CEC Grid-Support Inverter

# Enphase Energy Inc: IQ8D-BAT-DOM {208V} — CEC Inverter Specifications

Manufacturer: [**Enphase Energy Inc**](https://epri-peac.com/solar-equipment/brands/enphase-energy-inc/) Registry: **CEC Verified Engineering Specification**

Enphase Energy Inc: IQ8D-BAT-DOM {208V} outputs 555 W AC at 208 V, commercial single-phase (2.7 A continuous, 15 A OCPD), ranking #887 of 2,343 CEC inverters at 97.1% efficiency with a 60-87 V MPPT window and 87 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 555 W

- **AC Voltage** : 208 V, commercial single-phase

- **Min PV Breaker** : 15 A (14 AWG Cu)

- **CEC Efficiency** : 97.1%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Enphase Energy Inc: IQ8D-BAT-DOM {208V} Compare Against Peer CEC Listings?

CEC efficiency rank (#887), 60-87 V MPPT tracking, and panel fit for Enphase Energy Inc: IQ8D-BAT-DOM {208V}. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Operating at 208 V, commercial single-phase, Enphase Energy Inc: IQ8D-BAT-DOM {208V} converts DC array energy at 97.1% CEC weighted efficiency (top 38.2%; higher than 61.8% of peers) with a 87 V max DC input and 7.77521 A max input current for NEC 690.7 string safety. Compare this 555 W grid-tied PV inverter directly with Cherry Solution Co Ltd: CMI-600S-SA {208V} (608 W). Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit.

## Where Does Enphase Energy Inc: IQ8D-BAT-DOM {208V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting Enphase Energy Inc: IQ8D-BAT-DOM {208V} at 555 W continuous AC output. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

## What Dataset Percentiles Define Enphase Energy Inc: IQ8D-BAT-DOM {208V}?

Dataset percentiles comparing Enphase Energy Inc: IQ8D-BAT-DOM {208V} against 2,343 certified grid-support inverters nationwide. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

## What Do the Dataset Ranks Show for Enphase Energy Inc: IQ8D-BAT-DOM {208V}?

Engineering highlights for Enphase Energy Inc: IQ8D-BAT-DOM {208V} covering efficiency, 14 AWG Cu feeder, and panel compatibility. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Eff #887 / 2,343

### 97.1% CEC Weighted Efficiency

+0.69 pts vs the 96.41% 208 V median; overall power rank #1,939 (555 W, below CEC median; higher than 17.2% of peers).

NEC 705.12 Check

### 15 A Required Backfeed OCPD

125% x 2.7 A = 3.4 A -> 15 A standard OCPD using 14 AWG Cu (75 C).

MPPT Window

### 60 V - 87 V (Max 87 V DC)

Tracking span of 27.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

### PASS (120% Commercial Busbar)

Evaluated for 208 V, commercial single-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 554.9W / 208 V -> 2.7 A | Breaker >= 1.25 * 2.7 = 3.4 A -> 15 A

CEC Inverters.csv for Enphase Energy Inc: IQ8D-BAT-DOM {208V}: Paco=554.9 W, Vac=208 V, Vdcmax=87.0 V, Eff=97.1%.

**Result:** Min 15 A breaker & 14 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).

## What Are the Published CEC Specifications for Enphase Energy Inc: IQ8D-BAT-DOM {208V}?

California Energy Commission Solar Equipment List parameters for Enphase Energy Inc: IQ8D-BAT-DOM {208V} (grid-tied PV inverter) interconnection. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Official California Energy Commission (NREL SAM) test parameters for Enphase Energy Inc: IQ8D-BAT-DOM {208V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 555 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 208 V, commercial single-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 87 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 60 V - 87 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 7.77521 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 97.1% | Calculated AC/DC conversion ratio from CEC test protocol |
| **Inverter Topology** | Hybrid: No (Grid-Tied PV) | CEC Solar Equipment List grid-support certification |

## What Switchgear Limits Apply to Enphase Energy Inc: IQ8D-BAT-DOM {208V} (208 V, commercial single-phase)?

Panelboard and switchgear backfeed allowances for Enphase Energy Inc: IQ8D-BAT-DOM {208V} (15 A OCPD). Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Evaluates Enphase Energy Inc: IQ8D-BAT-DOM {208V} (15 A required OCPD at 208 V, commercial single-phase) across standard distribution busbars.

| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **200A Bus / 200A Main (208V)** | 40 A | 15 A | PASS (120% Commercial Busbar) |
| **400A Bus / 400A Main (208V)** | 80 A | 15 A | PASS (120% Commercial Busbar) |
| **600A Bus / 600A Main (208V)** | 120 A | 15 A | PASS (120% Commercial Busbar) |
| **800A Bus / 800A Main (208V)** | 160 A | 15 A | PASS (120% Commercial Busbar) |
| **1,200A Bus / 1,200A Main (208V)** | 240 A | 15 A | PASS (120% Commercial Busbar) |

