title: "EcoFlow Inc: EF-PCS-24 {208V 24kW} Inverter (24,291W)"
url: https://epri-peac.com/solar-equipment/inverters/ecoflow-inc/ecoflow-inc-ef-pcs-24-208v-24kw/
description: "CEC specs for EcoFlow Inc: EF-PCS-24 {208V 24kW}: 24,291W AC, 208V, 90A OCPD, and NEC 705.12 checks. Verified US government and CEC engineering data."
---

CEC Grid-Support Inverter

# EcoFlow Inc: EF-PCS-24 {208V 24kW} — CEC Inverter Specifications

Manufacturer: [**EcoFlow Inc**](https://epri-peac.com/solar-equipment/brands/ecoflow-inc/) Registry: **CEC Verified Engineering Specification**

EcoFlow Inc: EF-PCS-24 {208V 24kW} outputs 24,291 W AC at 208 V, 3-phase (67.4 A continuous, 90 A OCPD), ranking #1,953 of 2,343 CEC inverters at 96.01% efficiency with a 320-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 24,291 W

- **AC Voltage** : 208 V, 3-phase

- **Min PV Breaker** : 90 A (3 AWG Cu)

- **CEC Efficiency** : 96.01%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does EcoFlow Inc: EF-PCS-24 {208V 24kW} Compare Against Peer CEC Listings?

Breaker sizing (90 A), 3 AWG Cu wire rules, and DC input limits for EcoFlow Inc: EF-PCS-24 {208V 24kW}.

Classified as a hybrid battery-capable inverter (listed since 2026-06-01), EcoFlow Inc: EF-PCS-24 {208V 24kW} requires 84.2 A design capacity -> 90 A breaker using 3 AWG Cu copper at 75 C terminals. Weighted efficiency sits at 96.01% (-0.81 pts vs overall CEC median) across 2,343 CEC models, while commercial 208 v, 3-phase switchgear interconnection uses 1,200a bus / 1,200a main (208v) or nec 705.11 supply-side tap.

## Where Does EcoFlow Inc: EF-PCS-24 {208V 24kW} Fall Across Listed CEC Models?

Output power comparison showing where EcoFlow Inc: EF-PCS-24 {208V 24kW} sits among all 2,343 CEC-listed grid-support inverters. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

## What Dataset Percentiles Define EcoFlow Inc: EF-PCS-24 {208V 24kW}?

Relative ranking of EcoFlow Inc: EF-PCS-24 {208V 24kW} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

## What Do the Dataset Ranks Show for EcoFlow Inc: EF-PCS-24 {208V 24kW}?

Snapshot of EcoFlow Inc: EF-PCS-24 {208V 24kW} efficiency rank (#1,953), OCPD breaker size, MPPT span, and busbar verdict.

Eff #1,953 / 2,343

### 96.01% CEC Weighted Efficiency

-0.40 pts vs the 96.41% 208 V median; overall power rank #612 (24,291 W, top 26.1%; higher than 73.9% of peers).

NEC 705.12 Check

### 90 A Required Backfeed OCPD

125% x 67.4 A = 84.2 A -> 90 A standard OCPD using 3 AWG Cu (75 C).

MPPT Window

### 320 V - 480 V (Max 480 V DC)

Tracking span of 160.0 V; listed since 2026-06-01 (hybrid battery-capable inverter).

Commercial / 3-Phase Fit

### Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 208 V, 3-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 24291.4W / 208 V 3-phase -> 67.4 A | Breaker >= 1.25 * 67.4 = 84.2 A -> 90 A

CEC Inverters.csv for EcoFlow Inc: EF-PCS-24 {208V 24kW}: Paco=24291.4 W, Vac=208 V, Vdcmax=480.0 V, Eff=96.01%.

**Result:** Min 90 A breaker & 3 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).

## What Are the Published CEC Specifications for EcoFlow Inc: EF-PCS-24 {208V 24kW}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for EcoFlow Inc: EF-PCS-24 {208V 24kW}. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Official California Energy Commission (NREL SAM) test parameters for EcoFlow Inc: EF-PCS-24 {208V 24kW}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 24,291 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 208 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 480 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 320 V - 480 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 63.2516 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 96.01% | Calculated AC/DC conversion ratio from CEC test protocol |
| **CEC Listing Date & Hybrid** | 2026-06-01 / Hybrid: Yes (Battery Capable) | Utility interconnection approval metadata |

## What Switchgear Limits Apply to EcoFlow Inc: EF-PCS-24 {208V 24kW} (208 V, 3-phase)?

NEC 705.12(B)(3)(2) backfeed compliance table for EcoFlow Inc: EF-PCS-24 {208V 24kW} at 208 V, 3-phase.

Evaluates EcoFlow Inc: EF-PCS-24 {208V 24kW} (90 A required OCPD at 208 V, 3-phase) across standard distribution busbars.

| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **200A Bus / 200A Main (208V)** | 40 A | 90 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **400A Bus / 400A Main (208V)** | 80 A | 90 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **600A Bus / 600A Main (208V)** | 120 A | 90 A | PASS (120% Commercial Busbar) |
| **800A Bus / 800A Main (208V)** | 160 A | 90 A | PASS (120% Commercial Busbar) |
| **1,200A Bus / 1,200A Main (208V)** | 240 A | 90 A | PASS (120% Commercial Busbar) |

## Which CEC PV Module Strings Pair With EcoFlow Inc: EF-PCS-24 {208V 24kW}?

Minimum and maximum series solar module strings fitting EcoFlow Inc: EF-PCS-24 {208V 24kW} MPPT and 480 V limits.

