title: "DYNAPOWER COMPANY LLC: CPS-1250 Inverter (1,146,100W)"
url: https://epri-peac.com/solar-equipment/inverters/dynapower-company-llc/dynapower-company-llc-cps-1250-gen5-690v/
description: "CEC specs for DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {690V}: 1,146,100W AC, 690V, 1200A OCPD, and NEC 705.12 checks. Source-verified US engineering data."
---

CEC Grid-Support Inverter

# DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {690V} — CEC Inverter Specifications

Manufacturer: [**DYNAPOWER COMPANY LLC**](https://epri-peac.com/solar-equipment/brands/dynapower-company-llc/) Registry: **CEC Verified Engineering Specification**

DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {690V} outputs 1,146,100 W AC at 690 V, 3-phase (959.0 A continuous, 1,200 A OCPD), ranking #48 of 2,343 CEC inverters at 98.61% efficiency with a 1,020-1,500 V MPPT window and 1,500 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 1,146,100 W

- **AC Voltage** : 690 V, 3-phase

- **Min PV Breaker** : 1,200 A (parallel Cu feeders)

- **CEC Efficiency** : 98.61%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {690V} Compare Against Peer CEC Listings?

CEC efficiency rank (#48), 1,020-1,500 V MPPT tracking, and panel fit for DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {690V}.

Operating at 690 V, 3-phase, DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {690V} converts DC array energy at 98.61% CEC weighted efficiency (top 2.1%; higher than 97.9% of peers) with a 1,500 V max DC input and 929.777 A max input current for NEC 690.7 string safety. Compare this 1,146,100 W grid-tied PV inverter directly with SINENG ELECTRIC CO LTD: EH-1250-HB-UD-US {690V} (1,250,740 W). Commercial 690 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (690V) or NEC 705.11 supply-side tap.

## Where Does DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {690V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {690V} at 1,146,100 W continuous AC output. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

## What Dataset Percentiles Define DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {690V}?

Dataset percentiles comparing DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {690V} against 2,343 certified grid-support inverters nationwide. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

## What Do the Dataset Ranks Show for DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {690V}?

Engineering highlights for DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {690V} covering efficiency, parallel Cu feeders feeder, and panel compatibility.

Eff #48 / 2,343

### 98.61% CEC Weighted Efficiency

+0.44 pts vs the 98.17% 690 V median; overall power rank #154 (1,146,100 W, top 6.6%; higher than 93.4% of peers).

NEC 705.12 Check

### 1,200 A Required Backfeed OCPD

125% x 959.0 A = 1198.8 A -> 1,200 A standard OCPD using parallel Cu feeders (75 C).

MPPT Window

### 1,020 V - 1,500 V (Max 1,500 V DC)

Tracking span of 480.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

### Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 690 V, 3-phase switchgear (200A Bus / 200A Main (690V) to 1,200A Bus / 1,200A Main (690V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 1146100.0W / 690 V 3-phase -> 959.0 A | Breaker >= 1.25 * 959.0 = 1198.8 A -> 1,200 A

CEC Inverters.csv for DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {690V}: Paco=1146100.0 W, Vac=690 V, Vdcmax=1500.0 V, Eff=98.61%.

**Result:** Min 1,200 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (690V): Supply-Side Tap (705.11) / Dedicated Switchboard.

## What Are the Published CEC Specifications for DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {690V}?

California Energy Commission Solar Equipment List parameters for DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {690V} (grid-tied PV inverter) interconnection.

Official California Energy Commission (NREL SAM) test parameters for DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {690V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 1,146,100 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 690 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 1,500 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 1,020 V - 1,500 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 929.777 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 98.61% | Calculated AC/DC conversion ratio from CEC test protocol |
| **Inverter Topology** | Hybrid: No (Grid-Tied PV) | CEC Solar Equipment List grid-support certification |

## What Switchgear Limits Apply to DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {690V} (690 V, 3-phase)?

Panelboard and switchgear backfeed allowances for DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {690V} (1,200 A OCPD). Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Evaluates DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {690V} (1200 A required OCPD at 690 V, 3-phase) across standard distribution busbars.

| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **200A Bus / 200A Main (690V)** | 40 A | 1,200 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **400A Bus / 400A Main (690V)** | 80 A | 1,200 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **600A Bus / 600A Main (690V)** | 120 A | 1,200 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **800A Bus / 800A Main (690V)** | 160 A | 1,200 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| **1,200A Bus / 1,200A Main (690V)** | 240 A | 1,200 A | Supply-Side Tap (705.11) / Dedicated Switchboard |

