title: "Base Power Inc: MIN 10000TL-XH-US Inverter (10,082W)"
url: https://epri-peac.com/solar-equipment/inverters/base-power-inc/base-power-inc-min-10000tl-xh-us-240v/
description: "CEC specs for Base Power Inc: MIN 10000TL-XH-US {240V}: 10,082W AC, 240V, 60A OCPD, and NEC 705.12 checks. Verified US government and CEC engineering data."
---

CEC Grid-Support Inverter

# Base Power Inc: MIN 10000TL-XH-US {240V} — CEC Inverter Specifications

Manufacturer: [**Base Power Inc**](https://epri-peac.com/solar-equipment/brands/base-power-inc/) Registry: **CEC Verified Engineering Specification**

Base Power Inc: MIN 10000TL-XH-US {240V} outputs 10,082 W AC at 240 V (42.0 A continuous, 60 A OCPD), ranking #506 of 2,343 CEC inverters at 97.61% efficiency with a 250-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 10,082 W

- **AC Voltage** : 240 V

- **Min PV Breaker** : 60 A (6 AWG Cu)

- **CEC Efficiency** : 97.61%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Base Power Inc: MIN 10000TL-XH-US {240V} Compare Against Peer CEC Listings?

Breaker sizing (60 A), 6 AWG Cu wire rules, and DC input limits for Base Power Inc: MIN 10000TL-XH-US {240V}.

Classified as a hybrid battery-capable inverter (active in CEC directory), Base Power Inc: MIN 10000TL-XH-US {240V} requires 52.5 A design capacity -> 60 A breaker using 6 AWG Cu copper at 75 C terminals. Weighted efficiency sits at 97.61% (+0.79 pts vs overall CEC median) across 2,343 CEC models, while its 60 a backfeed breaker exceeds a 200a/200a panel's 40 a ceiling, requiring a 175 a main derate, 225 a busbar, or nec 705.11 tap.

## Where Does Base Power Inc: MIN 10000TL-XH-US {240V} Fall Across Listed CEC Models?

Output power comparison showing where Base Power Inc: MIN 10000TL-XH-US {240V} sits among all 2,343 CEC-listed grid-support inverters.

## What Dataset Percentiles Define Base Power Inc: MIN 10000TL-XH-US {240V}?

Relative ranking of Base Power Inc: MIN 10000TL-XH-US {240V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

## What Do the Dataset Ranks Show for Base Power Inc: MIN 10000TL-XH-US {240V}?

Snapshot of Base Power Inc: MIN 10000TL-XH-US {240V} efficiency rank (#506), OCPD breaker size, MPPT span, and busbar verdict.

Eff #506 / 2,343

### 97.61% CEC Weighted Efficiency

+0.93 pts vs the 96.68% 240 V median; overall power rank #865 (10,082 W, top 37.0%; higher than 63.0% of peers).

NEC 705.12 Check

### 60 A Required Backfeed OCPD

125% x 42.0 A = 52.5 A -> 60 A standard OCPD using 6 AWG Cu (75 C).

MPPT Window

### 250 V - 480 V (Max 480 V DC)

Tracking span of 230.0 V; active in CEC directory (hybrid battery-capable inverter).

Panel Fit (240V)

### Needs Derate / Tap 705.11

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 10082.0W / 240 V -> 42.0 A | Breaker >= 1.25 * 42.0 = 52.5 A -> 60 A

CEC Inverters.csv for Base Power Inc: MIN 10000TL-XH-US {240V}: Paco=10082.0 W, Vac=240 V, Vdcmax=480.0 V, Eff=97.61%.

**Result:** Min 60 A breaker & 6 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.

## What Are the Published CEC Specifications for Base Power Inc: MIN 10000TL-XH-US {240V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Base Power Inc: MIN 10000TL-XH-US {240V}.

Official California Energy Commission (NREL SAM) test parameters for Base Power Inc: MIN 10000TL-XH-US {240V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 10,082 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 480 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 250 V - 480 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 27.1802 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 97.61% | Calculated AC/DC conversion ratio from CEC test protocol |
| **Inverter Topology** | Hybrid: Yes (Battery Capable) | CEC Solar Equipment List grid-support certification |

## Can a Residential Panel Meet 120% Busbar Limits for Base Power Inc: MIN 10000TL-XH-US {240V}?

NEC 705.12(B)(3)(2) backfeed compliance table for Base Power Inc: MIN 10000TL-XH-US {240V} at 240 V.

Evaluates Base Power Inc: MIN 10000TL-XH-US {240V} (60 A required OCPD at 240 V) across standard distribution busbars.

| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **100A Bus / 100A Main** | 20 A | 60 A | Needs Derate / Tap 705.11 |
| **150A Bus / 150A Main** | 30 A | 60 A | Needs Derate / Tap 705.11 |
| **200A Bus / 200A Main** | 40 A | 60 A | Needs Derate / Tap 705.11 |
| **200A Bus / 175A Main** | 65 A | 60 A | PASS (120% Rule) |
| **225A Bus / 200A Main** | 70 A | 60 A | PASS (120% Rule) |

## Which CEC PV Module Strings Pair With Base Power Inc: MIN 10000TL-XH-US {240V}?

Minimum and maximum series solar module strings fitting Base Power Inc: MIN 10000TL-XH-US {240V} MPPT and 480 V limits.

