title: "DYNAPOWER COMPANY LLC: CPS-2500 Inverter (1,353,700W)"
url: https://epri-peac.com/solar-equipment/inverters/dynapower-company-llc/dynapower-company-llc-cps-2500-gen5-415v/
description: "CEC specs for DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {415V}: 1,353,700W AC, 415V, 2400A OCPD, and NEC 705.12 checks. Source-verified US engineering data."
---

CEC Grid-Support Inverter

# DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {415V} — CEC Inverter Specifications

Manufacturer: [**DYNAPOWER COMPANY LLC**](https://epri-peac.com/solar-equipment/brands/dynapower-company-llc/) Registry: **CEC Verified Engineering Specification**

DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {415V} outputs 1,353,700 W AC at 415 V, 3-phase (1883.3 A continuous, 2,400 A OCPD), ranking #1,120 of 2,343 CEC inverters at 96.9% efficiency with a 730-1,400 V MPPT window and 1,400 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 1,353,700 W

- **AC Voltage** : 415 V, 3-phase

- **Min PV Breaker** : 2,400 A (parallel Cu feeders)

- **CEC Efficiency** : 96.9%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {415V} Compare Against Peer CEC Listings?

How DYNAPOWER COMPANY LLC DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {415V} compares on 96.9% efficiency, MPPT span, and 120% busbar interconnection.

With a 730-1,400 V MPPT tracking band and 1,400 V DC ceiling, DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {415V} handles 1,353,700 W continuous AC (331,226 W above the 1,022,474 W 415 V median). Commercial 415 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (415V) or NEC 705.11 supply-side tap. Installers comparing DYNAPOWER COMPANY LLC against Schneider Electric USA Inc: CS1666-3-NA {575V} (1,666,000 W) should verify whether active in CEC directory grid-support firmware meets local IEEE 1547 utility rules.

## Where Does DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {415V} Fall Across Listed CEC Models?

Position of DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {415V} (1,353,700 W AC) relative to the 7,680 W CEC median inverter.

## What Dataset Percentiles Define DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {415V}?

Percentile placement of DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {415V} across AC power class, conversion efficiency, and backfeed breaker size.

## What Do the Dataset Ranks Show for DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {415V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {415V}.

Eff #1,120 / 2,343

### 96.9% CEC Weighted Efficiency

-0.40 pts vs the 97.3% 415 V median; overall power rank #140 (1,353,700 W, top 6.0%; higher than 94.0% of peers).

NEC 705.12 Check

### 2,400 A Required Backfeed OCPD

125% x 1883.3 A = 2354.1 A -> 2,400 A standard OCPD using parallel Cu feeders (75 C).

MPPT Window

### 730 V - 1,400 V (Max 1,400 V DC)

Tracking span of 670.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

### Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 415 V, 3-phase switchgear (200A Bus / 200A Main (415V) to 1,200A Bus / 1,200A Main (415V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 1353700.0W / 415 V 3-phase -> 1883.3 A | Breaker >= 1.25 * 1883.3 = 2354.1 A -> 2,400 A

CEC Inverters.csv for DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {415V}: Paco=1353700.0 W, Vac=415 V, Vdcmax=1400.0 V, Eff=96.9%.

**Result:** Min 2,400 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (415V): Supply-Side Tap (705.11) / Dedicated Switchboard.

## What Are the Published CEC Specifications for DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {415V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {415V}.

Official California Energy Commission (NREL SAM) test parameters for DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {415V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 1,353,700 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 415 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 1,400 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 730 V - 1,400 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 1270.06 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 96.9% | Calculated AC/DC conversion ratio from CEC test protocol |
| **Inverter Topology** | Hybrid: No (Grid-Tied PV) | CEC Solar Equipment List grid-support certification |

## What Switchgear Limits Apply to DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {415V} (415 V, 3-phase)?

Check whether DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {415V} (2,400 A breaker) fits without main breaker derate or supply-side taps.

Evaluates DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {415V} (2400 A required OCPD at 415 V, 3-phase) across standard distribution busbars.

| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **200A Bus / 200A Main (415V)** | 40 A | 2,400 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **400A Bus / 400A Main (415V)** | 80 A | 2,400 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **600A Bus / 600A Main (415V)** | 120 A | 2,400 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **800A Bus / 800A Main (415V)** | 160 A | 2,400 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **1,200A Bus / 1,200A Main (415V)** | 240 A | 2,400 A | Supply-Side Tap (705.11) / Dedicated Switchboard |

## Which CEC PV Module Strings Pair With DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {415V}?

Verified cold-weather (-10 C) series module counts matched to DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {415V}'s 1,400 V DC ceiling.