## Which CEC PV Module Strings Pair With DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {690V}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {690V}. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Sampled CEC PV modules aligned within 1020.0-1500.0 V MPPT and 1500.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 24 to 26 panels | 15.34 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 31 to 35 panels | 15.4 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 30 to 33 panels | 14.03 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 36 panels (fixed) | 7.2 kW |

## Which Competing Grid-Support Inverters Compare to DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {690V}?

Four alternative CEC inverters matched to DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {690V} (1,146,100 W AC), led by SINENG ELECTRIC CO LTD: EH-1250-HB-UD-US {690V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**SINENG ELECTRIC CO LTD: EH-1250-HB-UD-US {690V}**](https://epri-peac.com/solar-equipment/inverters/sineng-electric-co-ltd/sineng-electric-co-ltd-eh-1250-hb-ud-us-690v/) SINENG ELECTRIC CO LTD | 1,250,740 W | +104640 W | 690.0 V | 1500.0 V | 98.05% |
| [**INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1800TL U B690 {690V}**](https://epri-peac.com/solar-equipment/inverters/ingeteam-power-technology-sa/ingeteam-power-technology-sa-ingecon-sun-1800tl-u-b690-690v/) INGETEAM POWER TECHNOLOGY SA | 1,300,644 W | +154544 W | 690.0 V | 1200.0 V | 97.34% |
| [**Power Electronics: FS1275CU15 {690V}**](https://epri-peac.com/solar-equipment/inverters/power-electronics/power-electronics-fs1275cu15-690v/) Power Electronics | 1,389,080 W | +242980 W | 690.0 V | 1200.0 V | 97.72% |
| [**EPC Power Corp: 50-100100 {690V}**](https://epri-peac.com/solar-equipment/inverters/epc-power-corp/epc-power-corp-50-100100-690v/) EPC Power Corp | 1,499,860 W | +353760 W | 690.0 V | 1250.0 V | 96.33% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {690V}?

Check DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {690V} (1,146,100 W AC, 1,200 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 690 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (690V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,500 V DC on DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {690V}.

### DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {690V} Panel & Wire Spec

Size 75 C copper conductors at parallel Cu feeders on a 1,200 A OCPD breaker (959.0 A continuous).

### Alternative Inverter Comparison

Compare efficiency (98.61%) and MPPT window (1,020-1,500 V) directly against SINENG ELECTRIC CO LTD: EH-1250-HB-UD-US {690V} (1,250,740 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {690V} by DYNAPOWER COMPANY LLC covering breaker sizing, MPPT limits, and 690 V, 3-phase interconnection.

### What breaker and wire size does DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {690V} require?

At 1,146,100 W continuous AC (690 V, 3-phase), continuous current is 959.0 A; 125% NEC 690.8/705.12 sizing requires a 1,200 A breaker and parallel Cu feeders (75 C) wire.

### What commercial switchgear or feeder sizing does DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {690V} require?

At 1,146,100 W AC and 690 V, 3-phase, continuous line current is 959.0 A, requiring a 1,200 A OCPD and 1,200A Bus / 1,200A Main (690V) or NEC 705.11 interconnection.

### How does DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {690V} compare to SINENG ELECTRIC CO LTD: EH-1250-HB-UD-US {690V}?

DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {690V} delivers 1,146,100 W AC at 98.61% CEC efficiency with a 1,500 V DC ceiling, while SINENG ELECTRIC CO LTD: EH-1250-HB-UD-US {690V} outputs 1,250,740 W at 690 V, 3-phase.

## Related Pages

Explore DYNAPOWER COMPANY LLC hardware, SINENG ELECTRIC CO LTD: EH-1250-HB-UD-US {690V}, utility rates, and NEC 705.12 sizing calculators alongside DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {690V}.

[All DYNAPOWER COMPANY LLC Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/dynapower-company-llc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From DYNAPOWER COMPANY LLC

- [All DYNAPOWER COMPANY LLC Specs](https://epri-peac.com/solar-equipment/brands/dynapower-company-llc/)
- [DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {690V}](https://epri-peac.com/solar-equipment/inverters/dynapower-company-llc/dynapower-company-llc-cps-2500-gen5-690v/)
- [DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {600V}](https://epri-peac.com/solar-equipment/inverters/dynapower-company-llc/dynapower-company-llc-cps-1500-gen4-600v/)
- [DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {415V}](https://epri-peac.com/solar-equipment/inverters/dynapower-company-llc/dynapower-company-llc-cps-2500-gen5-415v/)
- [DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V}](https://epri-peac.com/solar-equipment/inverters/dynapower-company-llc/dynapower-company-llc-cps-1250-gen5-800v/)