title: "Chilicon Power LLC Inverter (289W)"
url: https://epri-peac.com/solar-equipment/inverters/chilicon-power-llc/chilicon-power-llc-cp-250e-60-72-208-240-mc4-240v/
description: "CEC specs for Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V}: 289W AC, 240V, 15A OCPD, and NEC 705.12 checks. Source-verified US engineering data."
---

CEC Grid-Support Inverter

# Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V} — CEC Inverter Specifications

Manufacturer: [**Chilicon Power LLC**](https://epri-peac.com/solar-equipment/brands/chilicon-power-llc/) Registry: **CEC Verified Engineering Specification**

Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V} outputs 289 W AC at 240 V (1.2 A continuous, 15 A OCPD), ranking #2,190 of 2,343 CEC inverters at 95.41% efficiency with a 28-32 V MPPT window and 32 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 289 W

- **AC Voltage** : 240 V

- **Min PV Breaker** : 15 A (14 AWG Cu)

- **CEC Efficiency** : 95.41%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V} Compare Against Peer CEC Listings?

How Chilicon Power LLC Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V} compares on 95.41% efficiency, MPPT span, and 120% busbar interconnection.

Chilicon Power LLC certifies Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V} (grid-tied PV inverter, listed since 2020-02-11) at 289 W AC (5,487 W below the 5,776 W 240 V median). Its 32 V DC ceiling pairs with an MPPT window of 28-32 V (span 4.0 V). Under NEC 690.8/705.12, 125% sizing demands 14 AWG Cu conductors on a 15 A OCPD.

## Where Does Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V} Fall Across Listed CEC Models?

Position of Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V} (289 W AC) relative to the 7,680 W CEC median inverter.

## What Dataset Percentiles Define Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V}?

Percentile placement of Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V} across AC power class, conversion efficiency, and backfeed breaker size.

## What Do the Dataset Ranks Show for Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V}.

Eff #2,190 / 2,343

### 95.41% CEC Weighted Efficiency

-1.27 pts vs the 96.68% 240 V median; overall power rank #2,296 (289 W, below CEC median; higher than 2.0% of peers).

NEC 705.12 Check

### 15 A Required Backfeed OCPD

125% x 1.2 A = 1.5 A -> 15 A standard OCPD using 14 AWG Cu (75 C).

MPPT Window

### 28 V - 32 V (Max 32 V DC)

Tracking span of 4.0 V; listed since 2020-02-11 (grid-tied PV inverter).

Panel Fit (240V)

### PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 289.0W / 240 V -> 1.2 A | Breaker >= 1.25 * 1.2 = 1.5 A -> 15 A

CEC Inverters.csv for Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V}: Paco=289.0 W, Vac=240 V, Vdcmax=32.0 V, Eff=95.41%.

**Result:** Min 15 A breaker & 14 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

## What Are the Published CEC Specifications for Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V}.

Official California Energy Commission (NREL SAM) test parameters for Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 289 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 32 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 28 V - 32 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 10.0967 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 95.41% | Calculated AC/DC conversion ratio from CEC test protocol |
| **CEC Listing Date & Hybrid** | 2020-02-11 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |

## Can a Residential Panel Meet 120% Busbar Limits for Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V}?

Check whether Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V} (15 A breaker) fits without main breaker derate or supply-side taps.

Evaluates Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V} (15 A required OCPD at 240 V) across standard distribution busbars.

| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **100A Bus / 100A Main** | 20 A | 15 A | PASS (120% Rule) |
| **150A Bus / 150A Main** | 30 A | 15 A | PASS (120% Rule) |
| **200A Bus / 200A Main** | 40 A | 15 A | PASS (120% Rule) |
| **200A Bus / 175A Main** | 65 A | 15 A | PASS (120% Rule) |
| **225A Bus / 200A Main** | 70 A | 15 A | PASS (120% Rule) |

## Which Competing Grid-Support Inverters Compare to Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V}?

Alternative CEC inverters comparable to Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V}, including Aptos Solar Technology LLC: MAC-400 {240V} (382 W) at 240 V.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Aptos Solar Technology LLC: MAC-400 {240V}**](https://epri-peac.com/solar-equipment/inverters/aptos-solar-technology-llc/aptos-solar-technology-llc-mac-400-240v/) Aptos Solar Technology LLC | 382 W | +94 W | 240.0 V | 48.0 V | 96.52% |
| [**Aptos Solar Technology LLC: MAC-400R {240V}**](https://epri-peac.com/solar-equipment/inverters/aptos-solar-technology-llc/aptos-solar-technology-llc-mac-400r-240v/) Aptos Solar Technology LLC | 382 W | +94 W | 240.0 V | 48.0 V | 96.52% |
| [**Altenergy Power System Inc: YC600 {240V}**](https://epri-peac.com/solar-equipment/inverters/altenergy-power-system-inc/altenergy-power-system-inc-yc600-240v/) Altenergy Power System Inc | 550 W | +261 W | 240.0 V | 45.0 V | 96.51% |
| [**Cherry Solution Co Ltd: CMI-600S-SA {240V}**](https://epri-peac.com/solar-equipment/inverters/cherry-solution-co-ltd/cherry-solution-co-ltd-cmi-600s-sa-240v/) Cherry Solution Co Ltd | 604 W | +315 W | 240.0 V | 50.0 V | 96.12% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V}?

Check Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V} (289 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 32 V DC on Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V}.

### Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V} Panel & Wire Spec

Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (1.2 A continuous).

### Alternative Inverter Comparison

Compare efficiency (95.41%) and MPPT window (28-32 V) directly against Aptos Solar Technology LLC: MAC-400 {240V} (382 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V} by Chilicon Power LLC covering breaker sizing, MPPT limits, and 240 V interconnection.

### What breaker and wire size does Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V} require?

At 289 W continuous AC (240 V), continuous current is 1.2 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.

### Does Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 15 A at 240 V means PASS (120% Rule).

### How does Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V} compare to Aptos Solar Technology LLC: MAC-400 {240V}?

Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V} delivers 289 W AC at 95.41% CEC efficiency with a 32 V DC ceiling, while Aptos Solar Technology LLC: MAC-400 {240V} outputs 382 W at 240 V.

## Related Pages

Explore Chilicon Power LLC hardware, Aptos Solar Technology LLC: MAC-400 {240V}, utility rates, and NEC 705.12 sizing calculators alongside Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V}.

[All Chilicon Power LLC Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/chilicon-power-llc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Chilicon Power LLC

- [All Chilicon Power LLC Specs](https://epri-peac.com/solar-equipment/brands/chilicon-power-llc/)
- [Chilicon Power LLC: CP-720-60/72/96-208/240-MC4 {208V}](https://epri-peac.com/solar-equipment/inverters/chilicon-power-llc/chilicon-power-llc-cp-720-60-72-96-208-240-mc4-208v/)
- [Chilicon Power LLC: CP-720-60/72/96-208/240-MC4 {240V}](https://epri-peac.com/solar-equipment/inverters/chilicon-power-llc/chilicon-power-llc-cp-720-60-72-96-208-240-mc4-240v/)
- [Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {208V}](https://epri-peac.com/solar-equipment/inverters/chilicon-power-llc/chilicon-power-llc-cp-250e-60-72-208-240-mc4-208v/)