Sampled CEC PV modules aligned within 320.0-480.0 V MPPT and 480.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 8 panels (fixed) | 4.72 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 10 to 11 panels | 4.84 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 10 panels (fixed) | 4.25 kW |
| [**Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-515**](https://epri-peac.com/solar-equipment/modules/chint-new-energy-technology-co-ltd/chint-new-energy-technology-co-ltd-chsm72m-dg-f-bh-515/) | 515.0 W | 53.76 V | 8 panels (fixed) | 4.12 kW |

## Which Competing Grid-Support Inverters Compare to EcoFlow Inc: EF-PCS-24 {208V 24kW}?

Peer 208 V, 3-phase CEC inverters near 24,291 W AC output such as Chint Power Systems America: CPS SCA25KTL-DO/US-208 {208V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Chint Power Systems America: CPS SCA25KTL-DO/US-208 {208V}**](https://epri-peac.com/solar-equipment/inverters/chint-power-systems-america/chint-power-systems-america-cps-sca25ktl-do-us-208-208v/) Chint Power Systems America | 25,000 W | +709 W | 208.0 V | 850.0 V | 96.26% |
| [**CSI Solar Co Ltd: CSI-30K-T208GL03-U {208V}**](https://epri-peac.com/solar-equipment/inverters/csi-solar-co-ltd/csi-solar-co-ltd-csi-30k-t208gl03-u-208v/) CSI Solar Co Ltd | 29,878 W | +5587 W | 208.0 V | 680.0 V | 96.38% |
| [**EG4 Electronics LLC: IV-16000-HYB-AW-FX-xx {208V}**](https://epri-peac.com/solar-equipment/inverters/eg4-electronics-llc/eg4-electronics-llc-iv-16000-hyb-aw-fx-xx-208v/) EG4 Electronics LLC | 13,899 W | -10393 W | 208.0 V | 440.0 V | 96.46% |
| [**Chint Power Systems America: CPS ECH12KTL/US {208V}**](https://epri-peac.com/solar-equipment/inverters/chint-power-systems-america/chint-power-systems-america-cps-ech12ktl-us-208v/) Chint Power Systems America | 12,000 W | -12291 W | 208.0 V | 480.0 V | 96.63% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for EcoFlow Inc: EF-PCS-24 {208V 24kW}?

Check EcoFlow Inc: EF-PCS-24 {208V 24kW} (24,291 W AC, 90 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 208 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on EcoFlow Inc: EF-PCS-24 {208V 24kW}.

### EcoFlow Inc: EF-PCS-24 {208V 24kW} Panel & Wire Spec

Size 75 C copper conductors at 3 AWG Cu on a 90 A OCPD breaker (67.4 A continuous).

### Alternative Inverter Comparison

Compare efficiency (96.01%) and MPPT window (320-480 V) directly against Chint Power Systems America: CPS SCA25KTL-DO/US-208 {208V} (25,000 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for EcoFlow Inc: EF-PCS-24 {208V 24kW} by EcoFlow Inc covering breaker sizing, MPPT limits, and 208 V, 3-phase interconnection.

### What breaker and wire size does EcoFlow Inc: EF-PCS-24 {208V 24kW} require?

At 24,291 W continuous AC (208 V, 3-phase), continuous current is 67.4 A; 125% NEC 690.8/705.12 sizing requires a 90 A breaker and 3 AWG Cu (75 C) wire.

### What commercial switchgear or feeder sizing does EcoFlow Inc: EF-PCS-24 {208V 24kW} require?

At 24,291 W AC and 208 V, 3-phase, continuous line current is 67.4 A, requiring a 90 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.

### How does EcoFlow Inc: EF-PCS-24 {208V 24kW} compare to Chint Power Systems America: CPS SCA25KTL-DO/US-208 {208V}?

EcoFlow Inc: EF-PCS-24 {208V 24kW} delivers 24,291 W AC at 96.01% CEC efficiency with a 480 V DC ceiling, while Chint Power Systems America: CPS SCA25KTL-DO/US-208 {208V} outputs 25,000 W at 208 V, 3-phase.

## Related Pages

Explore EcoFlow Inc hardware, Chint Power Systems America: CPS SCA25KTL-DO/US-208 {208V}, utility rates, and NEC 705.12 sizing calculators alongside EcoFlow Inc: EF-PCS-24 {208V 24kW}.

[All EcoFlow Inc Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/ecoflow-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From EcoFlow Inc

- [All EcoFlow Inc Specs](https://epri-peac.com/solar-equipment/brands/ecoflow-inc/)
- [EcoFlow Inc: EF-PCS-24 {240V 24kW}](https://epri-peac.com/solar-equipment/inverters/ecoflow-inc/ecoflow-inc-ef-pcs-24-240v-24kw/)
- [EcoFlow Inc: EF-PCS-24 {240V 115kW}](https://epri-peac.com/solar-equipment/inverters/ecoflow-inc/ecoflow-inc-ef-pcs-24-240v-115kw/)
- [EcoFlow Inc: EF-PCS-24 {208V 115kW}](https://epri-peac.com/solar-equipment/inverters/ecoflow-inc/ecoflow-inc-ef-pcs-24-208v-115kw/)