Sampled CEC PV modules aligned within 730.0-1400.0 V MPPT and 1400.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 18 to 24 panels | 14.16 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 22 to 33 panels | 14.52 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 22 to 31 panels | 13.18 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 26 to 34 panels | 6.8 kW |

## Which Competing Grid-Support Inverters Compare to DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {415V}?

Alternative CEC inverters comparable to DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {415V}, including Schneider Electric USA Inc: CS1666-3-NA {575V} (1,666,000 W) at 415 V, 3-phase.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Schneider Electric USA Inc: CS1666-3-NA {575V}**](https://epri-peac.com/solar-equipment/inverters/schneider-electric-usa-inc/schneider-electric-usa-inc-cs1666-3-na-575v/) Schneider Electric USA Inc | 1,666,000 W | +312300 W | 575.0 V | 1200.0 V | 97.54% |
| [**SINENG ELECTRIC CO LTD: EH-1725-HA-UD-US {690V}**](https://epri-peac.com/solar-equipment/inverters/sineng-electric-co-ltd/sineng-electric-co-ltd-eh-1725-ha-ud-us-690v/) SINENG ELECTRIC CO LTD | 1,726,700 W | +373000 W | 690.0 V | 1500.0 V | 98.32% |
| [**EPC Power Corp: 50-200100 {720V}**](https://epri-peac.com/solar-equipment/inverters/epc-power-corp/epc-power-corp-50-200100-720v/) EPC Power Corp | 561,806 W | -791894 W | 720.0 V | 1500.0 V | 98.58% |
| [**Power Electronics: FS2250CU15O3 {600V}**](https://epri-peac.com/solar-equipment/inverters/power-electronics/power-electronics-fs2250cu15o3-600v/) Power Electronics | 2,420,370 W | +1066670 W | 600.0 V | 1200.0 V | 97.82% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {415V}?

Check DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {415V} (1,353,700 W AC, 2,400 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 415 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (415V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,400 V DC on DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {415V}.

### DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {415V} Panel & Wire Spec

Size 75 C copper conductors at parallel Cu feeders on a 2,400 A OCPD breaker (1883.3 A continuous).

### Alternative Inverter Comparison

Compare efficiency (96.9%) and MPPT window (730-1,400 V) directly against Schneider Electric USA Inc: CS1666-3-NA {575V} (1,666,000 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {415V} by DYNAPOWER COMPANY LLC covering breaker sizing, MPPT limits, and 415 V, 3-phase interconnection.

### What breaker and wire size does DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {415V} require?

At 1,353,700 W continuous AC (415 V, 3-phase), continuous current is 1883.3 A; 125% NEC 690.8/705.12 sizing requires a 2,400 A breaker and parallel Cu feeders (75 C) wire.

### What commercial switchgear or feeder sizing does DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {415V} require?

At 1,353,700 W AC and 415 V, 3-phase, continuous line current is 1883.3 A, requiring a 2,400 A OCPD and 1,200A Bus / 1,200A Main (415V) or NEC 705.11 interconnection.

### How does DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {415V} compare to Schneider Electric USA Inc: CS1666-3-NA {575V}?

DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {415V} delivers 1,353,700 W AC at 96.9% CEC efficiency with a 1,400 V DC ceiling, while Schneider Electric USA Inc: CS1666-3-NA {575V} outputs 1,666,000 W at 415 V, 3-phase.

## Related Pages

Explore DYNAPOWER COMPANY LLC hardware, Schneider Electric USA Inc: CS1666-3-NA {575V}, utility rates, and NEC 705.12 sizing calculators alongside DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {415V}.

[All DYNAPOWER COMPANY LLC Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/dynapower-company-llc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From DYNAPOWER COMPANY LLC

- [All DYNAPOWER COMPANY LLC Specs](https://epri-peac.com/solar-equipment/brands/dynapower-company-llc/)
- [DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {690V}](https://epri-peac.com/solar-equipment/inverters/dynapower-company-llc/dynapower-company-llc-cps-2500-gen5-690v/)
- [DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {600V}](https://epri-peac.com/solar-equipment/inverters/dynapower-company-llc/dynapower-company-llc-cps-1500-gen4-600v/)
- [DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V}](https://epri-peac.com/solar-equipment/inverters/dynapower-company-llc/dynapower-company-llc-cps-1250-gen5-800v/)
- [DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V}](https://epri-peac.com/solar-equipment/inverters/dynapower-company-llc/dynapower-company-llc-cps-1500-gen4-480v/)
- [DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {690V}](https://epri-peac.com/solar-equipment/inverters/dynapower-company-llc/dynapower-company-llc-cps-1250-gen5-690v/)