## Which CEC PV Module Strings Pair With Enphase Energy Inc: IQ8D-BAT-DOM {208V}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for Enphase Energy Inc: IQ8D-BAT-DOM {208V}. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Sampled CEC PV modules aligned within 60.0-87.0 V MPPT and 87.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 1 panel (micro/module) | 0.59 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 2 panels (fixed) | 0.88 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 1 panel (micro/module) | 0.42 kW |
| [**Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-515**](https://epri-peac.com/solar-equipment/modules/chint-new-energy-technology-co-ltd/chint-new-energy-technology-co-ltd-chsm72m-dg-f-bh-515/) | 515.0 W | 53.76 V | 1 panel (micro/module) | 0.52 kW |

## Which Competing Grid-Support Inverters Compare to Enphase Energy Inc: IQ8D-BAT-DOM {208V}?

Four alternative CEC inverters matched to Enphase Energy Inc: IQ8D-BAT-DOM {208V} (555 W AC), led by Cherry Solution Co Ltd: CMI-600S-SA {208V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Cherry Solution Co Ltd: CMI-600S-SA {208V}**](https://epri-peac.com/solar-equipment/inverters/cherry-solution-co-ltd/cherry-solution-co-ltd-cmi-600s-sa-208v/) Cherry Solution Co Ltd | 608 W | +53 W | 208.0 V | 50.0 V | 96.49% |
| [**Cherry Solution Co Ltd: CMI-600S-WA {208V}**](https://epri-peac.com/solar-equipment/inverters/cherry-solution-co-ltd/cherry-solution-co-ltd-cmi-600s-wa-208v/) Cherry Solution Co Ltd | 608 W | +53 W | 208.0 V | 50.0 V | 96.49% |
| [**Aptos Solar Technology LLC: MAC-400 {208V}**](https://epri-peac.com/solar-equipment/inverters/aptos-solar-technology-llc/aptos-solar-technology-llc-mac-400-208v/) Aptos Solar Technology LLC | 387 W | -168 W | 208.0 V | 48.0 V | 96.11% |
| [**Aptos Solar Technology LLC: MAC-400R {208V}**](https://epri-peac.com/solar-equipment/inverters/aptos-solar-technology-llc/aptos-solar-technology-llc-mac-400r-208v/) Aptos Solar Technology LLC | 387 W | -168 W | 208.0 V | 48.0 V | 96.11% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Enphase Energy Inc: IQ8D-BAT-DOM {208V}?

Check Enphase Energy Inc: IQ8D-BAT-DOM {208V} (555 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 87 V DC on Enphase Energy Inc: IQ8D-BAT-DOM {208V}.

### Enphase Energy Inc: IQ8D-BAT-DOM {208V} Panel & Wire Spec

Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (2.7 A continuous).

### Alternative Inverter Comparison

Compare efficiency (97.1%) and MPPT window (60-87 V) directly against Cherry Solution Co Ltd: CMI-600S-SA {208V} (608 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Enphase Energy Inc: IQ8D-BAT-DOM {208V} by Enphase Energy Inc covering breaker sizing, MPPT limits, and 208 V, commercial single-phase interconnection.

### What breaker and wire size does Enphase Energy Inc: IQ8D-BAT-DOM {208V} require?

At 555 W continuous AC (208 V, commercial single-phase), continuous current is 2.7 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.

### What commercial switchgear or feeder sizing does Enphase Energy Inc: IQ8D-BAT-DOM {208V} require?

At 555 W AC and 208 V, commercial single-phase, continuous line current is 2.7 A, requiring a 15 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.

### How does Enphase Energy Inc: IQ8D-BAT-DOM {208V} compare to Cherry Solution Co Ltd: CMI-600S-SA {208V}?

Enphase Energy Inc: IQ8D-BAT-DOM {208V} delivers 555 W AC at 97.1% CEC efficiency with a 87 V DC ceiling, while Cherry Solution Co Ltd: CMI-600S-SA {208V} outputs 608 W at 208 V, commercial single-phase.

## Related Pages

Explore Enphase Energy Inc hardware, Cherry Solution Co Ltd: CMI-600S-SA {208V}, utility rates, and NEC 705.12 sizing calculators alongside Enphase Energy Inc: IQ8D-BAT-DOM {208V}.

[All Enphase Energy Inc Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/enphase-energy-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Enphase Energy Inc

- [All Enphase Energy Inc Specs](https://epri-peac.com/solar-equipment/brands/enphase-energy-inc/)
- [Enphase Energy Inc: IQBATTERY-10C-1P-NA {240V}](https://epri-peac.com/solar-equipment/inverters/enphase-energy-inc/enphase-energy-inc-iqbattery-10c-1p-na-240v/)
- [Enphase Energy Inc: IQBATTERY-10CS-1P-NA {240V}](https://epri-peac.com/solar-equipment/inverters/enphase-energy-inc/enphase-energy-inc-iqbattery-10cs-1p-na-240v/)
- [Enphase Energy Inc: IQ8D-72-E-US {208V}](https://epri-peac.com/solar-equipment/inverters/enphase-energy-inc/enphase-energy-inc-iq8d-72-e-us-208v/)
- [Enphase Energy Inc: IQ8D-BAT-240 {240V}](https://epri-peac.com/solar-equipment/inverters/enphase-energy-inc/enphase-energy-inc-iq8d-bat-240-240v/)
- [Enphase Energy Inc: IQ8D-BAT {240V}](https://epri-peac.com/solar-equipment/inverters/enphase-energy-inc/enphase-energy-inc-iq8d-bat-240v/)