---
title: "EcoFlow Inc: EF-PCS-24 {240V Inverter (11,444W)"
url: https://epri-peac.com/solar-equipment/inverters/ecoflow-inc/ecoflow-inc-ef-pcs-24-240v-115kw/
description: "CEC specs for EcoFlow Inc: EF-PCS-24 {240V 115kW}: 11,444W AC, 240V, 60A OCPD, and NEC 705.12 checks. Verified US government and CEC engineering data."
---

CEC Grid-Support Inverter

# EcoFlow Inc: EF-PCS-24 {240V 115kW} — CEC Inverter Specifications

Manufacturer: [**EcoFlow Inc**](https://epri-peac.com/solar-equipment/brands/ecoflow-inc/) Registry: **CEC Verified Engineering Specification**

EcoFlow Inc: EF-PCS-24 {240V 115kW} outputs 11,444 W AC at 240 V (47.7 A continuous, 60 A OCPD), ranking #1,467 of 2,343 CEC inverters at 96.56% efficiency with a 120-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 11,444 W

- **AC Voltage** : 240 V

- **Min PV Breaker** : 60 A (6 AWG Cu)

- **CEC Efficiency** : 96.56%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does EcoFlow Inc: EF-PCS-24 {240V 115kW} Compare Against Peer CEC Listings?

CEC efficiency rank (#1,467), 120-480 V MPPT tracking, and panel fit for EcoFlow Inc: EF-PCS-24 {240V 115kW}. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Operating at 240 V, EcoFlow Inc: EF-PCS-24 {240V 115kW} converts DC array energy at 96.56% CEC weighted efficiency (below overall CEC median; higher than 36.1% of peers) with a 480 V max DC input and 32.033 A max input current for NEC 690.7 string safety. Compare this 11,444 W hybrid battery-capable inverter directly with Altenergy Power System Inc: ELS-114 {240V} (11,415 W). Its 60 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.

## Where Does EcoFlow Inc: EF-PCS-24 {240V 115kW} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting EcoFlow Inc: EF-PCS-24 {240V 115kW} at 11,444 W continuous AC output. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

## What Dataset Percentiles Define EcoFlow Inc: EF-PCS-24 {240V 115kW}?

Dataset percentiles comparing EcoFlow Inc: EF-PCS-24 {240V 115kW} against 2,343 certified grid-support inverters nationwide. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

## What Do the Dataset Ranks Show for EcoFlow Inc: EF-PCS-24 {240V 115kW}?

Engineering highlights for EcoFlow Inc: EF-PCS-24 {240V 115kW} covering efficiency, 6 AWG Cu feeder, and panel compatibility. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Eff #1,467 / 2,343

### 96.56% CEC Weighted Efficiency

-0.12 pts vs the 96.68% 240 V median; overall power rank #772 (11,444 W, top 32.9%; higher than 67.1% of peers).

NEC 705.12 Check

### 60 A Required Backfeed OCPD

125% x 47.7 A = 59.6 A -> 60 A standard OCPD using 6 AWG Cu (75 C).

MPPT Window

### 120 V - 480 V (Max 480 V DC)

Tracking span of 360.0 V; listed since 2026-06-01 (hybrid battery-capable inverter).

Panel Fit (240V)

### Needs Derate / Tap 705.11

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 11444.2W / 240 V -> 47.7 A | Breaker >= 1.25 * 47.7 = 59.6 A -> 60 A

CEC Inverters.csv for EcoFlow Inc: EF-PCS-24 {240V 115kW}: Paco=11444.2 W, Vac=240 V, Vdcmax=480.0 V, Eff=96.56%.

**Result:** Min 60 A breaker & 6 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.

## What Are the Published CEC Specifications for EcoFlow Inc: EF-PCS-24 {240V 115kW}?

California Energy Commission Solar Equipment List parameters for EcoFlow Inc: EF-PCS-24 {240V 115kW} (hybrid battery-capable inverter) interconnection. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Official California Energy Commission (NREL SAM) test parameters for EcoFlow Inc: EF-PCS-24 {240V 115kW}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 11,444 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 480 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 120 V - 480 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 32.033 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 96.56% | Calculated AC/DC conversion ratio from CEC test protocol |
| **CEC Listing Date & Hybrid** | 2026-06-01 / Hybrid: Yes (Battery Capable) | Utility interconnection approval metadata |

## Can a Residential Panel Meet 120% Busbar Limits for EcoFlow Inc: EF-PCS-24 {240V 115kW}?

Panelboard and switchgear backfeed allowances for EcoFlow Inc: EF-PCS-24 {240V 115kW} (60 A OCPD). Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Evaluates EcoFlow Inc: EF-PCS-24 {240V 115kW} (60 A required OCPD at 240 V) across standard distribution busbars.

| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **100A Bus / 100A Main** | 20 A | 60 A | Needs Derate / Tap 705.11 |
| **150A Bus / 150A Main** | 30 A | 60 A | Needs Derate / Tap 705.11 |
| **200A Bus / 200A Main** | 40 A | 60 A | Needs Derate / Tap 705.11 |
| **200A Bus / 175A Main** | 65 A | 60 A | PASS (120% Rule) |
| **225A Bus / 200A Main** | 70 A | 60 A | PASS (120% Rule) |

