US {240V} require?

At 380 W continuous AC (240 V), continuous current is 1.6 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.

### Does Enphase Energy Inc: IQ8X-80-M-US {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 15 A at 240 V means PASS (120% Rule).

### How does Enphase Energy Inc: IQ8X-80-M-US {240V} compare to Aptos Solar Technology LLC: MAC-400 {240V}?

Enphase Energy Inc: IQ8X-80-M-US {240V} delivers 380 W AC at 96.52% CEC efficiency with a 60 V DC ceiling, while Aptos Solar Technology LLC: MAC-400 {240V} outputs 382 W at 240 V.

## Related Pages

Explore Enphase Energy Inc hardware, Aptos Solar Technology LLC: MAC-400 {240V}, utility rates, and NEC 705.12 sizing calculators alongside Enphase Energy Inc: IQ8X-80-M-US {240V}.

[All Enphase Energy Inc Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/enphase-energy-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Enphase Energy Inc

- [All Enphase Energy Inc Specs](https://epri-peac.com/solar-equipment/brands/enphase-energy-inc/)
- [Enphase Energy Inc: IQBATTERY-10C-1P-NA {240V}](https://epri-peac.com/solar-equipment/inverters/enphase-energy-inc/enphase-energy-inc-iqbattery-10c-1p-na-240v/)
- [Enphase Energy Inc: IQBATTERY-10CS-1P-NA {240V}](https://epri-peac.com/solar-equipment/inverters/enphase-energy-inc/enphase-energy-inc-iqbattery-10cs-1p-na-240v/)
- [Enphase Energy Inc: IQ8D-72-E-US {208V}](https://epri-peac.com/solar-equipment/inverters/enphase-energy-inc/enphase-energy-inc-iq8d-72-e-us-208v/)
- [Enphase Energy Inc: IQ8D-BAT-240 {240V}](https://epri-peac.com/solar-equipment/inverters/enphase-energy-inc/enphase-energy-inc-iq8d-bat-240-240v/)
- [Enphase Energy Inc: IQ8D-BAT {240V}](https://epri-peac.com/solar-equipment/inverters/enphase-energy-inc/enphase-energy-inc-iq8d-bat-240v/)