Sampled CEC PV modules aligned within 250.0-480.0 V MPPT and 480.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 6 to 8 panels | 4.72 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 8 to 11 panels | 4.84 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 8 to 10 panels | 4.25 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 9 to 11 panels | 2.2 kW |

## Which Competing Grid-Support Inverters Compare to Base Power Inc: MIN 10000TL-XH-US {240V}?

Peer 240 V CEC inverters near 10,082 W AC output such as Amensolar Ess Co Ltd: N3H-X100-US {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Amensolar Ess Co Ltd: N3H-X100-US {240V}**](https://epri-peac.com/solar-equipment/inverters/amensolar-ess-co-ltd/amensolar-ess-co-ltd-n3h-x100-us-240v/) Amensolar Ess Co Ltd | 10,177 W | +95 W | 240.0 V | 430.0 V | 97.15% |
| [**Amensolar Ess Co Ltd: N3H-X10US {240V}**](https://epri-peac.com/solar-equipment/inverters/amensolar-ess-co-ltd/amensolar-ess-co-ltd-n3h-x10us-240v/) Amensolar Ess Co Ltd | 10,177 W | +95 W | 240.0 V | 430.0 V | 97.15% |
| [**Delta Electronics: E10_BDI {240V}**](https://epri-peac.com/solar-equipment/inverters/delta-electronics/delta-electronics-e10-bdi-240v/) Delta Electronics | 9,674 W | -408 W | 240.0 V | 480.0 V | 97.21% |
| [**Delta Electronics: E10-TL-US {240V}**](https://epri-peac.com/solar-equipment/inverters/delta-electronics/delta-electronics-e10-tl-us-240v/) Delta Electronics | 9,674 W | -408 W | 240.0 V | 480.0 V | 97.21% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Base Power Inc: MIN 10000TL-XH-US {240V}?

Check Base Power Inc: MIN 10000TL-XH-US {240V} (10,082 W AC, 60 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Its 60 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on Base Power Inc: MIN 10000TL-XH-US {240V}.

### Base Power Inc: MIN 10000TL-XH-US {240V} Panel & Wire Spec

Size 75 C copper conductors at 6 AWG Cu on a 60 A OCPD breaker (42.0 A continuous).

### Alternative Inverter Comparison

Compare efficiency (97.61%) and MPPT window (250-480 V) directly against Amensolar Ess Co Ltd: N3H-X100-US {240V} (10,177 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Base Power Inc: MIN 10000TL-XH-US {240V} by Base Power Inc covering breaker sizing, MPPT limits, and 240 V interconnection.

### What breaker and wire size does Base Power Inc: MIN 10000TL-XH-US {240V} require?

At 10,082 W continuous AC (240 V), continuous current is 42.0 A; 125% NEC 690.8/705.12 sizing requires a 60 A breaker and 6 AWG Cu (75 C) wire.

### Does Base Power Inc: MIN 10000TL-XH-US {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 60 A at 240 V means Needs Derate / Tap 705.11.

### How does Base Power Inc: MIN 10000TL-XH-US {240V} compare to Amensolar Ess Co Ltd: N3H-X100-US {240V}?

Base Power Inc: MIN 10000TL-XH-US {240V} delivers 10,082 W AC at 97.61% CEC efficiency with a 480 V DC ceiling, while Amensolar Ess Co Ltd: N3H-X100-US {240V} outputs 10,177 W at 240 V.

## Related Pages

Explore Base Power Inc hardware, Amensolar Ess Co Ltd: N3H-X100-US {240V}, utility rates, and NEC 705.12 sizing calculators alongside Base Power Inc: MIN 10000TL-XH-US {240V}.

[All Base Power Inc Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/base-power-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Base Power Inc

- [All Base Power Inc Specs](https://epri-peac.com/solar-equipment/brands/base-power-inc/)
- [Base Power Inc: MIN 11400TL-XH-US {240V}](https://epri-peac.com/solar-equipment/inverters/base-power-inc/base-power-inc-min-11400tl-xh-us-240v/)
- [Base Power Inc: MIN 9000TL-XH-US {240V}](https://epri-peac.com/solar-equipment/inverters/base-power-inc/base-power-inc-min-9000tl-xh-us-240v/)
- [Base Power Inc: MIN 8200TL-XH-US {240V}](https://epri-peac.com/solar-equipment/inverters/base-power-inc/base-power-inc-min-8200tl-xh-us-240v/)
- [Base Power Inc: MIN 7600TL-XH-US {240V}](https://epri-peac.com/solar-equipment/inverters/base-power-inc/base-power-inc-min-7600tl-xh-us-240v/)
- [Base Power Inc: MIN 6000TL-XH-US {240V}](https://epri-peac.com/solar-equipment/inverters/base-power-inc/base-power-inc-min-6000tl-xh-us-240v/)