## Which CEC PV Module Strings Pair With EcoFlow Inc: EF-PCS-24 {240V 115kW}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for EcoFlow Inc: EF-PCS-24 {240V 115kW}. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Sampled CEC PV modules aligned within 120.0-480.0 V MPPT and 480.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 3 to 8 panels | 4.72 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 4 to 11 panels | 4.84 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 4 to 10 panels | 4.25 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 5 to 11 panels | 2.2 kW |

## Which Competing Grid-Support Inverters Compare to EcoFlow Inc: EF-PCS-24 {240V 115kW}?

Four alternative CEC inverters matched to EcoFlow Inc: EF-PCS-24 {240V 115kW} (11,444 W AC), led by Altenergy Power System Inc: ELS-114 {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Altenergy Power System Inc: ELS-114 {240V}**](https://epri-peac.com/solar-equipment/inverters/altenergy-power-system-inc/altenergy-power-system-inc-els-114-240v/) Altenergy Power System Inc | 11,415 W | -29 W | 240.0 V | 60.0 V | 93.08% |
| [**Dyness Digital Energy Technology Co LTD: TX114K-HM {240V}**](https://epri-peac.com/solar-equipment/inverters/dyness-digital-energy-technology-co-ltd/dyness-digital-energy-technology-co-ltd-tx114k-hm-240v/) Dyness Digital Energy Technology Co LTD | 11,498 W | +54 W | 240.0 V | 500.0 V | 96.41% |
| [**Dyness Digital Energy Technology Co LTD: TX114K-AM {240V}**](https://epri-peac.com/solar-equipment/inverters/dyness-digital-energy-technology-co-ltd/dyness-digital-energy-technology-co-ltd-tx114k-am-240v/) Dyness Digital Energy Technology Co LTD | 11,519 W | +75 W | 240.0 V | 490.0 V | 96.21% |
| [**Base Power Inc: MIN 11400TL-XH-US {240V}**](https://epri-peac.com/solar-equipment/inverters/base-power-inc/base-power-inc-min-11400tl-xh-us-240v/) Base Power Inc | 11,520 W | +76 W | 240.0 V | 480.0 V | 97.76% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for EcoFlow Inc: EF-PCS-24 {240V 115kW}?

Check EcoFlow Inc: EF-PCS-24 {240V 115kW} (11,444 W AC, 60 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Its 60 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on EcoFlow Inc: EF-PCS-24 {240V 115kW}.

### EcoFlow Inc: EF-PCS-24 {240V 115kW} Panel & Wire Spec

Size 75 C copper conductors at 6 AWG Cu on a 60 A OCPD breaker (47.7 A continuous).

### Alternative Inverter Comparison

Compare efficiency (96.56%) and MPPT window (120-480 V) directly against Altenergy Power System Inc: ELS-114 {240V} (11,415 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for EcoFlow Inc: EF-PCS-24 {240V 115kW} by EcoFlow Inc covering breaker sizing, MPPT limits, and 240 V interconnection.

### What breaker and wire size does EcoFlow Inc: EF-PCS-24 {240V 115kW} require?

At 11,444 W continuous AC (240 V), continuous current is 47.7 A; 125% NEC 690.8/705.12 sizing requires a 60 A breaker and 6 AWG Cu (75 C) wire.

### Does EcoFlow Inc: EF-PCS-24 {240V 115kW} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 60 A at 240 V means Needs Derate / Tap 705.11.

### How does EcoFlow Inc: EF-PCS-24 {240V 115kW} compare to Altenergy Power System Inc: ELS-114 {240V}?

EcoFlow Inc: EF-PCS-24 {240V 115kW} delivers 11,444 W AC at 96.56% CEC efficiency with a 480 V DC ceiling, while Altenergy Power System Inc: ELS-114 {240V} outputs 11,415 W at 240 V.

## Related Pages

Explore EcoFlow Inc hardware, Altenergy Power System Inc: ELS-114 {240V}, utility rates, and NEC 705.12 sizing calculators alongside EcoFlow Inc: EF-PCS-24 {240V 115kW}.

[All EcoFlow Inc Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/ecoflow-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From EcoFlow Inc

- [All EcoFlow Inc Specs](https://epri-peac.com/solar-equipment/brands/ecoflow-inc/)
- [EcoFlow Inc: EF-PCS-24 {208V 24kW}](https://epri-peac.com/solar-equipment/inverters/ecoflow-inc/ecoflow-inc-ef-pcs-24-208v-24kw/)
- [EcoFlow Inc: EF-PCS-24 {240V 24kW}](https://epri-peac.com/solar-equipment/inverters/ecoflow-inc/ecoflow-inc-ef-pcs-24-240v-24kw/)
- [EcoFlow Inc: EF-PCS-24 {208V 115kW}](https://epri-peac.com/solar-equipment/inverters/ecoflow-inc/ecoflow-inc-ef-pcs-24-208v-115kw/)
